255 research outputs found
Noise performance of magneto-inductive cables
Magneto-inductive (MI) waveguides are metamaterial structures based on periodic arrangements of inductively coupled resonant magnetic elements. They are of interest for power transfer, communications and sensing, and can be realised in a flexible cable format. Signal-to-noise ratio is extremely important in applications involving signals. Here, we present the first experimental measurements of the noise performance of metamaterial cables. We focus on an application involving radiofrequency signal transmission in internal magnetic resonance imaging (MRI), where the subdivision of the metamaterial cable provides intrinsic patient safety. We consider MI cables suitable for use at 300 MHz during 1H MRI at 7 T, and find noise figures of 2.3–2.8 dB/m, together with losses of 3.0–3.9 dB/m, in good agreement with model calculations. These values are high compared to conventional cables, but become acceptable when (as here) the environment precludes the use of continuous conductors. To understand this behaviour, we present arguments for the fundamental performance limitations of these cables
Nonlinear magnetoinductive transmission lines
Power transmission in one-dimensional nonlinear magnetic metamaterials driven
at one end is investigated numerically and analytically in a wide frequency
range. The nonlinear magnetic metamaterials are composed of varactor-loaded
split-ring resonators which are coupled magnetically through their mutual
inductances, forming thus a magnetoiductive transmission line. In the linear
limit, significant power transmission along the array only appears for
frequencies inside the linear magnetoinductive wave band. We present
analytical, closed form solutions for the magnetoinductive waves transmitting
the power in this regime, and their discrete frequency dispersion. When
nonlinearity is important, more frequency bands with significant power
transmission along the array may appear. In the equivalent circuit picture, the
nonlinear magnetoiductive transmission line driven at one end by a relatively
weak electromotive force, can be modeled by coupled
resistive-inductive-capacitive (RLC) circuits with voltage-dependent
capacitance. Extended numerical simulations reveal that power transmission
along the array is also possible in other than the linear frequency bands,
which are located close to the nonlinear resonances of a single nonlinear RLC
circuit. Moreover, the effectiveness of power transmission for driving
frequencies in the nonlinear bands is comparable to that in the linear band.
Power transmission in the nonlinear bands occurs through the linear modes of
the system, and it is closely related to the instability of a mode that is
localized at the driven site.Comment: 11 pages, 11 figures, submitted to International Journal of
Bifurcation and Chao
Fabrication and operation of a two-dimensional ion-trap lattice on a high-voltage microchip
Microfabricated ion traps are a major advancement towards scalable quantum computing with trapped ions. The development of more versatile ion-trap designs, in which tailored arrays of ions are positioned in two dimensions above a microfabricated surface, will lead to applications in fields as varied as quantum simulation, metrology and atom–ion interactions. Current surface ion traps often have low trap depths and high heating rates, because of the size of the voltages that can be applied to them, limiting the fidelity of quantum gates. Here we report on a fabrication process that allows for the application of very high voltages to microfabricated devices in general and use this advance to fabricate a two-dimensional ion-trap lattice on a microchip. Our microfabricated architecture allows for reliable trapping of two-dimensional ion lattices, long ion lifetimes, rudimentary shuttling between lattice sites and the ability to deterministically introduce defects into the ion lattice
Metallic foreign body in middle ear: an unusual cause of hearing loss
This is a rare case report of a foreign metallic body found in the middle ear. During the use of an electric welding by a metalworker, a glowing drop of dissolved metal overrun, burning the skin of his external auditory meatus, perforated the tympanic membrane and finally was implanted around the ossicles as a foreign body. Due to difficulty of the physical examination and the moderate symptoms (hearing loss and sense of fullness), the foreign body was detected six months after the incident, by CT scanning and it was removed by a transcanal approach under general anesthesia. A successful ossiculoplasty-tympanoplasty was followed four weeks later
Magneto-inductive magnetic resonance imaging duodenoscope
A magnetic resonance imaging (MRI) duodenoscope is demonstrated, by combining non- magnetic endoscope components with a thin-film receiver based on a magneto-inductive waveguide. The waveguide elements consist of figure-of-eight shaped inductors formed on either side of a flexible substrate and parallel plate capacitors that use the substrate as a dielectric. Operation is simulated using equivalent circuit models and by computation of two- and three-dimensional sensitivity patterns. Circuits are fabricated for operation at 127.7 MHz by double-sided patterning of copper-clad Kapton and assembled onto non-magnetic flexible endoscope insertion tubes. Operation is verified by bench testing and by 1 H MRI at 3T using phantoms. The receiver can form a segmented coaxial image along the length of the endoscope, even when bent, and shows a signal-to-noise-ratio advantage over a surface array coil up to three times the tube diameter at the tip. Initial immersion imaging experiments have been carried out and confirm an encouraging lack of sensitivity to RF heating
Utilizing individual fish biomass and relative abundance models to map environmental niche associations of adult and juvenile targeted fishes
Many fishes undergo ontogenetic habitat shifts to meet their energy and resource needs as they grow. Habitat resource partitioning and patterns of habitat connectivity between conspecific fishes at different life-history stages is a significant knowledge gap. Species distribution models were used to examine patterns in the relative abundance, individual biomass estimates and environmental niche associations of different life stages of three iconic West Australian fishes. Continuous predictive maps describing the spatial distribution of abundance and individual biomass of the study species were created as well predictive hotspot maps that identify possible areas for aggregation of individuals of similar life stages of multiple species (i.e. spawning grounds, fisheries refugia or nursery areas). The models and maps indicate that processes driving the abundance patterns could be different from the body size associated demographic processes throughout an individual's life cycle. Incorporating life-history in the spatially explicit management plans can ensure that critical habitat of the vulnerable stages (e.g. juvenile fish, spawning stock) is included within proposed protected areas and can enhance connectivity between various functional areas (e.g. nursery areas and adult populations) which, in turn, can improve the abundance of targeted species as well as other fish species relying on healthy ecosystem functioning
- …
