4,200 research outputs found
Geologic context of geodetic data across a Basin and Range normal fault, Crescent Valley, Nevada
Geodetic strain and late Quaternary faulting in the Basin and Range province is distributed over a region much wider than historic seismicity, which is localized near the margins of the province. In the relatively aseismic interior, both the magnitude and direction of geodetic strain may be inconsistent with the Holocene faulting record. We document the best example of such a disagreement across the NE striking, ~55° NW dipping Crescent normal fault, where a NW oriented, 70 km geodetic baseline records contemporary shortening of ~2 mm/yr orthogonal to the fault trace. In contrast, our geomorphic, paleoseismic, and geochronologic analyses of the Crescent fault suggest that a large extensional rupture occurred during the late Holocene epoch. An excavation across the fault at Fourmile Canyon reveals that the most recent event occurred at 2.8 ± 0.1 ka, with net vertical tectonic displacement of 4.6 ± 0.4 m at this location, corresponding to the release of ~3 m of accumulated NW-SE extension. Measured alluvial scarp profiles suggest a minimum rupture length of 30 km along the range front for the event, implying a moment magnitude M_w of at least 6.6. No prior event occurred between ~2.8 ka and ~6.4 ± 0.1 ka, the ^(14)C calender age of strata near the base of the exposed section. Assuming typical slip rates for Basin and Range faults (~0.3 mm/yr), these results imply that up to one third, or ~1 m, of the extensional strain released in the previous earthquake could have reaccumulated across the fault since ~2.8 ka. However, the contemporary shortening implies that the fault is unloading due to a transient process, whose duration is limited to between 6 years (geodetic recording time) and 2.8 ka (the age of the most recent event). These results emphasize the importance of providing accurate geologic data on the timescale of the earthquake cycle in order to evaluate geodetic measurements
Profile Guided Dataflow Transformation for FPGAs and CPUs
This paper proposes a new high-level approach for optimising field programmable gate array (FPGA) designs. FPGA designs are commonly implemented in low-level hardware description languages (HDLs), which lack the abstractions necessary for identifying opportunities for significant performance improvements. Using a computer vision case study, we show that modelling computation with dataflow abstractions enables substantial restructuring of FPGA designs before lowering to the HDL level, and also improve CPU performance. Using the CPU transformations, runtime is reduced by 43 %. Using the FPGA transformations, clock frequency is increased from 67MHz to 110MHz. Our results outperform commercial low-level HDL optimisations, showcasing dataflow program abstraction as an amenable computation model for highly effective FPGA optimisation
Recommended from our members
The Health Status and Unique Health Challenges of Rural Older Adults in California
Examines the demographics, health, and levels of physical activity and food insecurity of rural seniors compared with those of urban and suburban seniors. Outlines environmental and social risk factors that require context-specific policies and programs
Profile driven dataflow optimisation of mean shift visual tracking
Profile guided optimisation is a common technique used by compilers and runtime systems to shorten execution runtimes and to optimise locality aware scheduling and memory access on heterogeneous hardware platforms. Some profiling tools trace the execution of low level code, whilst others are designed for abstract models of computation to provide rich domain-specific context in profiling reports. We have implemented mean shift, a computer vision tracking algorithm, in the RVC-CAL dataflow language and use both dynamic runtime and static dataflow profiling mechanisms to identify and eliminate bottlenecks in our naive initial version. We use these profiling reports to tune the CPU scheduler reducing runtime by 88%, and to optimise our dataflow implementation that reduces runtime by a further 43% - an overall runtime reduction of 93%. We also assess the portability of our mean shift optimisations by trading off CPU runtime against resource utilisation on FPGAs. Applying all dataflow optimisations reduces FPGA design space significantly, requiring fewer slice LUTs and less block memory
Power efficient dataflow design for a heterogeneous smart camera architecture
Visual attention modelling characterises the scene to segment regions of visual interest and is increasingly being used as a pre-processing step in many computer vision applications including surveillance and security. Smart camera architectures are an emerging technology and a foundation of security and safety frameworks in modern vision systems. In this paper, we present a dataflow design of a visual saliency based camera architecture targeting a heterogeneous CPU+FPGA platform to propose a smart camera network infrastructure. The proposed design flow encompasses image processing algorithm implementation, hardware & software integration and network connectivity through a unified model. By leveraging the properties of the dataflow paradigm, we iteratively refine the algorithm specification into a deployable solution, addressing distinct requirements at each design stage: from algorithm accuracy to hardware-software interactions, real-time execution and power consumption. Our
design achieved real-time run time performance and the power
consumption of the optimised asynchronous design is reported at only 0.25 Watt. The resource usages on a Xilinx Zynq platform remains significantly low
Inkjet printed LED based pH chemical sensor for gas sensing
