3,890 research outputs found
A Sterile Neutrino Search with Kaon Decay-at-rest
Monoenergetic muon neutrinos (235.5 MeV) from positive kaon decay-at-rest are
considered as a source for an electron neutrino appearance search. In
combination with a liquid argon time projection chamber based detector, such a
source could provide discovery-level sensitivity to the neutrino oscillation
parameter space indicative of a sterile neutrino. Current and future intense >3
GeV kinetic energy proton facilities around the world can be employed for this
experimental concept.Comment: 6 pages, 6 figure
Sterile Neutrino Fits to Short Baseline Neutrino Oscillation Measurements
This paper reviews short baseline oscillation experiments as interpreted
within the context of one, two, and three sterile neutrino models associated
with additional neutrino mass states in the ~1 eV range. Appearance and
disappearance signals and limits are considered. We show that fitting short
baseline data sets to a (3+3) model, defined by three active and three sterile
neutrinos, results in an overall goodness of fit of 67%, and a compatibility of
90% among all data sets -- to be compared to the compatibility of 0.043% and
13% for a (3+1) and a (3+2) model, respectively. While the (3+3) fit yields the
highest quality overall, it still finds inconsistencies with the MiniBooNE
appearance data sets; in particular, the global fit fails to account for the
observed MiniBooNE low-energy excess. Given the overall improvement, we
recommend using the results of (3+2) and (3+3) fits, rather than (3+1) fits,
for future neutrino oscillation phenomenology. These results motivate the
pursuit of further short baseline experiments, such as those reviewed in this
paper.Comment: Submitted to Advances in High Energy Physics Special Issue on
Neutrino Physic
Adaptive weight estimator for quantum error correction
Quantum error correction of a surface code or repetition code requires the
pairwise matching of error events in a space-time graph of qubit measurements,
such that the total weight of the matching is minimized. The input weights
follow from a physical model of the error processes that affect the qubits.
This approach becomes problematic if the system has sources of error that
change over time. Here we show how the weights can be determined from the
measured data in the absence of an error model. The resulting adaptive decoder
performs well in a time-dependent environment, provided that the characteristic
time scale of the variations is greater than , with the duration of one error-correction cycle and
the typical error probability per qubit in one cycle.Comment: 5 pages, 4 figure
Measuring Active-to-Sterile Neutrino Oscillations with Neutral Current Coherent Neutrino-Nucleus Scattering
Light sterile neutrinos have been introduced as an explanation for a number
of oscillation signals at eV. Neutrino oscillations at
relatively short baselines provide a probe of these possible new states. This
paper describes an accelerator-based experiment using neutral current coherent
neutrino-nucleus scattering to strictly search for active-to-sterile neutrino
oscillations. This experiment could, thus, definitively establish the existence
of sterile neutrinos and provide constraints on their mixing parameters. A
cyclotron-based proton beam can be directed to multiple targets, producing a
low energy pion and muon decay-at-rest neutrino source with variable distance
to a single detector. Two types of detectors are considered: a germanium-based
detector inspired by the CDMS design and a liquid argon detector inspired by
the proposed CLEAR experiment.Comment: 10 pages, 7 figure
NASA Science4Girls and Their Families: Connecting Local Libraries with NASA Scientists and Education Programs to Engage Girls in STEM
NASA Science4Girls and Their Families (NS4G) partners NASA Science Mission Directorate (SMD) education programs with public libraries to provide hands-on science, technology, engineering, and math (STEM) activities and career information for girls and their families, along with training for librarians, in conjunction with Women's History Month (March). NS4G is a collaboration among education teams within the four NASA SMD education and public outreach (E/PO) Forums: Planetary, Earth, Astrophysics, and Heliophysics. It began in 2012 as an Astrophysics-led program (Astro4Girls) with 9 events around the country. Upon expanding among the four Forums, over 73 events were held in Spring 2013 (Fig. 1), with preparations underway for events in Spring 2014. All events are individually evaluated by both the student participants and participating librarians to assess their effectiveness in addressing audience needs
