114 research outputs found

    Clothing insulation and temperature, layer and mass of clothing under comfortable environmental conditions

    Get PDF
    This study was designed to investigate the relationship between the microclimate temperature and clothing insulation (Icl) under comfortable environmental conditions. In total, 20 subjects (13 women, 7 men) took part in this study. Four environmental temperatures were chosen: 14??C (to represent March/April), 25??C (May/June), 29??C (July/August), and 23??C (September/October). Wind speed (0.14ms-1) and humidity (45%) were held constant. Clothing microclimate temperatures were measured at the chest (Tchest) and on the interscapular region (Tscapular). Clothing temperature of the innermost layer (Tinnermost) was measured on this layer 30 mm above the centre of the left breast. Subjects were free to choose the clothing that offered them thermal comfort under each environmental condition. We found the following results. 1) All clothing factors except the number of lower clothing layers (Llower), showed differences between the different environmental conditions (P<0.05). The ranges of Tchest were 31.6 to 33.5??C and 32.2 to 33.4??C in Tscapular. The range of Tinnermost was 28.6 to 32.0??C. The range of the upper clothing layers (Lupper) and total clothing mass (Mtotal) was 1.1 to 3.2 layers and 473 to 1659 g respectively. The range of Icl was 0.78 to 2.10 clo. 2) Post hoc analyses showed that analysis of Tinnermost produced the same results as for that of Icl. Likewise, the analysis of Lupper produced the same result as the analysis of the number of total layers (Ltotal) within an outfit. 3) Air temperature (ta) had positive relationships with Tchest and Tscapular and with Tinnermost but had inverse correlations with Icl, Mtotal, Lupper and Ltotal. Tchest, Tscapular, and Tinnermost increased as ta rose. 4) Icl had inverse relationships with Tchest and Tinnermost, but positive relationships with Mtotal, Lupper and Ltotal. Icl could be estimated by Mtotal, Lupper, and Tscapular using a multivariate linear regression model. 5) Lupper had positive relationships with Icl and Mtotal, but Llower did not. Subjects hardly changed Llower under environmental comfort conditions between March and October. This indicates that each of the Tchest, Mtotal, and Lupper was a factor in predicting Icl. Tinnermost might also be a more influential factor than the clothing microclimate temperature.open1

    Clinical significance of soft markers in second trimester ultrasonography for pregnant Korean women: a multicenter study and literature review

    Get PDF
    OBJECTIVE: To evaluate the clinical significance of soft markers for aneuploidy screening in Korean women. METHODS: We retrospectively reviewed the medical records of 5,428 singleton pregnant women who underwent sonography during the second trimester at seven institutions in South Korea. We evaluated the prevalence of the following soft markers: intracardiac echogenic focus, choroid plexus cysts, pyelectasis, echogenic bowel, and mild ventriculomegaly. We developed best-fitted regression equations for the fetal femur and humerus length using our data and defined a short femur and humerus as both long bones below the fifth centile. The results of genetic testing and postnatal outcomes were investigated in patients who had been diagnosed with aforementioned soft markers. RESULTS: The median maternal age of our study population was 33 years, and the median gestational age at the time of ultrasonographic examination was 21 weeks. We detected soft markers in 10.0% (n=540) of fetuses: 9.3% (n=504) were isolated cases and 0.7% (n=36) of cases had two or more markers. We identified only two aneuploides (trisomy 18, 46,XX,t[8;10][q22.1;p13]), of which one was clinically significant. We presented the neonatal outcomes of the fetuses with the respective soft markers. Preterm delivery, low birth weight, and small-for-gestational-age (SGA) were significantly more common in women with a shortened fetal femur (P<0.001, all). However, the presence of a shortened fetal humerus was not associated with those outcomes excluding SGA. CONCLUSION: Soft markers in second-trimester ultrasonography have limited use in screening for fetal aneuploidy in Korean women. However, these markers can be used as a screening tool for adverse outcomes other than chromosomal abnormality

    Summary of clinically diagnosed amniotic fluid embolism cases in Korea and disagreement with 4 criteria proposed for research purpose

