1,303 research outputs found
Plans for the LIGO–TAMA joint search for gravitational wave bursts
We describe the plans for a joint search for unmodelled gravitational wave bursts being carried out by the LIGO and TAMA Collaborations using data collected during February–April 2003. We take a conservative approach to detection, requiring candidate gravitational wave bursts to be seen in coincidence by all four interferometers. We focus on some of the complications of performing this coincidence analysis, in particular the effects of the different alignments and noise spectra of the interferometers
Precise calibration of LIGO test mass actuators using photon radiation pressure
Precise calibration of kilometer-scale interferometric gravitational wave
detectors is crucial for source localization and waveform reconstruction. A
technique that uses the radiation pressure of a power-modulated auxiliary laser
to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a
so-called photon calibrator, has been demonstrated previously and has recently
been implemented on the LIGO detectors. In this article, we discuss the
inherent precision and accuracy of the LIGO photon calibrators and several
improvements that have been developed to reduce the estimated voice coil
actuator calibration uncertainties to less than 2 percent (1-sigma). These
improvements include accounting for rotation-induced apparent length variations
caused by interferometer and photon calibrator beam centering offsets, absolute
laser power measurement using temperature-controlled InGaAs photodetectors
mounted on integrating spheres and calibrated by NIST, minimizing errors
induced by localized elastic deformation of the mirror surface by using a
two-beam configuration with the photon calibrator beams symmetrically displaced
about the center of the optic, and simultaneously actuating the test mass with
voice coil actuators and the photon calibrator to minimize fluctuations caused
by the changing interferometer response. The photon calibrator is able to
operate in the most sensitive interferometer configuration, and is expected to
become a primary calibration method for future gravitational wave searches.Comment: 13 pages, 6 figures, accepted by Classical and Quantum Gravit
A Population of Short-Period Variable Quasars from PTF as Supermassive Black Hole Binary Candidates
Supermassive black hole binaries (SMBHBs) at sub-parsec separations should be
common in galactic nuclei, as a result of frequent galaxy mergers.
Hydrodynamical simulations of circumbinary discs predict strong periodic
modulation of the mass accretion rate on time-scales comparable to the orbital
period of the binary. As a result, SMBHBs may be recognized by the periodic
modulation of their brightness. We conducted a statistical search for periodic
variability in a sample of 35,383 spectroscopically confirmed quasars in the
photometric database of the Palomar Transient Factory (PTF). We analysed
Lomb-Scargle periodograms and assessed the significance of our findings by
modeling each individual quasar's variability as a damped random walk (DRW). We
identified 50 quasars with significant periodicity beyond the DRW model,
typically with short periods of a few hundred days. We find 33 of these to
remain significant after a re-analysis of their periodograms including
additional optical data from the intermediate-PTF and the Catalina Real-Time
Transient Survey (CRTS). Assuming that the observed periods correspond to the
redshifted orbital periods of SMBHBs, we conclude that our findings are
consistent with a population of unequal-mass SMBHBs, with a typical mass ratio
as low as q = M2/M1 ~ 0.01.Comment: MNRAS (accepted), new section 4.
Precise calibration of LIGO test mass actuators using photon radiation pressure
Precise calibration of kilometer-scale interferometric gravitational wave
detectors is crucial for source localization and waveform reconstruction. A
technique that uses the radiation pressure of a power-modulated auxiliary laser
to induce calibrated displacements of one of the ~10 kg arm cavity mirrors, a
so-called photon calibrator, has been demonstrated previously and has recently
been implemented on the LIGO detectors. In this article, we discuss the
inherent precision and accuracy of the LIGO photon calibrators and several
improvements that have been developed to reduce the estimated voice coil
actuator calibration uncertainties to less than 2 percent (1-sigma). These
improvements include accounting for rotation-induced apparent length variations
caused by interferometer and photon calibrator beam centering offsets, absolute
laser power measurement using temperature-controlled InGaAs photodetectors
mounted on integrating spheres and calibrated by NIST, minimizing errors
induced by localized elastic deformation of the mirror surface by using a
two-beam configuration with the photon calibrator beams symmetrically displaced
about the center of the optic, and simultaneously actuating the test mass with
voice coil actuators and the photon calibrator to minimize fluctuations caused
by the changing interferometer response. The photon calibrator is able to
operate in the most sensitive interferometer configuration, and is expected to
become a primary calibration method for future gravitational wave searches.Comment: 13 pages, 6 figures, accepted by Classical and Quantum Gravit
Control and automatic alignment of the output mode cleaner of GEO 600
The implementation of a mode cleaner at the output port of the GEO 600 gravitational wave detector will be part of the upcoming transition from GEO 600 to GEO-HF. Part of the transition will be the move from a heterodyne readout to a DC readout scheme. DC readout performance will be limited by higher order optical modes and control sidebands present at the output port. For optimum performance of DC readout an output mode cleaner (OMC) will clean the output beam of these contributions. Inclusion of an OMC will introduce new noise sources whose magnitudes needed to be estimated and for which new control systems will be needed. In this article we set requirements on the performance of these control systems and investigate the simulated performance of different designs.Science and Technology Facilities Council (STFC)BMBFMax Planck Society (MPG)State of Lower Saxony in GermanyEuropean Gravitational Observatory (EGO)DFG/SFB/Transregio
A Compact Gas Cerenkov Detector with Novel Optics
We discuss the design and performance of a threshold Cerenkov counter for
identification of charged hadrons. The radiator is pressurized gas, which is
contained in thin-walled cylindrical modules. A mirror system of novel design
transports Cerenkov photons to photomultiplier tubes. This system is compact,
contains relatively little material, and has a large fraction of active volume.
A prototype of a module designed for the proposed CLEO III detector has been
studied using cosmic rays. Results from these studies show good agreement with
a detailed Monte Carlo simulation of the module and indicate that it should
achieve separation of pions and kaons at the 2.5-3.0sigma level in the momentum
range 0.8-2.8 GeV/c. We predict performance for specific physics analyses using
a GEANT-based simulation package.Comment: Submitted to NIM. 23 pages, 11 postscript figures. Postscript file is
also available at http://w4.lns.cornell.edu/public/CLNS/199
Commissioning of the tuned DC readout at GEO 600
Recent experimental results from GEO600 operating with a DC readout and a tuned signal recycling cavity are reported. Compared to the S5/Astrowatch setup, two major changes in the configuration have been implemented: the control readout to keep the interferometer on the dark fringe is changed from heterodyne to homodyne readout and the signal recycling cavity is shifted from a 550 Hz detuning to a 0 Hz detuning (also called tuned). As preliminary experiments showed, the tuned DC readout sensitivity is similar to the heterodyne one. To take advantage of the new DC readout detection scheme, an Output Mode Cleaner (OMC) has to be installed. The design, building and testing of the GEO OMC, which consists of a 4 mirrors monolithic ring cavity, will also be presented in this article.Science and Technology Facilities Council (STFC)BMBFMax Planck Society (MPG)State of Lower Saxony in GermanyEuropean Gravitational Observatory (EGO)DFG/SFB/Transregio
- …
