5,767 research outputs found
Knowledge, attitudes, and behavior concerning dental trauma among parents of children attending primary school
BACKGROUND: Traumatic dental injuries occur frequently in children and adolescents. The purpose of the present study is to examine the levels of knowledge and behaviors regarding dental trauma among parents of children attending primary schools in the Apulia region of Italy.
METHODS: The study was carried out using an anonymous questionnaire with closed answers distributed to 2,775 parents who were enrolled based on the entire regional school population. Analyses were conducted using the PROC CORRESP (procedure to perform multiple correspondence analysis) and PROC FASTCLUS (procedure to perform cluster analysis). Statistical significance was set at p-value <0.05.
RESULTS: A total 15.5% of the sample reported that their children had experienced dental trauma. Overall, 53.8% of respondents stated that they knew what to do in cases of dental injury. Regarding the time limit within which it is possible to usefully intervene for dental trauma, 56.8% of respondents indicated "within 30 minutes". Of the total sample, 56.5% knew how to preserve a displaced tooth. A total 62.9% of parents felt it was appropriate for their children to use dental guards during sports activities. The multivariate analysis showed that wrong knowledge are distributed among all kinds of subject. Parents with previous experience of dental trauma referred right behaviours, instead weak knowledge and wrong behaviours are associated with parents that easily worried for dental events.
CONCLUSIONS: This study showed that most parents reported no experience of dental trauma in their children, and half of them did not know what to do in case of traumatic dental injury and they would intervene within 30 minutes, suggesting that dental trauma may trigger panic. However, they did not have the information needed to best assist the affected child. Motivating parents to assume a preventive approach towards dental trauma may produce positive changes that would result an increase of long-term health benefits among both parents and children
Individuazione del rischio di fallimento via panel analysis
Obiettivo del presente lavoro \ue8 la calibrazione di un metodo di stima della probabilit\ue0 di insolvenza per le imprese manifatturiere di dimensioni medio-grandi. Dopo aver verificato il grado di adeguatezza del modello Z-score di Altman su un particolare collettivo di riferimento, si affronteranno alcune note criticit\ue0 di tale approccio, dalla equipartizione della numerosit\ue0 dei sottocampioni fino alla selezione di nuove variabili esplicative dell\u2019insolvenza. Ai fini della definizione di un nuovo modello, un approccio di stima di tipo panel ad effetti fissi consentir\ue0 la identificazione di variabili esplicative della probabilit\ue0 di default diverse, e peraltro in numero inferiore, rispetto a quelle dei modelli \ue0 la Altman ed un considerevole abbattimento dell\u2019errore di previsione
Muon Capture on the Proton and Deuteron
By measuring the lifetime of the negative muon in pure protium (hydrogen-1),
the MuCap experiment determines the rate of muon capture on the proton, from
which the proton's pseudoscalar coupling g_p may be inferred. A precision of
15% for g_p has been published; this is a step along the way to a goal of 7%.
This coupling can be calculated precisely from heavy baryon chiral perturbation
theory and therefore permits a test of QCD's chiral symmetry. Meanwhile, the
MuSun experiment is in its final design stage; it will measure the rate of muon
capture on the deuteron using a similar technique. This process can be related
through pionless effective field theory and chiral perturbation theory to other
two-nucleon reactions of astrophysical interest, including proton-proton fusion
and deuteron breakup.Comment: Submitted to the proceedings of the 2007 Advanced Studies Institute
on Symmetries and Spin (SPIN-Praha-2007
Deoxynivalenol content in italian organic durum wheat: Results of a six-year survey
Deoxynivalenol (DON) contamination was investigated of Italian durum wheat from organic agriculture. A number of 661 samples from 13 genotypes were collected within the national organic durum wheat network variety trials during the six-year period between 2007–2012 in five different growing areas across Italy (Northern Italy, Marches, Central Apennines, West-Central Italy, Apulia). Mean temperatures and total rainfalls in April, May and June were collected nearby the study sites. Average DON contamination value along the whole study period was 67 μg/kg, and DON was detected only in 36% of the samples. Noteworthy, 95% of the analyzed grain revealed a DON contamination lower than 334 μg/kg. Maximum allowed DON level for unprocessed durum wheat set by European Union (1750 μg/kg) was exceeded only in four samples (0.6%). The highest mean DON values were detected in Northern Italy (175 μg/kg) and Marches (131 μg/kg). The same was for the percentage of positive samples (80% and 58%, respectively). Lower mean values and percentages of contaminated samples were found in West-Central Italy (22 μg/kg and 29%, respectively), Apennines (3 μg/kg and 8%, respectively) and Apulia (2 μg/kg and 7%, respectively). Statistical analysis (Generalized Linear Model, GLZ) was carried out to highlight the effect of factors like cultivation year, growing area and genotype. It revealed a huge effect of year, growing areas and their interaction, while the effect of genotype resulted significantly but quite less than the other main factors. The effect of the year could be explained by climatic data, which suggested an influence of rainfall and temperature at heading on both DON concentration values and percentage of contaminated samples. Results of this study put in evidence a low DON contamination in Italian organic durum wheat
Effects of the timolol-dorzolamide fixed combination and latanoprost on circadian diastolic ocular perfusion pressure in glaucoma.
