3,311 research outputs found

    A microangiographic study of the effect of hyperthermia on the rabbit bladder

    Get PDF
    A model was used to study the effect of hyperthermia on a normal tissue. The model selected was the rabbit bladder and the end point measured was the changes in the micro-vasculature of the bladder wall. It was already demonstrated clinically that hot water bladder infusions produce regression in bladder tumors

    SPEDEN: Reconstructing single particles from their diffraction patterns

    Full text link
    Speden is a computer program that reconstructs the electron density of single particles from their x-ray diffraction patterns, using a single-particle adaptation of the Holographic Method in crystallography. (Szoke, A., Szoke, H., and Somoza, J.R., 1997. Acta Cryst. A53, 291-313.) The method, like its parent, is unique that it does not rely on ``back'' transformation from the diffraction pattern into real space and on interpolation within measured data. It is designed to deal successfully with sparse, irregular, incomplete and noisy data. It is also designed to use prior information for ensuring sensible results and for reliable convergence. This article describes the theoretical basis for the reconstruction algorithm, its implementation and quantitative results of tests on synthetic and experimentally obtained data. The program could be used for determining the structure of radiation tolerant samples and, eventually, of large biological molecular structures without the need for crystallization.Comment: 12 pages, 10 figure

    A representative sample of Be stars III: H band spectroscopy

    Get PDF
    We present H band (1.53 - 1.69 micron) spectra of 57 isolated Be stars of spectral types O9-B9 and luminosity classes III,IV & V. The HI Brackett (n-4) series is seen in emission from Br 11-18, and FeII emission is also apparent for a subset of those stars with HI emission. No emission from species with a higher excitation temperature, such as He II or CIII is seen, and no forbidden line emission is present. A subset of 12 stars show no evidence for emission from any species; these stars appear indistinguishable from normal B stars of a comparable spectral type. In general the line ratios constructed from the transitions in the range Br 11-18 do not fit case B recombination theory particularly well. Strong correlations between the line ratios with Br-gamma and spectral type are found. These results most likely represent systematic variations in the temperature and ionization of the circumstellar disc with spectral type. Weak correlations between the line widths and projected rotational velocity of the stars are observed; however no systematic trend for increasing line width through the Brackett series is observed.Comment: accepted for publication in A&A (this version correctly formatted

    Use of extended and prepared reference objects in experimental Fourier transform X-ray holography

    Full text link
    The use of one or more gold nanoballs as reference objects for Fourier Transform holography (FTH) is analysed using experimental soft X-ray diffraction from objects consisting of separated clusters of these balls. The holograms are deconvoluted against ball reference objects to invert to images, in combination with a Wiener filter to control noise. A resolution of ~30nm, smaller than one ball, is obtained even if a large cluster of balls is used as the reference, giving the best resolution yet obtained by X-ray FTH. Methods of dealing with missing data due to a beamstop are discussed. Practical prepared objects which satisfy the FTH condition are suggested, and methods of forming them described.Comment: 7 pages, 2 figures, submitted to Applied Physics Letter

    Phasing diffuse scattering. Application of the SIR2002 algorithm to the non-crystallographic phase problem

    Full text link
    A new phasing algorithm has been used to determine the phases of diffuse elastic X-ray scattering from a non-periodic array of gold balls of 50 nm diameter. Two-dimensional real-space images, showing the charge-density distribution of the balls, have been reconstructed at 50 nm resolution from transmission diffraction patterns recorded at 550 eV energy. The reconstructed image fits well with scanning electron microscope (SEM) image of the same sample. The algorithm, which uses only the density modification portion of the SIR2002 program, is compared with the results obtained via the Gerchberg-Saxton-Fienup HIO algorithm. In this way the relationship between density modification in crystallography and the HiO algorithm used in signal and image processing is elucidated.Comment: 7 pages, 12 figure

    Mesoscale observations of Joule heating near an auroral arc and ion-neutral collision frequency in the polar cap E region

