43 research outputs found

    Development of sentinel node localization and ROLL in breast cancer in Europe

    Get PDF
    The concept of a precise region in which to find the lymph nodes that drain the lymph directly from the primary tumor site can be traced back to a century ago to the observations of Jamieson and Dobson who described how cancer cells spread from cancer of the stomach in a single lymph node, which they called the â\u80\u9cprimary glandâ\u80\u9d. However, Cabanas was the first in 1977 to realize the importance of this concept in clinical studies following lymphography performed in patients with penile cancer. Thanks to Mortonâ\u80\u99s studies on melanoma in 1992, we began to understand the potential impact of the sentinel lymph node (SN) on the surgical treatment of this type of cancer. The use of a vital dye (blue dye) administered subdermally in the region surrounding the melanoma lesion led to the identification of the sentinel node, and the vital dye technique was subsequently applied to other types of solid tumors, e.g. breast, vulva. However, difficulties in using this technique in anatomical regions with deep lymphatic vessels, e.g. axilla, led to the development of lymphoscintigraphy, started by Alex and Krag in 1993 on melanoma and breast cancer and optimized by our group at European Institute of Oncology (IEO) in Milan in 1996. Today, lymphoscintigraphy is still considered as the most reliable method for the detection of the SN. In 1996, a new method for the localization of non-palpable breast lesion called radioguided occult lesion localization (ROLL) was also developed at IEO. Retrospective and prospective studies have since shown that the ROLL procedure permits the easy and accurate surgical removal of non-palpable breast lesions, overcoming the limitations of previous techniques such as the wire-guided localization. The purpose of this paper is to describe the evolution of SN biopsy and radioguided surgery in the management of breast cancer. We also include a review of the literature on the clinical scenarios in which SN biopsy in breast cancer is currently used, with particular reference to controversies and future prospects

    A new growth chart for preterm babies: Babson and Benda's chart updated with recent data and a new format

    Get PDF
    BACKGROUND: The Babson and Benda 1976 "fetal-infant growth graph" for preterm infants is commonly used in neonatal intensive care. Its limits include the small sample size which provides low confidence in the extremes of the data, the 26 weeks start and the 500 gram graph increments. The purpose of this study was to develop an updated growth chart beginning at 22 weeks based on a meta-analysis of published reference studies. METHODS: The literature was searched from 1980 to 2002 for more recent data to complete the pre and post term sections of the chart. Data were selected from population studies with large sample sizes. Comparisons were made between the new chart and the Babson and Benda graph. To validate the growth chart the growth results from the National Institute of Child Health and Human Development Neonatal Research Network (NICHD) were superimposed on the new chart. RESULTS: The new data produced curves that generally followed patterns similar to the old growth graph. Mean differences between the curves of the two charts reached statistical significance after term. Babson's 10(th )percentiles fell between the new data percentiles: the 5th to 17th for weight, the 5th and 15th for head circumference, and the 6th and 16th for length. The growth patterns of the NICHD infants deviated away from the curves of the chart in the first weeks after birth. When the infants reached an average weight of 2 kilograms, those with a birthweight in the range of 700 to 1000 grams had achieved greater than the 10(th )percentile on average for head growth, but remained below the 3(rd )percentile for weight and length. CONCLUSION: The updated growth chart allows a comparison of an infant's growth first with the fetus as early as 22 weeks and then with the term infant to 10 weeks. Comparison of the size of the NICHD infants at a weight of 2 kilograms provides evidence that on average preterm infants are growth retarded with respect to weight and length while their head size has caught up to birth percentiles. As with all meta-analyses, the validity of this growth chart is limited by the heterogeneity of the data sources. Further validation is needed to illustrate the growth patterns of preterm infants to older ages

    A comprehensive overview of radioguided surgery using gamma detection probe technology

    Get PDF
    The concept of radioguided surgery, which was first developed some 60 years ago, involves the use of a radiation detection probe system for the intraoperative detection of radionuclides. The use of gamma detection probe technology in radioguided surgery has tremendously expanded and has evolved into what is now considered an established discipline within the practice of surgery, revolutionizing the surgical management of many malignancies, including breast cancer, melanoma, and colorectal cancer, as well as the surgical management of parathyroid disease. The impact of radioguided surgery on the surgical management of cancer patients includes providing vital and real-time information to the surgeon regarding the location and extent of disease, as well as regarding the assessment of surgical resection margins. Additionally, it has allowed the surgeon to minimize the surgical invasiveness of many diagnostic and therapeutic procedures, while still maintaining maximum benefit to the cancer patient. In the current review, we have attempted to comprehensively evaluate the history, technical aspects, and clinical applications of radioguided surgery using gamma detection probe technology
    corecore