263 research outputs found
A computerized Langmuir probe system
For low pressure plasmas it is important to record entire single or double Langmuir probe characteristics accurately. For plasmas with a depleted high energy tail, the accuracy of the recorded ion current plays a critical role in determining the electron temperature. Even for high density Maxwellian distributions, it is necessary to accurately model the ion current to obtain the correct electron density. Since the electron and ion current saturation values are, at best, orders of magnitude apart, a single current sensing resistor cannot provide the required resolution to accurately record these values. We present an automated, personal computer based data acquisition system for the determination of fundamental plasma properties in low pressure plasmas. The system is designed for single and double Langmuir probes, whose characteristics can be recorded over a bias voltage range of ±70 V with 12 bit resolution. The current flowing through the probes can be recorded within the range of 5 nA–100 mA. The use of a transimpedance amplifier for current sensing eliminates the requirement for traditional current sensing resistors and hence the need to correct the raw data. The large current recording range is realized through the use of a real time gain switching system in the negative feedback loop of the transimpedance amplifier
Saturation of a spin 1/2 particle by generalized Local control
We show how to apply a generalization of Local control design to the problem
of saturation of a spin 1/2 particle by magnetic fields in Nuclear Magnetic
Resonance. The generalization of local or Lyapunov control arises from the fact
that the derivative of the Lyapunov function does not depend explicitly on the
control field. The second derivative is used to determine the local control
field. We compare the efficiency of this approach with respect to the
time-optimal solution which has been recently derived using geometric methods.Comment: 12 pages, 4 figures, submitted to new journal of physics (2011
T2 Values of Posterior Horns of Knee Menisci in Asymptomatic Subjects
[[abstract]]Purpose: The magnetic resonance (MR) T2 value of cartilage is a reliable indicator of tissue properties and therefore may be used as an objective diagnostic tool in early meniscal degeneration. The purpose of this study was to investigate age, gender, location, and zonal differences in MR T2 value of the posterior horns of knee menisci in asymptomatic subjects. Methods: Sixty asymptomatic volunteers (30 men and 30 women) were enrolled and divided into three different age groups: 20–34, 35–49 and 50–70 years. The inclusion criteria were BMI<30 kg/cm2, normalized Western Ontario and McMaster Universities (WOMAC) pain score of zero, and no evidence of meniscal and ligamentous abnormalities on routine knee MR imaging. The T2 values were measured on images acquired with a T2-weighted fat-suppressed turbo spin-echo sequence at 3T. Results: The mean T2 values in both medial and lateral menisci for the 20–34, 35–49, and 50–70 age groups were 9.94 msec±0.94, 10.73 msec±1.55, and 12.36 msec±2.27, respectively, for women and 9.17 msec±0.74, 9.64 msec±0.67, and 10.95 msec±1.33, respectively, for men. The T2 values were significantly higher in the 50–70 age group than the 20–34 age group (P<0.001) and in women than in men (P = 0.001, 0.004, and 0.049 for each respective age group). T2 values were significantly higher in medial menisci than in lateral menisci only in women age 50–70 (3.33 msec, P = 0.006) and in the white zone and red/white zone of the 50–70 and 35–49 age groups than that of the 20–34 age group (2.47, 1.02; 2.77, 1.16 msec, respectively, all P<0.01). Conclusion: The MR T2 values of the posterior meniscal horns increase with increasing age in women and are higher in women than in men. The age-related rise of T2 values appears to be more severe in medial menisci than in lateral menisci. Differences exist in the white zone and red/white zone.[[incitationindex]]SCI[[booktype]]電子
Structural brain changes in patients with Huntington's disease participating in a randomized, double-blind, placebo-controlled trial of ethyl-eicosapentaenoic acid
Recommended from our members
Qualitative and Quantitative MR Imaging of the Cartilaginous Endplate: A Review
The cartilaginous endplate (CEP) plays a pivotal role in facilitating the supply of nutrients and, transport of metabolic waste, as well as providing mechanical support for the intervertebral disc (IVD). Recent technological advances have led to a surge in MR imaging studies focused on the CEP. This article describes the anatomy and functions of the CEP as well as MRI techniques for both qualitative and quantitative assessment of the CEP. Effective CEP MR imaging sequences require two key features: high spatial resolution and relatively short echo time. High spatial resolution spoiled gradient echo (SPGR) and ultrashort echo time (UTE) sequences, fulfilling these requirements, are the basis for most of the sequences employed in CEP imaging. This article reviews existing sequences for qualitative CEP imaging, such as the fat-suppressed SPGR and UTE, dual-echo subtraction UTE, inversion recovery prepared and fat-suppressed UTE, and dual inversion recovery prepared UTE sequences. These sequences are employed together with other techniques for quantitative CEP imaging, including measurements of T2*, T2, T1, T1ρ, magnetization transfer, perfusion, and diffusion tensor parameters. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2
PB.22. Does mammographic compression force at breast screening influence the likelihood of subsequent screening attendance?
