3,890 research outputs found

    A Sterile Neutrino Search with Kaon Decay-at-rest

    Full text link
    Monoenergetic muon neutrinos (235.5 MeV) from positive kaon decay-at-rest are considered as a source for an electron neutrino appearance search. In combination with a liquid argon time projection chamber based detector, such a source could provide discovery-level sensitivity to the neutrino oscillation parameter space indicative of a sterile neutrino. Current and future intense >3 GeV kinetic energy proton facilities around the world can be employed for this experimental concept.Comment: 6 pages, 6 figure

    Sterile Neutrino Fits to Short Baseline Neutrino Oscillation Measurements

    Get PDF
    This paper reviews short baseline oscillation experiments as interpreted within the context of one, two, and three sterile neutrino models associated with additional neutrino mass states in the ~1 eV range. Appearance and disappearance signals and limits are considered. We show that fitting short baseline data sets to a (3+3) model, defined by three active and three sterile neutrinos, results in an overall goodness of fit of 67%, and a compatibility of 90% among all data sets -- to be compared to the compatibility of 0.043% and 13% for a (3+1) and a (3+2) model, respectively. While the (3+3) fit yields the highest quality overall, it still finds inconsistencies with the MiniBooNE appearance data sets; in particular, the global fit fails to account for the observed MiniBooNE low-energy excess. Given the overall improvement, we recommend using the results of (3+2) and (3+3) fits, rather than (3+1) fits, for future neutrino oscillation phenomenology. These results motivate the pursuit of further short baseline experiments, such as those reviewed in this paper.Comment: Submitted to Advances in High Energy Physics Special Issue on Neutrino Physic

    Adaptive weight estimator for quantum error correction

    Get PDF
    Quantum error correction of a surface code or repetition code requires the pairwise matching of error events in a space-time graph of qubit measurements, such that the total weight of the matching is minimized. The input weights follow from a physical model of the error processes that affect the qubits. This approach becomes problematic if the system has sources of error that change over time. Here we show how the weights can be determined from the measured data in the absence of an error model. The resulting adaptive decoder performs well in a time-dependent environment, provided that the characteristic time scale τenv\tau_{\mathrm{env}} of the variations is greater than δt/pˉ\delta t/\bar{p}, with δt\delta t the duration of one error-correction cycle and pˉ\bar{p} the typical error probability per qubit in one cycle.Comment: 5 pages, 4 figure

    Measuring Active-to-Sterile Neutrino Oscillations with Neutral Current Coherent Neutrino-Nucleus Scattering

    Full text link
    Light sterile neutrinos have been introduced as an explanation for a number of oscillation signals at Δm21\Delta m^2 \sim 1 eV2^2. Neutrino oscillations at relatively short baselines provide a probe of these possible new states. This paper describes an accelerator-based experiment using neutral current coherent neutrino-nucleus scattering to strictly search for active-to-sterile neutrino oscillations. This experiment could, thus, definitively establish the existence of sterile neutrinos and provide constraints on their mixing parameters. A cyclotron-based proton beam can be directed to multiple targets, producing a low energy pion and muon decay-at-rest neutrino source with variable distance to a single detector. Two types of detectors are considered: a germanium-based detector inspired by the CDMS design and a liquid argon detector inspired by the proposed CLEAR experiment.Comment: 10 pages, 7 figure

    NASA Science4Girls and Their Families: Connecting Local Libraries with NASA Scientists and Education Programs to Engage Girls in STEM

    Get PDF
    NASA Science4Girls and Their Families (NS4G) partners NASA Science Mission Directorate (SMD) education programs with public libraries to provide hands-on science, technology, engineering, and math (STEM) activities and career information for girls and their families, along with training for librarians, in conjunction with Women's History Month (March). NS4G is a collaboration among education teams within the four NASA SMD education and public outreach (E/PO) Forums: Planetary, Earth, Astrophysics, and Heliophysics. It began in 2012 as an Astrophysics-led program (Astro4Girls) with 9 events around the country. Upon expanding among the four Forums, over 73 events were held in Spring 2013 (Fig. 1), with preparations underway for events in Spring 2014. All events are individually evaluated by both the student participants and participating librarians to assess their effectiveness in addressing audience needs