    Get PDF
    We report on the first mesoscale combined ionospheric and thermospheric observations, partly in the vicinity of an auroral arc, from Svalbard in the polar cap on 2 February 2010. The EISCAT Svalbard radar employed a novel scanning mode in order to obtain F and E region ion flows over an annular region centered on the radar. Simultaneously, a colocated Scanning Doppler Imager observed the E region neutral winds and temperatures around 110 km altitude using the 557.7 nm auroral optical emission. Combining the ion and neutral data permits the E region Joule heating to be estimated with an azimuthal spatial resolution of ∼64 km at a radius of ∼163 km from the radar. The spatial distribution of Joule heating shows significant mesoscale variation. The ion-neutral collision frequency is measured in the E region by combining all the data over the entire field of view with only weak aurora present. The estimated ion-neutral collision frequency at ∼113 km altitude is in good agreement with the MSIS atmospheric model

    Progress in Three-Dimensional Coherent X-Ray Diffraction Imaging

    Get PDF
    The Fourier inversion of phased coherent diffraction patterns offers images without the resolution and depth-of-focus limitations of lens-based tomographic systems. We report on our recent experimental images inverted using recent developments in phase retrieval algorithms, and summarize efforts that led to these accomplishments. These include ab-initio reconstruction of a two-dimensional test pattern, infinite depth of focus image of a thick object, and its high-resolution (~10 nm resolution) three-dimensional image. Developments on the structural imaging of low density aerogel samples are discussed.Comment: 5 pages, X-Ray Microscopy 2005, Himeji, Japa

    “When it goes back to my normal I suppose”: a qualitative study using online focus groups to explore perceptions of ‘control’ amongst people with eczema and parents of children with eczema in the UK

    Get PDF
    Objective: To inform the development of a core outcome set for eczema by engaging with people with eczema and parents of children with eczema to understand their experiences and understanding of the concept “eczema control”. Design: 37 participants took part in a total of 6 semi-structured online focus groups held in a typed chatroom with 5-7 participants per group. Three groups involved adults with eczema and three groups involved parents of children with eczema. Framework analysis was used for data analysis. Setting: A community-based sample was recruited from across the UK via social media and email. Participants: 19 adults aged 17-61 (15/19 female, 16/19 white) and 18 parents of children with eczema aged 9 months-17 years (9/18 female, 18/19 white). Results: Four main themes were identified. 1) “Commonalities and differences in the experiences of control”: a reduction in symptoms such as itch and sleep loss characterised eczema control, but what level was acceptable differed across participants. 2) “Eczema control goes beyond the skin”: psychological factors, social factors, the constant scratching and the impact on everyday activities are a variety of ways an individual can be impacted. 3) “Stepping up and down of treatment”: participants’ stepped-up treatment in response to loss of control, but several factors complicated this behaviour. Control needed to be maintained after stepped-up treatment ended to be acceptable. 4) “How to measure control”: self-report was generally preferred to allow frequent measurements and to capture unobservable features. Although most thought their eczema needed to be measured frequently, many also felt that this was not always realistic or desirable. Conclusions: Eczema “control” is a complex experience for people with eczema and parents of children with the condition. These experiences could have important implications on how long-term control should be measured in eczema clinical trials and clinical practice

    Three-dimensional coherent X-ray diffraction imaging of a ceramic nanofoam: determination of structural deformation mechanisms

    Full text link
    Ultra-low density polymers, metals, and ceramic nanofoams are valued for their high strength-to-weight ratio, high surface area and insulating properties ascribed to their structural geometry. We obtain the labrynthine internal structure of a tantalum oxide nanofoam by X-ray diffractive imaging. Finite element analysis from the structure reveals mechanical properties consistent with bulk samples and with a diffusion limited cluster aggregation model, while excess mass on the nodes discounts the dangling fragments hypothesis of percolation theory.Comment: 8 pages, 5 figures, 30 reference

    Photoelectron diffraction: from phenomenological demonstration to practical tool

    Get PDF
    The potential of photoelectron diffraction—exploiting the coherent interference of directly-emitted and elastically scattered components of the photoelectron wavefield emitted from a core level of a surface atom to obtain structural information—was first appreciated in the 1970s. The first demonstrations of the effect were published towards the end of that decade, but the method has now entered the mainstream armoury of surface structure determination. This short review has two objectives: First, to outline the way that the idea emerged and the way this evolved in my own collaboration with Neville Smith and his colleagues at Bell Labs in the early years: Second, to provide some insight into the current state-of-the art in application of (scanned-energy mode) photoelectron diffraction to address two key issue in quantitative surface structure determination, namely, complexity and precision. In this regard a particularly powerful aspect of photoelectron diffraction is its elemental and chemical-state specificity
    corecore