Recommended from our members
Myelin water quantification in multiple sclerosis using short repetition time adiabatic inversion recovery prepared-fast spin echo (STAIR-FSE) imaging
BackgroundMyelin water imaging (MWI) is a myelin-specific technique, which has great potential for the assessment of demyelination and remyelination. This study develops a new MWI method, which employs a short repetition time adiabatic inversion recovery (STAIR) technique in combination with a commonly used fast spin echo (FSE) sequence and provides quantification of myelin water (MW) fractions.MethodWhole-brain MWI was performed using the short repetition time adiabatic inversion recovery prepared-fast spin echo (STAIR-FSE) technique on eight healthy volunteers (mean age: 38±14 years, four-males) and seven patients with multiple sclerosis (MS) (mean age: 53.7±8.7 years, two-males) on a 3T clinical magnetic resonance imaging scanner. To facilitate the quantification of apparent myelin water fraction (aMWF), a proton density-weighted FSE was also used during the scans to allow total water imaging. The aMWF measurements of MS lesions and normal-appearing white matter (NAWM) regions in MS patients were compared with those measured in normal white matter (NWM) regions in healthy volunteers. Both the analysis of variance (ANOVA) test and paired comparison were performed for the comparison.ResultsThe MW in the whole-brain was selectively imaged and quantified using the STAIR-FSE technique in all participants. MS lesions showed much lower signal intensities than NAWM in the STAIR-FSE images. ANOVA analysis revealed a significant difference in the aMWF measurements between the three groups. Moreover, the aMWF measurements in MS lesions were significantly lower than those in both NWM of healthy volunteers and NAWM of MS patients. Lower aMWF measurements in NAWM were also found in comparison with those in NWM.ConclusionsThe STAIR-FSE technique is capable of measuring aMWF values for the indirect detection of myelin loss in MS, thus facilitating clinical translation of whole brain MWI and quantification, which show great potential for the detection and evaluation of changes in myelin in the brain of patients with MS for future larger cohort studies
Detection of maturity and ligament injury using magic angle directional imaging
Purpose: To investigate whether magnetic field–related anisotropies of collagen may be correlated with postmortem findings in animal models. Methods: Optimized scan planning and new MRI data‐processing methods were proposed and analyzed using Monte Carlo simulations. Six caprine and 10 canine knees were scanned at various orientations to the main magnetic field. Image intensities in segmented voxels were used to compute the orientation vectors of the collagen fibers. Vector field and tractography plots were computed. The Alignment Index was defined as a measure of orientation distribution. The knees were subsequently assessed by a specialist orthopedic veterinarian, who gave a pathological diagnosis after having dissected and photographed the joints. Results: Using 50% less scans than reported previously can lead to robust calculation of fiber orientations in the presence of noise, with much higher accuracy. The 6 caprine knees were found to range from very immature ( 3 years). Mature specimens exhibited significantly more aligned collagen fibers in their patella tendons compared with the immature ones. In 2 of the 10 canine knees scanned, partial cranial caudal ligament tears were identified from MRI and subsequently confirmed with encouragingly high consistency of tractography, Alignment Index, and dissection results. Conclusion: This method can be used to detect injury such as partial ligament tears, and to visualize maturity‐related changes in the collagen structure of tendons. It can provide the basis for new, noninvasive diagnostic tools in combination with new scanner configurations that allow less‐restricted field orientations
- …
