10 research outputs found

    Pelvic support hip reconstruction with internal devices : an alternative to Ilizarov hip reconstruction

    Get PDF
    Aim and objective: Ilizarov hip reconstruction (IHR) is a traditional method of salvaging chronic adolescent problem hips but faces practical problems from external fixators leading to reduced compliance. We present the same reconstruction utilising only internal devices with a modification in technique and aim to review early results. Materials and methods: We retrospectively evaluated eight patients between 2014 and 2017 with chronic painful hips treated by a two-stage reconstruction; stage 1 included femoral head resection and pelvic support osteotomy using double plating, while stage 2 comprised distal femoral osteotomy avoiding varus followed by insertion of retrograde magnetic nail for postoperative lengthening. Patients continued physiotherapy postoperatively while protecting from early weight-bearing. Results: At mean follow-up of 19 months (range 6–36), all osteotomies healed with bone healing index of 47 days/cm (range 30–72). Pain improved from 8.3 (range 7–9) to 2 (range 0–6), while limb length discrepancy got corrected from 4.3 cm (range 3–5) to 1.4 cm (range 0–2.5) at final follow-up. Trendelenburg sign was eliminated in three and delayed in five. No examples of infection or permanent knee stiffness were noted. One patient had plates breakage due to mechanical fall and one had 35 mm of lateral mechanical axis deviation requiring corrective osteotomy. Conclusion: Pelvic support hip reconstruction with exclusive internal devices is a technique in evolution with encouraging early results. It avoids common complications of external fixators and facilitates quick rehabilitation of joints. Refraining from distal varus can effectively eliminate Trendelenburg gait, albeit with some degree of lateral mechanical axis deviation. Unlike external fixation where there is a possibility of gradual correction, this staged procedure of internal fixation is technically demanding with a learning curve. Clinical significance: Pelvic support hip reconstruction performed by internal implants is a viable alternative to IHR with potential benefits

    A multichannel computer-driven system to raise aquatic embryos under selectable hypoxic conditions

    Get PDF
    Sanjeeva Metikala,1,2,* Herbert Neuhaus,1,* Thomas Hollemann1 1Department of Medical Molecular Biology, University Halle-Wittenberg, Institute for Physiological Chemistry, Halle, Germany; 2Division of Developmental Biology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH, USA *These authors contributed equally to this work Abstract: The formation of a functional cardiovascular system is an essential step in the early vertebrate embryo. Nevertheless, the effect of hypoxia on the developmental program of organisms was studied rarely. In particular, this holds true for vertebrate embryos that depend on a functional placenta for proper development and had not been studied in this respect due to the obvious limitation. We established a protocol to culture aquatic embryos, which enabled us to culture a high number of Xenopus embryos until tadpole stage under defined hypoxic conditions in four hypoxia chambers simultaneously, employing a computerized system. In general, our results show that hypoxia results in delayed development and, in particular, we could show that oxygen availability was most crucial during gastrulation and organogenesis (early tailbud) phases during embryonic development of Xenopus laevis. Keywords: Xenopus, hypoxia, vasculogenesis, culture conditions, er71, am

    Evaluation of the syndesmotic-only fixation for Weber-C ankle fractures with syndesmotic injury

    No full text
    Background: With the length of the fibula restored and the syndesmosis reduced anatomically, internal fixation using a plating device may not be necessary for supra-syndesmotic fibular fractures combined with diastasis of inferior tibio-fibular joint. A retrospective observational study was performed in patients who had this injury pattern treated with syndesmosis-only fixation. Materials and Methods: 12 patients who had Weber type-C injury pattern were treated with syndesmosis only fixation. The treatment plan was followed only if the fibular length could be restored and if the syndesmosis could be anatomically reduced. Through a percutaneous or mini-open reduction and clamp stabilization of the syndesmosis, all but one patient had a single tricortical screw fixation across the syndesmosis. Patients were kept non-weight-bearing for 6 weeks, followed by screw removal at an average of 8 weeks. Outcomes were assessed using an objective ankle scoring system (Olerud and Molander scale) and by radiographic assessment of the ankle mortise. Results: At a mean follow-up of 13 months, the functional outcome score was 75. Excellent to good outcomes were noted in 83% of the patients. Ankle mortise was reduced in all cases, and all but one fibular fracture united without loss of fixation. Six patients had more than one malleolar injury, needing either screw or anchor fixations. One patient had late diastasis after removal of the syndesmotic screw and underwent revision surgery with bone grafting of the fibula. This was probably due to early screw removal, before union of the fibular fracture had occurred. Conclusion: We recommend syndesmosis-only fixation as an effective treatment option for a combination of syndesmosis disruption and Weber type-C lateral malleolar fractures

    Authors’ reply

    Full text link
    corecore