    Get PDF
    Objective: This study aimed 1) to investigate the clinical characteristics of amniotic fluid embolism (AFE) cases clinically diagnosed by maternal fetal medicine (MFM) specialists in Korea, 2) to check the disagreement with 4 recently proposed criteria by the Society for Maternal-Fetal Medicine (SMFM) for research purpose, and 3) to compare maternal outcomes between cases satisfying all 4 criteria and cases with at least 1 missing criterion. Methods This study included 12 patients clinically diagnosed with AFE from 7 referral hospitals in Korea. We collected information, including maternal age, symptoms of AFE, the amount of transfusion, and maternal mortality. Results The median maternal age was 33 years (range, 28-40 years). Regarding symptoms, cardiovascular arrest, hypotension, respiratory compromise, clinical coagulopathy, and neurologic signs were observed in 41.7%, 83.3%, 83.3%, 100%, and 66.7% of the cases, respectively. Among the 12 cases, 5 women died and 2 suffered severe neurologic disability, showing an intact survival rate of 41.7%. Disagreement with all 4 criteria proposed by the SMFM was found in 66.7% of the cases, due to the lack of criteria for disseminated intravascular coagulation or strict onset time (<30 minutes after delivery). There was no difference in maternal mortality and the amount of transfusion between cases satisfying all 4 criteria and cases with at least 1 missing criterion. Conclusion Two-thirds of clinically confirmed AFE cases did not satisfy all 4 criteria proposed by the SMFM, despite similar rates of maternal mortality with cases satisfying all 4 criteria. Our study suggests that there may be some discrepancy between the clinical diagnosis of AFE and the recent diagnostic criteria proposed by the SMFM for research purpose

    Perioperative adverse cardiac events and mortality after non-cardiac surgery: a multicenter study

    Get PDF
    Background: Perioperative adverse cardiac events (PACE), a composite of myocardial in-farction, coronary revascularization, congestive heart failure, arrhythmic attack, acute pulmonary embolism, cardiac arrest, and stroke during 30-day postoperative period, is associated with long-term mortality, but with limited clinical evidence. We compared long-term mortality with PACE using data from nationwide multicenter electronic health re-cords. Methods: Data from 7 hospitals, converted to Observational Medical Outcomes Partner-ship Common Data Model, were used. We extracted records of 277,787 adult patients over 18 years old undergoing non-cardiac surgery for the first time at the hospital and had medical records for more than 180 days before surgery. We performed propensity score matching and then an aggregated meta-analysis. Results: After 1:4 propensity score matching, 7,970 patients with PACE and 28,807 patients without PACE were matched. The meta-analysis showed that PACE was associated with higher one-year mortality risk (hazard ratio [HR]: 1.33, 95% CI [1.10, 1.60], P = 0.005) and higher three-year mortality (HR: 1.18, 95% CI [1.01, 1.38], P = 0.038). In sub-group analysis, the risk of one-year mortality by PACE became greater with higher-risk surgical procedures (HR: 1.20, 95% CI [1.04, 1.39], P = 0.020 for low-risk surgery; HR: 1.69, 95% CI [1.45, 1.96], P < 0.001 for intermediate-risk; and HR: 2.38, 95% CI [1.47, 3.86], P = 0.034 for high-risk). Conclusions: A nationwide multicenter study showed that PACE was significantly associated with increased one-year mortality. This association was stronger the older age group, emergency surgery group, and high surgical risk group. Further studies to improve mortality associated with PACE are needed

    Randomized, Controlled, Multi-center Trial: Comparing the Safety and Efficacy of DA-9701 and Itopride Hydrochloride in Patients With Functional Dyspepsia.

    Get PDF
    BACKGROUND/AIMS: Therapies of functional dyspepsia (FD) are limited. DA-9701 is a novel prokinetic agent formulated with Pharbitis semen and Corydalis Tuber. We aimed to assess the efficacy of DA-9701 compared with itopride in FD patients. METHODS: Patients with FD randomly received either itopride 50 mg or DA-9701 30 mg t.i.d after a 2-week baseline period. After 4 weeks of treatment, 2 primary efficacy endpoints were analyzed: the change from baseline in composite score of the 8 dyspep-tic symptoms and the overall treatment effect. Impact on patients' quality of life was assessed using the Nepean Dyspepsia Index (NDI) questionnaire. RESULTS: We randomly assigned 464 patients with 455 having outcome data. The difference of the composite score change of the 8 symptoms between the 2 groups was 0.62, indicating that DA-9701 was not inferior to itopride. The overall treatment effect response rate was not different between the groups. When responder was defined as ≥ 5 of the 7 Likert scale, responder rates were 37% of DA-9701 and 36% of itopride group. Patients receiving DA-9701 experienced similar mean percentage of days with adequate relief during the 4-week treatment period compared with those receiving itopride (56.8% vs 59.1%). Both drugs increased the NDI score of 5 domains without any difference in change of the NDI score between the groups. The safety profile of both drugs was comparable. CONCLUSIONS: DA-9701 significantly improves symptoms in patients with FD. DA-9701 showed non-inferior efficacy to itopride with com-parable safety

