27,569 research outputs found

    Development of mathematical models for processing S-193 radar altimeter data

    Get PDF
    There are no author-identified significant results in this report

    Acquisition of quick-look data from SL-2

    Get PDF
    There are no author-identified significant results in this report

    Engineering studies related to geodetic and oceanographic remote sensing using short pulse techniques

    Get PDF
    For the Skylab S-193 radar altimeter, data processing flow charts and identification of calibration requirements and problem areas for defined S-193 altimeter experiments are presented. An analysis and simulation of the relationship between one particular S-193 measurement and the parameter of interest for determining the sea surface scattering cross-section are considered. For the GEOS-C radar altimeter, results are presented for system analyses pertaining to signal-to-noise ratio, pulse compression threshold behavior, altimeter measurement variance characteristics, desirability of onboard averaging, tracker bandwidth considerations, and statistical character of the altimeter data in relation to harmonic analysis properties of the geodetic signal

    Altimeter waveform software design

    Get PDF
    Techniques are described for preprocessing raw return waveform data from the GEOS-3 radar altimeter. Topics discussed include: (1) general altimeter data preprocessing to be done at the GEOS-3 Data Processing Center to correct altimeter waveform data for temperature calibrations, to convert between engineering and final data units and to convert telemetered parameter quantities to more appropriate final data distribution values: (2) time "tagging" of altimeter return waveform data quantities to compensate for various delays, misalignments and calculational intervals; (3) data processing procedures for use in estimating spacecraft attitude from altimeter waveform sampling gates; and (4) feasibility of use of a ground-based reflector or transponder to obtain in-flight calibration information on GEOS-3 altimeter performance

    Development of mathematical models for processing altimeter data

    Get PDF
    There are no author-identified significant results in this report

    Microwave backscattering theory and active remote sensing of the ocean surface

    Get PDF
    The status is reviewed of electromagnetic scattering theory relative to the interpretation of microwave remote sensing data acquired from spaceborne platforms over the ocean surface. Particular emphasis is given to the assumptions which are either implicit or explicit in the theory. The multiple scale scattering theory developed during this investigation is extended to non-Gaussian surface statistics. It is shown that the important statistic for the case is the probability density function of the small scale heights conditioned on the large scale slopes; this dependence may explain the anisotropic scattering measurements recently obtained with the AAFE Radscat. It is noted that present surface measurements are inadequate to verify or reject the existing scattering theories. Surface measurements are recommended for qualifying sensor data from radar altimeters and scatterometers. Additional scattering investigations are suggested for imaging type radars employing synthetically generated apertures

    Comparison of human uterine cervical electrical impedance measurements derived using two tetrapolar probes of different sizes

    Get PDF
    BACKGROUND We sought to compare uterine cervical electrical impedance spectroscopy measurements employing two probes of different sizes, and to employ a finite element model to predict and compare the fraction of electrical current derived from subepithelial stromal tissue. METHODS Cervical impedance was measured in 12 subjects during early pregnancy using 2 different sizes of the probes on each subject. RESULTS Mean cervical resistivity was significantly higher (5.4 vs. 2.8 Ωm; p < 0.001) with the smaller probe in the frequency rage of 4–819 kHz. There was no difference in the short-term intra-observer variability between the two probes. The cervical impedance measurements derived in vivo followed the pattern predicted by the finite element model. CONCLUSION Inter-electrode distance on the probes for measuring cervical impedance influences the tissue resistivity values obtained. Determining the appropriate probe size is necessary when conducting clinical studies of resistivity of the cervix and other human tissues

    Thinking strategically about assessment

    Get PDF
    Drawing upon the literature on strategy formulation in organisations, this paper argues for a focus on strategy as process. It relates this to the need to think strategically about assessment, a need engendered by resource pressures, developments in learning and the demands of external stakeholders. It is argued that in practice assessment strategies are often formed at the level of practice, but that this produces contradiction and confusion at higher levels. Such tensions cannot be managed away, but they can be reflected on and mitigated. The paper suggests a framework for the construction of assessment strategies at different levels of an institution. However, the main conclusion is that the process of constructing such strategies should be an opportunity for learning and reflection, rather than one of compliance

    Quantitative sensory testing in children with sickle cell disease: additional insights and future possibilities.

    Get PDF
    Quantitative sensory testing (QST) is used in a variety of pain disorders to characterize pain and predict prognosis and response to specific therapies. In this study, we aimed to confirm results in the literature documenting altered QST thresholds in sickle cell disease (SCD) and assess the test-retest reliability of results over time. Fifty-seven SCD and 60 control subjects aged 8-20 years underwent heat and cold detection and pain threshold testing using a Medoc TSAII. Participants were tested at baseline and 3 months; SCD subjects were additionally tested at 6 months. An important facet of our study was the development and use of a novel QST modelling approach, allowing us to model all data together across modalities. We have not demonstrated significant differences in thermal thresholds between subjects with SCD and controls. Thermal thresholds were consistent over a 3- to 6-month period. Subjects on whom hydroxycarbamide (HC) was initiated shortly before or after baseline testing (new HC users) exhibited progressive decreases in thermal sensitivity from baseline to 6 months, suggesting that thermal testing may be sensitive to effective therapy to prevent vasoocclusive pain. These findings inform the use of QST as an endpoint in the evaluation of preventative pain therapies

    Chandra and Swift observations of the quasi-persistent neutron star transient EXO 0748-676 back to quiescence

    Full text link
    The quasi-persistent neutron star X-ray transient and eclipsing binary EXO 0748-676 recently started the transition to quiescence following an accretion outburst that lasted more than 24 years. We report on two Chandra and twelve Swift observations performed within five months after the end of the outburst. The Chandra spectrum is composed of a soft, thermal component that fits to a neutron star atmosphere model with kT^inf~0.12 keV, joined by a hard powerlaw tail that contributes ~20% of the total 0.5-10 keV unabsorbed flux. The combined Chandra/Swift data set reveals a relatively hot and luminous quiescent system with a temperature of kT^inf~0.11-0.13 keV and a bolometric thermal luminosity of ~8.1E33-1.6E34 (d/7.4 kpc)^2 erg/s. We discuss our results in the context of cooling neutron star models.Comment: Accepted for publication in MNRAS Letters, moderate revision according to referee report, added one plot to figure 2 and included new Swift observations, 5 pages, 2 figure
    corecore