1,545 research outputs found

    Ultracold Atoms as a Target: Absolute Scattering Cross-Section Measurements

    Full text link
    We report on a new experimental platform for the measurement of absolute scattering cross-sections. The target atoms are trapped in an optical dipole trap and are exposed to an incident particle beam. The exponential decay of the atom number directly yields the absolute total scattering cross-section. The technique can be applied to any atomic or molecular species that can be prepared in an optical dipole trap and provides a large variety of possible scattering scenarios

    Adiabatic loading of a Bose-Einstein condensate in a 3D optical lattice

    Full text link
    We experimentally investigate the adiabatic loading of a Bose-Einstein condensate into an optical lattice potential. The generation of excitations during the ramp is detected by a corresponding decrease in the visibility of the interference pattern observed after free expansion of the cloud. We focus on the superfluid regime, where we show that the limiting time scale is related to the redistribution of atoms across the lattice by single-particle tunneling

    Probing the hydrogen melting line at high pressures by dynamic compression

    Get PDF
    We investigate the capabilities of dynamic compression by intense heavy ion beams to yield information about the high pressure phases of hydrogen. Employing ab initio simulations and experimental data, a new wide range equation of state for hydrogen is constructed. The results show that the melting line up to its maximum as well as the transition from molecular fluids to fully ionized plasmas can be tested with the beam parameters soon to be available. We demonstrate that x-ray scattering can distinguish between phases and dissociation states

    All-optical formation of a Bose-Einstein condensate for applications in scanning electron microscopy

    Full text link
    We report on the production of a F=1 spinor condensate of 87Rb atoms in a single beam optical dipole trap formed by a focused CO2 laser. The condensate is produced 13mm below the tip of a scanning electron microscope employing standard all-optical techniques. The condensate fraction contains up to 100,000 atoms and we achieve a duty cycle of less than 10s.Comment: 5 pages, 4 figure

    Study of Light Backgrounds from Relativistic Electrons in Air Light-Guides

    Full text link
    The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (M{\o}ller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the M{\o}ller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.Comment: Published in NIM.

    Profound Morphological Changes in the Erythrocytes and Fibrin Networks of Patients with Hemochromatosis or with Hyperferritinemia, and Their Normalization by Iron Chelators and Other Agents

    Get PDF
    It is well-known that individuals with increased iron levels are more prone to thrombotic diseases, mainly due to the presence of unliganded iron, and thereby the increased production of hydroxyl radicals. It is also known that erythrocytes (RBCs) may play an important role during thrombotic events. Therefore the purpose of the current study was to assess whether RBCs had an altered morphology in individuals with hereditary hemochromatosis (HH), as well as some who displayed hyperferritinemia (HF). Using scanning electron microscopy, we also assessed means by which the RBC and fibrin morphology might be normalized. An important objective was to test the hypothesis that the altered RBC morphology was due to the presence of excess unliganded iron by removing it through chelation. Very striking differences were observed, in that the erythrocytes from HH and HF individuals were distorted and had a much greater axial ratio compared to that accompanying the discoid appearance seen in the normal samples. The response to thrombin, and the appearance of a platelet-rich plasma smear, were also markedly different. These differences could largely be reversed by the iron chelator desferal and to some degree by the iron chelator clioquinol, or by the free radical trapping agents salicylate or selenite (that may themselves also be iron chelators). These findings are consistent with the view that the aberrant morphology of the HH and HF erythrocytes is caused, at least in part, by unliganded (‘free’) iron, whether derived directly via raised ferritin levels or otherwise, and that lowering it or affecting the consequences of its action may be of therapeutic benefit. The findings also bear on the question of the extent to which accepting blood donations from HH individuals may be desirable or otherwise

