780 research outputs found

    Cryogenic issues for LEP in 2000

    Get PDF

    Specification of Four New Large 4.5 K Helium Refrigerators for the LHC

    Get PDF
    The cooling capacity for the superconducting magnets in the Large Hadron Collider (LHC) at the European Laboratory for Particle Physics, CERN will be provided by eight helium refrigerators serving the eight 3.3 km long machine sectors. Of these eight refrigerators, four are already existing and are currently used for the Large Electron Positron Collider (LEP) project. These existing refrigerators have to be modified to serve the requirements for the LHC. Four new refrigerators providing cooling capacity down to 4.5 K will be added. All eight 4.5 K refrigerators will be completed by 1.8 K cooling stages. This presentation recalls the cryogenic architecture of the LHC, the constraints in process design resulting from it and from the desired capacity for steady state and transient operation. It then describes how these requirements were expressed in the technical specification for the four new 4.5 K refrigerators to be delivered between the years 2000 and 2002

    Economics of Large Helium Cryogenic Systems: experience from Recent Projects at CERN

    Get PDF
    Large projects based on applied superconductivity, such as particle accelerators, tokamaks or SMES, require powerful and complex helium cryogenic systems, the cost of which represents a significant, if not dominant fraction of the total capital and operational expenditure. It is therefore important to establish guidelines and scaling laws for costing such systems, based on synthetic estimators of their size and performance. Although such data has already been published for many years, the experience recently gathered at CERN with the LEP and LHC projects, which have de facto turned the laboratory into a major world cryogenic center, can be exploited to update this information and broaden the range of application of the scaling laws. We report on the economics of 4.5 K and 1.8 K refrigeration, cryogen distribution and storage systems, and indicate paths towards their cost-to-performance optimisation

    Specification of Eight 2400 W @ 1.8 K Refrigeration Units for the LHC

    Get PDF
    The cooling capacity below 2 K for the superconducting magnets in the Large Hadron Collider (LHC), at CERN, will be provided by eight refrigeration units at 1.8 K, each of them coupled to a 4.5 K refrigerator. Taking into account the cryogenic architecture of the LHC and corresponding process design constraints, a reference solution based on a combination of cold centrifugal and warm volumetric compressors was established in 1997. The process and technical requirements expressed in the specification issued in 1998 and the procurement scenario based on pre-series acceptance prior to final series delivery between 2002 and 2004 are presented in this paper

    A new airborne Polar Nephelometer for the measurement of optical and microphysical cloud properties. Part II: Preliminary tests

    Get PDF
    International audienceA new optical sensor, the airborne Polar Nephelometer, has been tested in an open wind tunnel. The wind tunnel was operated in cloudy conditions including either cloud water droplets or ice crystals, or a mixture of these particles. The sensor is designed to measure the optical and microphysical parameters of cloud particles sized from a few micrometers to about 500 µm diameter. Basically, the probe measures the scattering phase function of an ensemble of cloud particles which intersect a collimated laser beam near the focal point of a paraboloidal mirror. From the measured scattering phase function the retrieval of the droplet-size spectra and subsequent derived quantities such as liquid water content and size parameters can be calculated using an inversion method. The particle phase discrimination (water droplets/ice particles) can be derived from the shape of the scattering phase function and the sensitivity of the probe allows the detection of small ice crystals (typically of 5 µm diameter). The paper describes the preliminary results obtained by the prototype version of the Polar Nephelometer in various cloudy conditions. These results are compared with direct microphysical measurements obtained by usual PMS probes also mounted in the wind tunnel. Complementary results obtained in a cold chamber are presented in order to illustrate the reliability of the Polar Nephelometer in the presence of small ice crystals

    PIRATE project: point-of-care, informatics-based randomised controlled trial for decreasing overuse of antibiotic therapy in Gram-negative bacteraemia.

    Get PDF
    Antibiotic overuse drives antibiotic resistance. The optimal duration of antibiotic therapy for Gram-negative bacteraemia (GNB), a common community and hospital-associated infection, remains unknown and unstudied via randomised controlled trials (RCTs). This investigator-initiated, multicentre, non-inferiority, informatics-based point-of-care RCT will randomly assign adult hospitalised patients receiving microbiologically efficacious antibiotic(s) for GNB to (1) 14 days of antibiotic therapy, (2) 7 days of therapy or (3) an individualised duration determined by clinical response and 75% reduction in peak C reactive protein (CRP) values. The randomisation will occur in equal proportions (1:1:1) on day 5 (±1) of efficacious antibiotic therapy as determined by antibiogram; patients, their physicians and study investigators will be blind to treatment duration allocation until the day of antibiotic discontinuation. Immunosuppressed patients and those with GNB due to complicated infections (endocarditis, osteomyelitis, etc) and/or non-fermenting bacilli ( <i>Acinetobacter</i> spp, <i>Burkholderia</i> spp, <i>Pseudomonas</i> spp) <i>Brucella</i> spp, <i>Fusobacterium</i> spp or polymicrobial growth with Gram-positive organisms will be ineligible. The primary outcome is incidence of clinical failure at day 30; secondary outcomes include clinical failure, all-cause mortality and incidence of <i>Clostridiumdifficile</i> infection in the 90-day study period. An interim safety analysis will be performed after the first 150 patients have been followed for ≤30 days. Given a chosen margin of 10%, the required sample size to determine non-inferiority is roughly 500 patients. Analyses will be performed on both intention-to-treat and per-protocol populations. Ethics approval was obtained from the cantonal ethics committees of all three participating sites. Results of the main trial and each of the secondary endpoints will be submitted for publication in a peer-reviewed journal. This trial is registered at www.clinicaltrials.gov (NCT03101072; pre-results)

    Health-care-associated infections in neonates, children, and adolescents: an analysis of paediatric data from the European Centre for Disease Prevention and Control point-prevalence survey.

