1,020 research outputs found

    Studies of the marine crustal magnetization at intermediate wavelengths

    Get PDF
    The data can be filtered at intermediate wavelengths to provde a data set which complements the satellite fields of MAGSAT, TSS and GRM. The filtered marine data set provides a high resolution data set which is closer to the source bodies than satellite survey data. However, the GRM and TSS could provide the necessary resolution to match the filtered sea surface field. The added resolution determines the nature of crustal magnetizations which give rise to the intermediate wavelength field. It is found that remanent magnetization is an important component over the oceans. Crustal deformation and plate motions result in magnetization vectors which differ significantly from the present day field directions. Induced magnetization or GRM are important components over the oceanic plateaus and spreading centers

    Mendelian randomization with a binary exposure variable: interpretation and presentation of causal estimates

    Get PDF
    Mendelian randomization uses genetic variants to make causal inferences about a modifiable exposure. Subject to a genetic variant satisfying the instrumental variable assumptions, an association between the variant and outcome implies a causal effect of the exposure on the outcome. Complications arise with a binary exposure that is a dichotomization of a continuous risk factor (for example, hypertension is a dichotomization of blood pressure). This can lead to violation of the exclusion restriction assumption: the genetic variant can influence the outcome via the continuous risk factor even if the binary exposure does not change. Provided the instrumental variable assumptions are satisfied for the underlying continuous risk factor, causal inferences for the binary exposure are valid for the continuous risk factor. Causal estimates for the binary exposure assume the causal effect is a stepwise function at the point of dichotomization. Even then, estimation requires further parametric assu

    The effects of childbirth on the pelvic-floor

    Get PDF
    Basically, vaginal delivery is associated with the risk of pelvic floor damage. The pelvic floor sequelae of childbirth includes anal incontinence, urinary incontinence and pelvic organ prolapse. Pathophysiology, incidence and risk factors for the development of the respective problems are reviewed. Where possible, recommendations for reducing the risk of pelvic floor damage are given

    Low-Resolution Imaging Spectrometer for the Keck Telescope

    Get PDF
    The Low Resolution Imaging Spectrometer is designed for use at the Cassegrain focus of the Keck 10-m telescope. It provides the capability of acquiring low resolution (R equals 1000 to 5000) digital spectra, as well as 6 X 8 arc-minute moderately high spatial resolution (4.65 pixels/arc-second) direct images. Spectroscopy can be carried out with single slits which are 3 arc-minutes long. In addition punched multi-slits can also be employed which allow for the acquisition of at least forty spectra simultaneously. Since the instrument is designed to be as efficient as possible, it is a double spectrograph, with a dichroic splitting the blue and red light into separate optical paths after the collimator. Only the red side has been constructed thus far. With a 2048 by 2048 thinned Tektronix CCD as the detector the total efficiency of the red side at the peak of the grating blaze is predicted to be nearly 40%. Results of the commissioning observing runs will be described

    Documenting the Anthropogenic Impact on Ballston Lake New York from a short core using stable isotopes of carbon and nitrogen and trace metals

    Get PDF
    Ballston Lake occupies a portion of an avulsed channel of the Mohawk River between Schenectady and Saratoga Springs, New York. The lake is about 5 km long, generally less than 200m wide, ~8-15m deep, dimictic, with a catchment basin area of ~22km2. Long cores (\u3e8 m) indicate that the lake formed ~13,000 cal yr BP. This study was undertaken to document recent environmental change recorded in the upper portion of sediment in Ballston Lake. Three sediment cores ~40 cm long were acquired from ~8 m water depth at the north end of Ballston Lake (42°57.101’N, 73°51.066’W), and were analyzed for exchangeable metals, magnetic susceptibility, total organic carbon (TOC), total inorganic carbon (TIC), organic carbon to nitrogen ratios (C/N), and stable isotopes of carbon and nitrogen. An age model of the cores was established by correlating a prominent increase in Pb (1882 AD) and the Pb maximum (1970) based on 210Pb dating of cores from nearby lakes (Round Pond and Long Pond). Cu and Zn reflect similar increasing trends at this time, and these increases are likely attributed to industrialization and the burning of fossil fuels throughout the 20th century. 13C values become more negative through time, declining from -29 to -30.5‰, suggesting the organic carbon is more aquatically derived. Percent TOC increases towards the surface of the core demonstrating increased productivity that is unrelated to nitrogen input, as %N and 15N values are relatively constant. Though the data suggests that development around Ballston Lake has had only a minor impact on productivity and pollution, there are apparent changes that occurred in the lake between AD ~1970 and 1981. The increase in TIC and decrease in TOC, 13C values, and grey scale values suggest there was an increase in clastic sediment input into the lake and reduction in terrestrial organic matter input. This event could be caused by the severe drought in New England that occurred in the 1960s, killing vegetation and weakening the erodible surfaces. Ballston Lake should be monitored for anthropogenic pollution in the future, though there has been little anthropogenic impact at this point in time

    The Keck Low-Resolution Imaging Spectrometer

    Get PDF
    The Low Resolution Imaging Spectrometer (LRIS) for the Cassegrain focus of the Keck 10-m telescope on Mauna Kea is described. It has an imaging mode so it can also be used for taking direct images. The field of view in both spectrographic and imaging modes is 6 by 7.8 arcmin. It can be used with both conventional slits and custom-punched slit masks. The optical quality of the spectrograph is good enough to take full advantage of the excellent imaging properties of the telescope itself. The detector is a cooled back-illuminated Tektronics Inc. 2048 X 2048 CCD which gives a sampling rate of 4.685 pixels per arcsec. In the spectrographic mode the spectrograph has a maximum efficiency at the peak of the grating blaze of 32%-34% for the two lowest resolution gratings and 28% for the 1200 g mm^(-1) grating. This efficiency includes the detector but not the telescope or the atmosphere

    Active Mg Estimation Using Thermal Analysis: A Rapid Method to Control Nodularity in Ductile Cast Iron Production

    Get PDF
    Appropriate nodularity in ductile iron castings is strongly associated with the presence of high enough not combined Mg dissolved in the melt to cast. However, the residual Mg which is commonly measured for production control accounts for both dissolved Mg and Mg combined as oxides and sulfides. To account for the uncertainties associated with such a control, it is quite usual to over treat the melt with the risk of porosity appearance. A new methodology based on thermal analysis has been developed in the present work so as to estimate the amount of free Mg dissolved in the melt ready for pouring. A combination of Te mixture and a new “reactive mixture” composed of sulfur plus a commercial inoculant has been prepared for this purpose. This reactive mixture is able to transform the magnesium remaining dissolved in the melt to combined forms of this element. Experiments performed both during start of production (when Mg overtreatment is usual) and during normal mass production indicate that important variations of free Mg occur without relevant changes in residual Mg content as determined by spectrometry. The method developed in the present work has shown to be highly effective to detect those melt batches where active Mg content is not high enough for guaranteeing a correct nodularity of castings. Selection of proper active Mg thresholds and a correct inoculation process are critical to avoid “false”-negative results when using this new method
    corecore