    A Current Mode Detector Array for Gamma-Ray Asymmetry Measurements

    Full text link
    We have built a CsI(Tl) gamma-ray detector array for the NPDGamma experiment to search for a small parity-violating directional asymmetry in the angular distribution of 2.2 MeV gamma-rays from the capture of polarized cold neutrons by protons with a sensitivity of several ppb. The weak pion-nucleon coupling constant can be determined from this asymmetry. The small size of the asymmetry requires a high cold neutron flux, control of systematic errors at the ppb level, and the use of current mode gamma-ray detection with vacuum photo diodes and low-noise solid-state preamplifiers. The average detector photoelectron yield was determined to be 1300 photoelectrons per MeV. The RMS width seen in the measurement is therefore dominated by the fluctuations in the number of gamma rays absorbed in the detector (counting statistics) rather than the intrinsic detector noise. The detectors were tested for noise performance, sensitivity to magnetic fields, pedestal stability and cosmic background. False asymmetries due to gain changes and electronic pickup in the detector system were measured to be consistent with zero to an accuracy of 10910^{-9} in a few hours. We report on the design, operating criteria, and the results of measurements performed to test the detector array.Comment: 33 pages, 20 figures, 2 table

    Cooling toolbox for atoms in optical lattices

    Full text link
    We propose and analyze several schemes for cooling bosonic and fermionic atoms in an optical lattice potential close to the ground state of the no-tunnelling regime. Some of the protocols rely on the concept of algorithmic cooling, which combines occupation number filtering with ideas from ensemble quantum computation. We also design algorithms that create an ensemble of defect-free quantum registers. We study the efficiency of our protocols for realistic temperatures and in the presence of a harmonic confinement. We also propose an incoherent physical implementation of filtering which can be operated in a continuous way.Comment: 14 pages, 13 figure

    Precision measurement of spin-dependent interaction strengths for spin-1 and spin-2 87Rb atoms

    Full text link
    We report on precision measurements of spin-dependent interaction-strengths in the 87Rb spin-1 and spin-2 hyperfine ground states. Our method is based on the recent observation of coherence in the collisionally driven spin-dynamics of ultracold atom pairs trapped in optical lattices. Analysis of the Rabi-type oscillations between two spin states of an atom pair allows a direct determination of the coupling parameters in the interaction hamiltonian. We deduce differences in scattering lengths from our data that can directly be compared to theoretical predictions in order to test interatomic potentials. Our measurements agree with the predictions within 20%. The knowledge of these coupling parameters allows one to determine the nature of the magnetic ground state. Our data imply a ferromagnetic ground state for 87Rb in the f=1 manifold, in agreement with earlier experiments performed without the optical lattice. For 87Rb in the f=2 manifold the data points towards an antiferromagnetic ground state, however our error bars do not exclude a possible cyclic phase.Comment: 11 pages, 5 figure

    New measurement of the scattering cross section of slow neutrons on liquid parahydrogen from neutron transmission

    Get PDF
    Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many body physics. Unfortunately, the pair correlation function g(r)g(r) inferred from neutron scattering measurements of the differential cross section dσdΩd\sigma \over d\Omega from different measurements reported in the literature are inconsistent. We have measured the energy dependence of the total cross section and the scattering cross section for slow neutrons with energies between 0.43~meV and 16.1~meV on liquid hydrogen at 15.6~K (which is dominated by the parahydrogen component) using neutron transmission measurements on the hydrogen target of the NPDGamma collaboration at the Spallation Neutron Source at Oak Ridge National Laboratory. The relationship between the neutron transmission measurement we perform and the total cross section is unambiguous, and the energy range accesses length scales where the pair correlation function is rapidly varying. At 1~meV our measurement is a factor of 3 below the data from previous work. We present evidence that these previous measurements of the hydrogen cross section, which assumed that the equilibrium value for the ratio of orthohydrogen and parahydrogen has been reached in the target liquid, were in fact contaminated with an extra non-equilibrium component of orthohydrogen. Liquid parahydrogen is also a widely-used neutron moderator medium, and an accurate knowledge of its slow neutron cross section is essential for the design and optimization of intense slow neutron sources. We describe our measurements and compare them with previous work.Comment: Edited for submission to Physical Review
    corecore