ArgoNeuT, a liquid argon time projection chamber in a low energy neutrino beam
ArgoNeuT (Argon Neutrino Test), a NSF/DOE project at Fermilab, is the first
LArTPC to go in a low energy neutrino beam and just the second LArTPC to go in
a neutrino beam ever. ArgoNeuT sits just upstream of the on-axis MINOS near
detector in the NuMI beamline, about 1 km from the target station and 100 m
underground. The detector features a 47X40X90 cm (169 L) active volume TPC with
a fully contained recirculation and purification system. Among other physics,
ArgoNeuT will measure the charged-current quasi-elastic (anti-) neutrino cross
section on argon at an energy of ~3 GeV.Comment: 3 pages, 2 figures, to appear in the proceedings of the 11th
International Conference on Topics in Astroparticle and Underground Physics
(TAUP 2009), Rome, Italy, 1-5 July 200
Tadpole renormalization and relativistic corrections in lattice NRQCD
We make a comparison of two tadpole renormalization schemes in the context of
the quarkonium hyperfine splittings in lattice NRQCD. Improved gauge-field and
NRQCD actions are analyzed using the mean-link in Landau gauge, and
using the fourth root of the average plaquette . Simulations are done
for , , and systems. The hyperfine splittings are
computed both at leading and at next-to-leading order in the relativistic
expansion. Results are obtained at lattice spacings in the range of about
0.14~fm to 0.38~fm. A number of features emerge, all of which favor tadpole
renormalization using . This includes much better scaling behavior of
the hyperfine splittings in the three quarkonium systems when is
used. We also find that relativistic corrections to the spin splittings are
smaller when is used, particularly for the and
systems. We also see signs of a breakdown in the NRQCD expansion when the bare
quark mass falls below about one in lattice units. Simulations with
also appear to be better behaved in this context: the bare quark masses turn
out to be larger when is used, compared to when is used on
lattices with comparable spacings. These results also demonstrate the need to
go beyond tree-level tadpole improvement for precision simulations.Comment: 14 pages, 7 figures (minor changes to some phraseology and
references
Demonstrating a directional detector based on neon for characterizing high energy neutrons
MITPC is a gas-based time projection chamber used for detecting fast, MeV-scale neutrons. The standard version of the detector relies on a mixture of 600 torr gas composed of 87.5% ⁴He and 12.5% CF₄ for precisely measuring the energy and direction of neutron-induced nuclear recoils. We describe studies performed with a prototype detector investigating the use of Ne, as a replacement for ⁴He, in the gas mixture. Our discussion focuses on the advantages of Ne as the fast neutron target for high energy neutron events (lesssim100 MeV) and a demonstration that the mixture will be effective for this event class. We find that the achievable gain and transverse diffusion of drifting electrons in the Ne mixture are acceptable and that the detector uptime lost due to voltage breakdowns in the amplification plane is negligible, compared to ~ 20% with the ⁴He mixture.National Science Foundation (U.S.) (NSF-PHY- 1505855
Analysis of a Large Sample of Neutrino-Induced Muons with the ArgoNeuT Detector
ArgoNeuT, or Argon Neutrino Test, is a 170 liter liquid argon time projection
chamber designed to collect neutrino interactions from the NuMI beam at Fermi
National Accelerator Laboratory. ArgoNeuT operated in the NuMI low-energy beam
line directly upstream of the MINOS Near Detector from September 2009 to
February 2010, during which thousands of neutrino and antineutrino events were
collected. The MINOS Near Detector was used to measure muons downstream of
ArgoNeuT. Though ArgoNeuT is primarily an R&D project, the data collected
provide a unique opportunity to measure neutrino cross sections in the 0.1-10
GeV energy range. Fully reconstructing the muon from these interactions is
imperative for these measurements. This paper focuses on the complete kinematic
reconstruction of neutrino-induced through-going muons tracks. Analysis of this
high statistics sample of minimum ionizing tracks demonstrates the reliability
of the geometric and calorimetric reconstruction in the ArgoNeuT detector
- …