    ArgoNeuT, a liquid argon time projection chamber in a low energy neutrino beam

    Full text link
    ArgoNeuT (Argon Neutrino Test), a NSF/DOE project at Fermilab, is the first LArTPC to go in a low energy neutrino beam and just the second LArTPC to go in a neutrino beam ever. ArgoNeuT sits just upstream of the on-axis MINOS near detector in the NuMI beamline, about 1 km from the target station and 100 m underground. The detector features a 47X40X90 cm (169 L) active volume TPC with a fully contained recirculation and purification system. Among other physics, ArgoNeuT will measure the charged-current quasi-elastic (anti-) neutrino cross section on argon at an energy of ~3 GeV.Comment: 3 pages, 2 figures, to appear in the proceedings of the 11th International Conference on Topics in Astroparticle and Underground Physics (TAUP 2009), Rome, Italy, 1-5 July 200

    Tadpole renormalization and relativistic corrections in lattice NRQCD

    Get PDF
    We make a comparison of two tadpole renormalization schemes in the context of the quarkonium hyperfine splittings in lattice NRQCD. Improved gauge-field and NRQCD actions are analyzed using the mean-link u0,Lu_{0,L} in Landau gauge, and using the fourth root of the average plaquette u0,Pu_{0,P}. Simulations are done for ccˉc\bar c, bcˉb\bar c, and bbˉb\bar b systems. The hyperfine splittings are computed both at leading and at next-to-leading order in the relativistic expansion. Results are obtained at lattice spacings in the range of about 0.14~fm to 0.38~fm. A number of features emerge, all of which favor tadpole renormalization using u0,Lu_{0,L}. This includes much better scaling behavior of the hyperfine splittings in the three quarkonium systems when u0,Lu_{0,L} is used. We also find that relativistic corrections to the spin splittings are smaller when u0,Lu_{0,L} is used, particularly for the ccˉc\bar c and bcˉb\bar c systems. We also see signs of a breakdown in the NRQCD expansion when the bare quark mass falls below about one in lattice units. Simulations with u0,Lu_{0,L} also appear to be better behaved in this context: the bare quark masses turn out to be larger when u0,Lu_{0,L} is used, compared to when u0,Pu_{0,P} is used on lattices with comparable spacings. These results also demonstrate the need to go beyond tree-level tadpole improvement for precision simulations.Comment: 14 pages, 7 figures (minor changes to some phraseology and references

    Demonstrating a directional detector based on neon for characterizing high energy neutrons

    Get PDF
    MITPC is a gas-based time projection chamber used for detecting fast, MeV-scale neutrons. The standard version of the detector relies on a mixture of 600 torr gas composed of 87.5% ⁴He and 12.5% CF₄ for precisely measuring the energy and direction of neutron-induced nuclear recoils. We describe studies performed with a prototype detector investigating the use of Ne, as a replacement for ⁴He, in the gas mixture. Our discussion focuses on the advantages of Ne as the fast neutron target for high energy neutron events (lesssim100 MeV) and a demonstration that the mixture will be effective for this event class. We find that the achievable gain and transverse diffusion of drifting electrons in the Ne mixture are acceptable and that the detector uptime lost due to voltage breakdowns in the amplification plane is negligible, compared to ~ 20% with the ⁴He mixture.National Science Foundation (U.S.) (NSF-PHY- 1505855

    Analysis of a Large Sample of Neutrino-Induced Muons with the ArgoNeuT Detector

    Full text link
    ArgoNeuT, or Argon Neutrino Test, is a 170 liter liquid argon time projection chamber designed to collect neutrino interactions from the NuMI beam at Fermi National Accelerator Laboratory. ArgoNeuT operated in the NuMI low-energy beam line directly upstream of the MINOS Near Detector from September 2009 to February 2010, during which thousands of neutrino and antineutrino events were collected. The MINOS Near Detector was used to measure muons downstream of ArgoNeuT. Though ArgoNeuT is primarily an R&D project, the data collected provide a unique opportunity to measure neutrino cross sections in the 0.1-10 GeV energy range. Fully reconstructing the muon from these interactions is imperative for these measurements. This paper focuses on the complete kinematic reconstruction of neutrino-induced through-going muons tracks. Analysis of this high statistics sample of minimum ionizing tracks demonstrates the reliability of the geometric and calorimetric reconstruction in the ArgoNeuT detector
    corecore