Predictable behaviour is a critical factor when developing a sensor for potential deployment within a wireless sensor network (WSN). The work presented here details the fabrication and performance of an optical chemical sensor for gaseous acetic acid analysis, which was constructed using inkjet printed deposition of a colorimetric chemical sensor. The chemical sensor comprised a pH indicator dye (bromophenol blue), phase transfer salt tetrahexylammonium bromide and polymer ethyl cellulose dissolved in 1-butanol. A paired emitter-detector diode (PEDD) optical detector was employed to monitor responses of the colorimetric chemical sensor as it exhibits good sensitivity, low power consumption, is low cost, accurate and has excellent signal to noise ratios. The chemical sensor formulation was printed directly onto the surface the emitter LED, and the resulting chemical sensors characterised with respect to their layer thickness, response time and recovery time. The fabrication reproducibility of inkjet printed chemical sensors in comparison to drop casted chemical sensors was investigated. Colorimetric chemical sensors produced by inkjet printing, exhibited an improved reproducibility for the detection of gaseous acetic acid with a relative standard deviation of 5.5 % in comparison to 68.0 % calculated for drop casted sensors (n = 10). The stability of the chemical sensor was also investigated through both intra and inter-day studies
A study of the interacting binary V 393 Scorpii
We present high resolution J-band spectroscopy of V 393 Sco obtained with the
CRIRES at the ESO Paranal Observatory along with a discussion of archival IUE
spectra and published broad band magnitudes. The best fit to the spectral
energy distribution outside eclipse gives = 19000 500 for the
gainer, = 7250 300 for the donor, = 0.13 0.02
mag. and a distance of = 523 60 pc, although circumstellar material
was not considered in the fit. We argue that V 393 Sco is not a member of the
open cluster M7. The shape of the He I 1083 nm line shows orbital modulations
that can be interpreted in terms of an optically thick pseudo-photosphere
mimicking a hot B-type star and relatively large equatorial mass loss through
the Lagrangian L3 point during long cycle minimum. IUE spectra show several
(usually asymmetric) absorption lines from highly ionized metals and a narrow
L emission core on a broad absorption profile. The overall behavior of
these lines suggests the existence of a wind at intermediate latitudes. From
the analysis of the radial velocities we find = 0.24 0.02
and a mass function of = 4.76 0.24 M. Our observations favor
equatorial mass loss rather than high latitude outflows as the cause for the
long variability.Comment: 13 pages, 14 figures, 7 tables. Accepted for publication in MNRAS,
main journa
Recommended from our members
Personalized versus standardized dosing strategies for the treatment of childhood amblyopia: study protocol for a randomized controlled trial
Background: Amblyopia is the commonest visual disorder of childhood in Western societies, affecting, predominantly,
spatial visual function. Treatment typically requires a period of refractive correction (‘optical treatment’) followed by occlusion: covering the nonamblyopic eye with a fabric patch for varying daily durations. Recent studies have provided insight into the optimal amount of patching (‘dose’), leading to the adoption of standardized dosing strategies, which, though an advance on previous ad-hoc regimens, take little account of individual patient characteristics. This trial compares the effectiveness of a standardized dosing strategy (that is, a fixed daily occlusion dose based on disease severity) with a personalized dosing strategy (derived from known treatment dose-response functions), in which an initially prescribed occlusion dose is modulated, in a systematic manner, dependent on treatment compliance.
Methods/design: A total of 120 children aged between 3 and 8 years of age diagnosed with amblyopia in association with either anisometropia or strabismus, or both, will be randomized to receive either a standardized or a personalized occlusion dose regimen. To avoid confounding by the known benefits of refractive correction, participants will not be randomized until they have completed an optical treatment phase. The primary study objective is to determine whether, at trial endpoint, participants receiving a personalized dosing strategy require fewer hours of occlusion than those in receipt of a standardized dosing strategy. Secondary objectives are to quantify the relationship between
observed changes in visual acuity (logMAR, logarithm of the Minimum Angle of Resolution) with age, amblyopia type, and severity of amblyopic visual acuity deficit.
Discussion: This is the first randomized controlled trial of occlusion therapy for amblyopia to compare a treatment arm representative of current best practice with an arm representative of an entirely novel treatment regimen based on statistical modelling of previous trial outcome data. Should the personalized dosing strategy demonstrate superiority over the standardized dosing strategy, then its adoption into routine practice could bring practical benefits in reducing the duration of treatment needed to achieve an optimal outcome
Randomised controlled trial of video clips and interactive games to improve vision in children with amblyopia using the I-BiT system
Background Traditional treatment of amblyopia involves either wearing a patch or atropine penalisation of the better eye. A new treatment is being developed on the basis of virtual reality technology allowing either DVD footage or computer games which present a common background to both eyes and the foreground, containing the imagery of interest, only to the amblyopic eye.
Methods A randomised control trial was performed on patients with amblyopia aged 4–8 years with three arms. All three arms had dichoptic stimulation using shutter glass technology. One arm had DVD footage shown to the amblyopic eye and common background to both, the second used a modified shooter game, Nux, with sprite and targets presented to the amblyopic eye (and background to both) while the third arm had both background and foreground presented to both eyes (non-interactive binocular treatment (non-I-BiT) games).
Results Seventy-five patients were randomised; 67 were residual amblyopes and 70 had an associated strabismus. The visual acuity improved in all three arms by approximately 0.07 logMAR in the amblyopic eye at 6 weeks. There was no difference between I-BiT DVD and non-I-BiT games compared with I-BiT games (stated primary outcome) in terms of gain in vision.
Conclusions There was a modest vision improvement in all three arms. Treatment was well tolerated and safe. There was no difference between the three treatments in terms of primary stated outcomes but treatment duration was short and the high proportion of previously treated amblyopia and strabismic amblyopia disadvantaged dichoptic stimulation treatment
- …