PURPOSE. To evaluate the effect of the timolol-dorzolamide
fixed combination (TDFC) and latanoprost 0.005% on 24-hour
intraocular pressure (IOP), systolic (SBP) and diastolic (DBP)
blood pressure, and diastolic ocular perfusion pressure (DOPP)
in patients with primary open-angle glaucoma (POAG).
METHODS. This was an institutional, randomized clinical trial.
After a 24-hour assessment without treatment, 27 previously
untreated patients with POAG were randomized to 6 weeks’
treatment with twice-daily TDFC (8 AM and 8 PM) followed by
once-daily latanoprost 0.005% (8 PM), or vice versa. One eye
was analyzed per patient. The mean values of IOP, DBP, SBP,
and DOPP (difference between DBP and IOP) were recorded at
each time point, and the 24-hour data are the mean values of
each patient’s measurements over the 24-hour period. The
differences between the values of the first treatment period
and the baseline and the second treatment period and washout
were calculated and analyzed by means of an analysis of variance
model that tested the effects of sequence and treatment.
RESULTS. Both treatments significantly reduced 24-hour IOP
(P <0.0001), but TDFC led to lower 24-hour pressure
(mean ±SD: 15.4 ±1.9 vs. 16.7± 1.7 mm Hg; P=0.004).
Latanoprost did not lead to any significant reduction in mean
24-hour SBP and DBP (SBP: P =0.952; DBP: P=0.831), but
TDFC did (SBP and DBP: P < 0.0001). Both treatments significantly
increased 24-hour DOPP (P < 0.0001), with no difference
between the two medications (P=0.09).
CONCLUSIONS. In previously untreated patients with POAG, TDFC,
and latanoprost equally enhanced 24-hour DOPP: the former by
counteracting the decrease in DBP with a substantial reduction in
IOP and the latter by not affecting DBP and significantly reducing
IO
Novel Scintillating Materials Based on Phenyl-Polysiloxane for Neutron Detection and Monitoring
Neutron detectors are extensively used at many nuclear research facilities
across Europe. Their application range covers many topics in basic and applied
nuclear research: in nuclear structure and reaction dynamics (reaction
reconstruction and decay studies); in nuclear astrophysics (neutron emission
probabilities); in nuclear technology (nuclear data measurements and
in-core/off-core monitors); in nuclear medicine (radiation monitors,
dosimeters); in materials science (neutron imaging techniques); in homeland
security applications (fissile materials investigation and cargo inspection).
Liquid scintillators, widely used at present, have however some drawbacks given
by toxicity, flammability, volatility and sensitivity to oxygen that limit
their duration and quality. Even plastic scintillators are not satisfactory
because they have low radiation hardness and low thermal stability. Moreover
organic solvents may affect their optical properties due to crazing. In order
to overcome these problems, phenyl-polysiloxane based scintillators have been
recently developed at Legnaro National Laboratory. This new solution showed
very good chemical and thermal stability and high radiation hardness. The
results on the different samples performance will be presented, paying special
attention to a characterization comparison between synthesized phenyl
containing polysiloxane resins where a Pt catalyst has been used and a
scintillating material obtained by condensation reaction, where tin based
compounds are used as catalysts. Different structural arrangements as a result
of different substituents on the main chain have been investigated by High
Resolution X-Ray Diffraction, while the effect of improved optical
transmittance on the scintillation yield has been elucidated by a combination
of excitation/fluorescence measurements and scintillation yield under exposure
to alpha and {\gamma}-rays.Comment: InterM 2013 - International Multidisciplinary Microscopy Congres
Columbus Payloads Flow Rate Anomalies
The Columbus Active Thermal Control System (ATCS) is the main thermal bus for the pressurized racks working inside the European laboratory. One of the ATCS goals is to provide proper water flow rate to each payload (P/L) by controlling actively the pressure drop across the common plenum distribution piping. Overall flow measurement performed by the Water Pump Assembly (WPA) is the only flow rate monitor available at system level and is not part of the feedback control system. At rack activation the flow rate provided by the system is derived on ground by computing the WPA flow increase. With this approach, several anomalies were raised during these 3 years on-orbit, with the indication of low flow rate conditions on the European racks FSL, BioLab, EDR and EPM. This paper reviews the system and P/Ls calibration approach, the anomalies occurred, the engineering evaluation on the measurement approach and the accuracy improvements proposed, the on-orbit test under evaluation with NASA and finally discusses possible short and long term solutions in case of anomaly confirmation
Le varietà di sorgo da granella consigliate per le semine 2017
Nel 33º anno di prove di confronto tra ibridi di sorgo da granella sono stati realizzati 5 campi sperimentali, 2 nel Nord, 2 in Italia centrale e 1 in Sicilia. Le rese medie sono risultate simili a quelle del 2015, pur con notevoli differenze tra i diversi areali di coltivazion
- …
