2,964 research outputs found

    ATLAS RPC Quality Assurance results at INFN Lecce

    Get PDF
    The main results of the quality assurance tests performed on the Resistive Plate Chamber used by the ATLAS experiment at LHC as muon trigger chambers are reported and discussed. Since July 2004, about 270 RPC units has been certified at INFN Lecce site and delivered to CERN, for being integrated in the final muon station of the ATLAS barrel region. We show the key RPC characteristics which qualify the performance of this detector technology as muon trigger chamber in the harsh LHC enviroments. These are dark current, chamber efficiency, noise rate, gas volume tomography, and gas leakage.Comment: Comments: 6 pages, 1 table, 9 figures Proceedings of XXV Physics in Collision-Prague, Czech Republic, 6-9 July 200

    ATLAS RPC Cosmic Ray Teststand at INFN Lecce

    Full text link
    We describe the design and functionality of the cosmic ray teststand built at INFN Lecce for ATLAS RPC quality control assurance.Comment: XXIV Physics in Collisions Conference (PIC04), Boston, USA, June 2004, 3 pages, LaTex, 2 eps figures. MONP0

    Ageing test of the ATLAS RPCs at X5-GIF

    Full text link
    An ageing test of three ATLAS production RPC stations is in course at X5-GIF, the CERN irradiation facility. The chamber efficiencies are monitored using cosmic rays triggered by a scintillator hodoscope. Higher statistics measurements are made when the X5 muon beam is available. We report here the measurements of the efficiency versus operating voltage at different source intensities, up to a maximum counting rate of about 700Hz/cm^2. We describe the performance of the chambers during the test up to an overall ageing of 4 ATLAS equivalent years corresponding to an integrated charge of 0.12C/cm^2, including a safety factor of 5.Comment: 4 pages. Presented at the VII Workshop on Resistive Plate Chambers and Related Detectors; Clermont-Ferrand October 20th-22nd, 200

    Final-sate radiation in electron-positron annihilation into a pion pair

    Full text link
    The process of e+ee^+e^- annihilation into a π+π\pi^+\pi^- pair with radiation of a photon is considered. The amplitude of the reaction e+eπ+πγe^+e^-\to\pi^+\pi^-\gamma consists of the model independent initial-state radiation (ISR) and model-dependent final-state radiation (FSR). The general structure of the FSR tensor is constructed from Lorentz covariance, gauge invariance and discrete symmetries in terms of the three invariant functions. To calculate these functions we apply Chiral Perturbation Theory (ChPT) with vector and axial-vector mesons. The contribution of e+eπ+πγe^+e^-\to\pi^+\pi^-\gamma process to the muon anomalous magnetic moment is evaluated, and results are compared with the dominant contribution in the framework of a hybrid model, consisting of VMD and point-like scalar eletrodynamics. The developed approach allows us also to calculate the π+π\pi^+\pi^- charge asymmetry.Comment: 21 pages, 8 figure

    COSMOGRAIL: the COSmological MOnitoring of GRAvItational Lenses XIII: Time delays and 9-yr optical monitoring of the lensed quasar RX J1131-1231

    Full text link
    We present the results from nine years of optically monitoring the gravitationally lensed z=0.658 quasar RX J1131-1231. The R-band light curves of the four individual images of the quasar were obtained using deconvolution photometry for a total of 707 epochs. Several sharp quasar variability features strongly constrain the time delays between the quasar images. Using three different numerical techniques, we measure these delays for all possible pairs of quasar images while always processing the four light curves simultaneously. For all three methods, the delays between the three close images A, B, and C are compatible with being 0, while we measure the delay of image D to be 91 days, with a fractional uncertainty of 1.5% (1 sigma), including systematic errors. Our analysis of random and systematic errors accounts in a realistic way for the observed quasar variability, fluctuating microlensing magnification over a broad range of temporal scales, noise properties, and seasonal gaps. Finally, we find that our time-delay measurement methods yield compatible results when applied to subsets of the data.Comment: 11 pages, 9 figures, minor additions to the text only, techniques and results remain unchanged, A&A in pres