    Synthesis and Characterization of ZnO Nanowire–CdO Composite Nanostructures

    Get PDF
    ZnO nanowire–CdO composite nanostructures were fabricated by a simple two-step process involving ammonia solution method and thermal evaporation. First, ZnO nanowires (NWs) were grown on Si substrate by aqueous ammonia solution method and then CdO was deposited on these ZnO NWs by thermal evaporation of cadmium chloride powder. The surface morphology and structure of the synthesized composite structures were analyzed by scanning electron microscopy, X-ray diffraction and transmission electron microscopy. The optical absorbance spectrum showed that ZnO NW–CdO composites can absorb light up to 550 nm. The photoluminescence spectrum of the composite structure does not show any CdO-related emission peak and also there was no band gap modification of ZnO due to CdO. The photocurrent measurements showed that ZnO NW–CdO composite structures have better photocurrent when compared with the bare ZnO NWs

    Addition of Cervical Elastography May Increase Preterm Delivery Prediction Performance in Pregnant Women with Short Cervix: a Prospective Study

    Get PDF
    BACKGROUND: We investigated whether there is a difference in elastographic parameters between pregnancies with and without spontaneous preterm delivery (sPTD) in women with a short cervix (</= 25 mm), and examined the ability of elastographic parameters to predict sPTD in those women. METHODS: E-Cervix(TM) (WS80A: Samsung Medison, Seoul, Korea) elastography was used to examine the cervical strain. Elastographic parameters were compared between pregnancies with and without sPTD. Diagnostic performance of elastographic parameters to predict sPTD </= 37 weeks, both alone and in combination with other parameters, was compared with that of cervical length (CL) using area under receiver operating characteristic curve (AUC) analysis. RESULTS: A total of 130 women were included. Median gestational age (GA) at examination was 24.4 weeks (interquartile range, 21.4-28.9), and the prevalence of sPTD was 20.0% (26/130). Both the elastographic parameters and CL did not show statistical difference between those with and without sPTD. However, when only patients with CL >/= 1.5 cm (n = 110) were included in the analysis, there was a significant difference between two groups in elasticity contrast index (ECI) within 0.5/1.0/1.5 cm from the cervical canal (P /= 1.5 cm, the combination of parameters (CL + pre-pregnancy body mass index + GA at exam + ECI within 0.5/1.0/1.5 cm) showed a significantly higher AUC than CL alone (P < 0.05). CONCLUSION: An addition of cervical elastography may improve the ability to predict sPTD in women with a short CL between 1.5 and 2.5 cm

    Ultrasonographic assessment of abnormal fetal growth related to uteroplacental-fetal biometrics and Doppler (U-AID) indices: Protocol for multicenter retrospective cohort study trial

    Get PDF
    Fetal growth restriction (FGR) is one of the leading causes of perinatal morbidity and mortality. Many studies have reported an association between FGR and fetal Doppler indices focusing on umbilical artery (UA), middle cerebral artery (MCA), and ductus venosus (DV). The uteroplacental-fetal circulation which affects the fetal growth consists of not only UA, MCA, and DV, but also umbilical vein (UV), placenta and uterus itself. Nevertheless, there is a paucity of large-scale cohort studies that have assessed the association between UV, uterine wall, and placental thickness with perinatal outcomes in FGR, in conjunction with all components of the uteroplacental-fetal circulation. Therefore, this multicenter study will evaluate the association among UV absolute flow, placental thickness, and uterine wall thickness and adverse perinatal outcome in FGR fetuses. This multicenter retrospective cohort study will include singleton pregnant women who undergo at least one routine fetal ultrasound scan during routine antepartum care. Pregnant women with fetuses having structural or chromosomal abnormalities will be excluded. The U-AID indices (UtA, UA, MCA, and UV flow, placental and uterine wall thickness, and estimated fetal body weight) will be measured during each trimester of pregnancy. The study population will be divided into two groups: (1) FGR group (pregnant women with FGR fetuses) and (2) control group (those with normal growth fetus). We will assess the association between U-AID indices and adverse perinatal outcomes in the FGR group and the difference in U-AID indices between the two groups
    corecore