    Get PDF
    BACKGROUND: In 2011-12, the European Centre for Disease Prevention and Control (ECDC) held the first Europe-wide point-prevalence survey of health-care-associated infections in acute care hospitals. We analysed paediatric data from this survey, aiming to calculate the prevalence and type of health-care-associated infections in children and adolescents in Europe and to determine risk factors for infection in this population. METHODS: Point-prevalence surveys took place from May, 2011, to November, 2012, in 1149 hospitals in EU Member States, Iceland, Norway, and Croatia. Patients present on the ward at 0800 h on the day of the survey and who were not discharged at the time of the survey were included. Data were collected by locally trained health-care workers according to patient-based or unit-based protocols. We extracted data from the ECDC database for all paediatric patients (age 0-18 years). We report adjusted prevalence for health-care-associated infections by clustering at the hospital and country level. We also calculated risk factors for development of health-care-associated infections with use of a generalised linear mixed-effects model. FINDINGS: We analysed data for 17 273 children and adolescents from 29 countries. 770 health-care-associated infections were reported in 726 children and adolescents, corresponding to a prevalence of 4·2% (95% CI 3·7-4·8). Bloodstream infections were the most common type of infection (343 [45%] infections), followed by lower respiratory tract infections (171 [22%]), gastrointestinal infections (64 [8%]), eye, ear, nose, and throat infections (55 [7%]), urinary tract infections (37 [5%]), and surgical-site infections (34 [4%]). The prevalence of infections was highest in paediatric intensive care units (15·5%, 95% CI 11·6-20·3) and neonatal intensive care units (10·7%, 9·0-12·7). Independent risk factors for infection were age younger than 12 months, fatal disease (via ultimately and rapidly fatal McCabe scores), prolonged length of stay, and the use of invasive medical devices. 392 microorganisms were reported for 342 health-care-associated infections, with Enterobacteriaceae being the most frequently found (113 [15%]). INTERPRETATION: Infection prevention and control strategies in children should focus on prevention of bloodstream infections, particularly among neonates and infants. FUNDING: None

    Quasi-long range order in the random anisotropy Heisenberg model

    Full text link
    The large distance behaviors of the random field and random anisotropy Heisenberg models are studied with the functional renormalization group in 4ϵ4-\epsilon dimensions. The random anisotropy model is found to have a phase with the infinite correlation radius at low temperatures and weak disorder. The correlation function of the magnetization obeys a power law <m(r1)m(r2)>r1r20.62ϵ<{\bf m}({\bf r}_1) {\bf m}({\bf r}_2)>\sim| {\bf r}_1-{\bf r}_2|^{-0.62\epsilon}. The magnetic susceptibility diverges at low fields as χH1+0.15ϵ\chi\sim H^{-1+0.15\epsilon}. In the random field model the correlation radius is found to be finite at the arbitrarily weak disorder.Comment: 4 pages, REVTe

    Airborne observations of the Eyjafjalla volcano ash cloud over Europe during air space closure in April and May 2010

    Get PDF
    © Author(s) 2011. This work is distributed under the Creative Commons Attribution 3.0 LicenseAirborne lidar and in-situ measurements of aerosols and trace gases were performed in volcanic ash plumes over Europe between Southern Germany and Iceland with the Falcon aircraft during the eruption period of the Eyjafjalla1 volcano between 19 April and 18 May 2010. Flight planning and measurement analyses were supported by a refined Meteosat ash product and trajectory model analysis. The volcanic ash plume was observed with lidar directly over the volcano and up to a distance of 2700 km downwind, and up to 120 h plume ages. Aged ash layers were between a few 100 m to 3 km deep, occurred between 1 and 7 km altitude, and were typically 100 to 300 km wide. Particles collected by impactors had diameters up to 20 μm diameter, with size and age dependent composition. Ash mass concentrations were derived from optical particle spectrometers for a particle density of 2.6 g cm-3 and various values of the refractive index (RI, real part: 1.59; 3 values for the imaginary part: 0, 0.004 and 0.008). The mass concentrations, effective diameters and related optical properties were compared with ground-based lidar observations. Theoretical considerations of particle sedimentation constrain the particle diameters to those obtained for the lower RI values. The ash mass concentration results have an uncertainty of a factor of two. The maximum ash mass concentration encountered during the 17 flights with 34 ash plume penetrations was below 1 mg m-3. The Falcon flew in ash clouds up to about 0.8 mg m-3 for a few minutes and in an ash cloud with approximately 0.2 mg -3 mean-concentration for about one hour without engine damage. The ash plumes were rather dry and correlated with considerable CO and SO2 increases and O3 decreases. To first order, ash concentration and SO2 mixing ratio in the plumes decreased by a factor of two within less than a day. In fresh plumes, the SO2 and CO concentration increases were correlated with the ash mass concentration. The ash plumes were often visible slantwise as faint dark layers, even for concentrations below 0.1 mg m-3. The large abundance of volatile Aitken mode particles suggests previous nucleation of sulfuric acid droplets. The effective diameters range between 0.2 and 3 μm with considerable surface and volume contributions from the Aitken and coarse mode aerosol, respectively. The distal ash mass flux on 2 May was of the order of 500 (240-1600) kgs -1. The volcano induced about 10 (2.5-50) Tg of distal ash mass and about 3 (0.6-23) Tg of SO2 during the whole eruption period. The results of the Falcon flights were used to support the responsible agencies in their decisions concerning air traffic in the presence of volcanic ash.Peer reviewe
    corecore