    The Air Microwave Yield (AMY) experiment - A laboratory measurement of the microwave emission from extensive air showers

    Full text link
    The AMY experiment aims to measure the microwave bremsstrahlung radiation (MBR) emitted by air-showers secondary electrons accelerating in collisions with neutral molecules of the atmosphere. The measurements are performed using a beam of 510 MeV electrons at the Beam Test Facility (BTF) of Frascati INFN National Laboratories. The goal of the AMY experiment is to measure in laboratory conditions the yield and the spectrum of the GHz emission in the frequency range between 1 and 20 GHz. The final purpose is to characterise the process to be used in a next generation detectors of ultra-high energy cosmic rays. A description of the experimental setup and the first results are presented.Comment: 3 pages -- EPS-HEP'13 European Physical Society Conference on High Energy Physics (July, 18-24, 2013) at Stockholm, Swede

    Effect of a Short-Course Treatment with Synbiotics on Plasma p-Cresol Concentration in Kidney Transplant Recipients.

    Get PDF
    We evaluated whether a short-term course with synbiotics may lower plasma p-Cresol concentrations in kidney transplant patients (KTRs) who accumulate this uremic toxin both because of increased production by their dysbiotic gut microbiome and because of reduced elimination by the transplanted kidneys. METHODS: Thirty-six KTRs (29 males, mean age 49.6 ± 9.1 years) with transplant vintage > 12 months, stable graft function, and no episode of acute rejection or infection in the last 3 months were enrolled in this single-center, parallel-group, double-blinded, randomized (2:1 synbiotic to placebo) study. Synbiotic (Probinul Neutro, CadiGroup, Rome, Italy) or placebo was taken at home for 30 days, as 5 g powder packets dissolved in water three times a day far from meals. The main outcome measure was the decrease in total plasma p-Cresol measured by high-performance liquid chromatography at baseline and after 15 and 30 days of placebo or synbiotic treatment. RESULTS: After 15 and 30 days of treatment, plasma p-Cresol decreased by 40% and 33% from baseline (both p < 0.05), respectively, in the synbiotic group, whereas it remained stable in the placebo group. After 30 days of treatment, no significant change was observed in either group in renal function, glycemia, plasma lipids, or albumin concentration. Treatment was well tolerated and did not induce any change in stool characteristics. CONCLUSION: The results of this pilot study suggest that treatment with synbiotics may be effective to lower plasma p-Cresol concentrations in KTRs. Prospective larger scale, longer term studies are needed to establish whether cardiovascular prognosis could also be improved with this nutritional intervention

    Measuring the hadronic cross section via radiative return

    Get PDF
    Recently it has been demonstrated that particle factories, such as DAPHNE and PEP-II, operating at fixed center-of-mass energies, are able to measure hadronic cross sections as a function of the hadronic system energy using the raditive return. This paper is an experimental overview of the progress in this aera. Preliminary results from KLOE for the process e+e- -> \rho \gamma -> \pi+\pi-\gamma and a fit to the pion form factor are presented. Some first results from the BABAR collaboration are also shown.Comment: Invited talk presented at RADCOR/Loops and Legs 2002, Kloster Banz/Germany, September 8-13 2002, 6 pages, 2 Figures; v1: references added, typos correcte

    Measurement of hadronic cross section and preliminary results on the pion form factor using the radiative return at DAPHNE

    Get PDF
    In the fixed energy environment of the e+ee^{+}e^{-} collider DAΦ\PhiNE, KLOE can measure the cross section of the process e+ee^{+}e^{-} \to hadrons as a function of the hadronic system energy using the radiative return. At energies below 1 GeV, e+eρπ+πe^{+}e^{-} \to \rho \to \pi^{+}\pi^{-} is the dominating hadronic process. We report here on the status of the analysis for the e^{+}e^{-} \to \ppg channel, which allows to obtain a preliminary measurement of the pion form factor using an integrated luminosity of 73pb1\sim73 pb^{-1}.Comment: Invited talk at the Seventh International Workshop on Tau Lepton Physics (TAU02-WE07), Santa Cruz, Ca, USA, Sept 2002, 9 pages, LaTeX, 9 eps figure
    corecore