201 research outputs found

    A high sensitivity, fast response optical fiber gas sensor using micro-drilled anti-resonant fiber

    Get PDF
    Remote gas detection is often a compromise between high sensitivity and response time. Micro-drilled anti-resonant fiber is used for 0.3% acetylene detection to simultaneously achieve both of these characteristics

    Toward a Harmonization for Using in situ Nutrient Sensors in the Marine Environment

    Get PDF
    Improvedcomparabilityofnutrientconcentrationsinseawaterisrequiredtoenhancethe quality and utility of measurements reported to global databases. Significant progress has been made over recent decades in improving the analysis and data quality for traditional laboratory measurements of nutrients. Similar efforts are required to establish high-quality data outputs from in situ nutrient sensors, which are rapidly becoming integral components of ocean observing systems. This paper suggests using the good practices routine established for laboratory reference methods to propose a harmonized setofdeploymentprotocolsandofqualitycontrolproceduresfornutrientmeasurements obtained from in situ sensors. These procedures are intended to establish a framework to standardize the technical and analytical controls carried out on the three main types of in situ nutrient sensors currently available (wet chemical analyzers, ultraviolet optical sensors, electrochemical sensors) for their deployments on all kinds of platform. The routine reference controls that can be applied to the sensors are listed for each step of sensor use: initial qualification under controlled conditions in the laboratory, preparation of the sensor before deployment, field deployment and finally the sensor recovery. The fundamental principles applied to the laboratory reference method are then reviewed in termsofthecalibrationprotocol,instrumentalinterferences,environmentalinterferences, external controls, and method performance assessment. Data corrections (linearity, sensitivity, drifts, interferences and outliers) are finally identified along with the concepts and calculations for qualification for both real time and time delayed data. This paper emphasizes the necessity of future collaborations between research groups, referenceaccredited laboratories, and technology developers, to maintain comparability of the concentrationsreportedforthevariousnutrientparametersmeasuredbyinsitusensors

    Comparison of Free Light Chain Assays Freelite and N Latex in Diagnosis, Monitoring, and Predicting Survival in Light Chain Amyloidosis

    Get PDF
    OBJECTIVE: Measurement of serum free light chains (FLCs) is critical in diagnosis, prognosis, and monitoring treatment responses in light chain (AL) amyloidosis. We compare the Freelite assay (polyclonal antibodies to hidden light chain epitopes), which is the current gold standard, with a new assay: a mixture of monoclonal antibodies to light chain epitopes (N Latex). METHODS: We collected 240 serum samples from 94 consecutive patients with newly diagnosed AL amyloidosis (at least three serial serum samples during the first 6 months) analyzed at the National Amyloidosis Centre, London, from January 2011 to April 2012. Concordance in detecting abnormal light chain components and hematologic response was assessed at 2, 4, and 6 months. RESULTS: The κ and λ clonal light chain involvement was 21% and 79%, respectively, with an abnormal κ/λ ratio or detectable protein in 78.7%. Median κ, λ, and difference in involved and uninvolved FLCs by Freelite and N Latex assays were 17.3 vs 16 mg/L (R2  = 0.91), 48.8 vs 52.6 mg/L (R2 = 0.52), and 43.2 vs 39.1 mg/L, respectively. Discordant κ/λ ratios at presentation were as follows: 10 of 90 abnormal by Freelite/normal by N Latex and 11 of 90 abnormal by N Latex/normal by Freelite. CONCLUSIONS: Both FLC assays show good correlation in detecting the abnormal light chain subtype with discordance in absolute values and thus are not interchangeable

    Remote Electrical Stimulation by Means of Implanted Rectifiers

    Get PDF
    Miniaturization of active implantable medical devices is currently compromised by the available means for electrically powering them. Most common energy supply techniques for implants – batteries and inductive couplers – comprise bulky parts which, in most cases, are significantly larger than the circuitry they feed. Here, for overcoming such miniaturization bottleneck in the case of implants for electrical stimulation, it is proposed to make those implants act as rectifiers of high frequency bursts supplied by remote electrodes. In this way, low frequency currents will be generated locally around the implant and these low frequency currents will perform stimulation of excitable tissues whereas the high frequency currents will cause only innocuous heating. The present study numerically demonstrates that low frequency currents capable of stimulation can be produced by a miniature device behaving as a diode when high frequency currents, neither capable of thermal damage nor of stimulation, flow through the tissue where the device is implanted. Moreover, experimental evidence is provided by an in vivo proof of concept model consisting of an anesthetized earthworm in which a commercial diode was implanted. With currently available microelectronic techniques, very thin stimulation capsules (diameter <500 µm) deliverable by injection are easily conceivable

    Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation.</p> <p>Hypothesis</p> <p>There is no difference, biomechanically, amongst the various reconstruction and augmentative methods.</p> <p>Study Design</p> <p>Controlled laboratory cadaveric study.</p> <p>Methods</p> <p>54 cadaveric native (acromioclavicular and coracoclavicular) ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1) in the intact states, 2) after modified Weaver-Dunn reconstruction (WD), 3) after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ), 4) after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP) or 5) after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS) and 6) after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt). Posterior-anterior (horizontal) loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005).</p> <p>Results</p> <p>Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p < 0.005).</p> <p>WD.ACJ provided additional posterior-anterior (P = 0. 039) but not superior (p = 0.250) stability when compared to WD alone.</p> <p>WD+PLmt, in loads and stiffness at failure superiorly, was similar to WD+CP (p = 0.066). WD+PLmt, in loads and stiffness at failure postero-anteriorly, was similar to WD+ACJ (p = 0.084).</p> <p>Superiorly, WD+CP had similar strength as WD+BS (p = 0.057), but it was less stiff (p < 0.005).</p> <p>Conclusions and Clinical Relevance</p> <p>Modified Weaver-Dunn procedure must always be supplemented with acromioclavicular capsuloligamentous repair to increase posterior-anterior stability. Palmaris-Longus tendon graft provides both additional superior and posterior-anterior stability when used for acromioclavicular capsuloligamentous reconstruction. It is a good alternative to clavicle hook plate in acromioclavicular dislocation.</p

    Effect of B7.1 Costimulation on T-Cell Based Immunity against TAP-Negative Cancer Can Be Facilitated by TAP1 Expression

    Get PDF
    Tumors deficient in expression of the transporter associated with antigen processing (TAP) usually fail to induce T-cell-mediated immunity and are resistant to T-cell lysis. However, we have found that introduction of the B7.1 gene into TAP-negative (TAP−) or TAP1-transfected (TAP1+) murine lung carcinoma CMT.64 cells can augment the capacity of the cells to induce a protective immune response against wild-type tumor cells. Differences in the strength of the protective immune responses were observed between TAP− and TAP1+ B7.1 expressing CMT.64 cells depending on the doses of γ-irradiated cell immunization. While mice immunized with either high or low dose of B7.1-expressing TAP1+ cells rejected TAP− tumors, only high dose immunization with B7.1-expressing TAP− cells resulted in tumor rejection. The induced protective immunity was T-cell dependent as demonstrated by dramatically reduced antitumor immunity in mice depleted of CD8 or CD4 cells. Augmentation of T-cell mediated immune response against TAP− tumor cells was also observed in a virally infected tumor cell system. When mice were immunized with a high dose of γ-irradiated CMT.64 cells infected with vaccinia viruses carrying B7.1 and/or TAP1 genes, we found that the cells co-expressing B7.1 and TAP1, but not those expressing B7.1 alone, induced protective immunity against CMT.64 cells. In addition, inoculation with live tumor cells transfected with several different gene(s) revealed that only B7.1- and TAP1-coexpressing tumor cells significantly decreased tumorigenicity. These results indicate that B7.1-provoked antitumor immunity against TAP− cancer is facilitated by TAP1-expression, and thus both genes should be considered for cancer therapy in the future

    Functional genomic analysis of drug sensitivity pathways to guide adjuvant strategies in breast cancer

    Get PDF
    The widespread introduction of high throughput RNA interference screening technology has revealed tumour drug sensitivity pathways to common cytotoxics such as paclitaxel, doxorubicin and 5-fluorouracil, targeted agents such as trastuzumab and inhibitors of AKT and Poly(ADP-ribose) polymerase (PARP) as well as endocrine therapies such as tamoxifen. Given the limited power of microarray signatures to predict therapeutic response in associative studies of small clinical trial cohorts, the use of functional genomic data combined with expression or sequence analysis of genes and microRNAs implicated in drug response in human tumours may provide a more robust method to guide adjuvant treatment strategies in breast cancer that are transferable across different expression platforms and patient cohorts

    Perceptions about hemodialysis and transplantation among African American adults with end-stage renal disease: inferences from focus groups

    Get PDF
    BACKGROUND: Disparities in access to kidney transplantation (KT) remain inadequately understood and addressed. Detailed descriptions of patient attitudes may provide insight into mechanisms of disparity. The aims of this study were to explore perceptions of dialysis and KT among African American adults undergoing hemodialysis, with particular attention to age- and sex-specific concerns. METHODS: Qualitative data on experiences with hemodialysis and views about KT were collected through four age- and sex-stratified (males <65, males ≥65, females <65, and females ≥65 years) focus group discussions with 36 African American adults recruited from seven urban dialysis centers in Baltimore, Maryland. RESULTS: Four themes emerged from thematic content analysis: 1) current health and perceptions of dialysis, 2) support while undergoing dialysis, 3) interactions with medical professionals, and 4) concerns about KT. Females and older males tended to be more positive about dialysis experiences. Younger males expressed a lack of support from friends and family. All participants shared feelings of being treated poorly by medical professionals and lacking information about renal disease and treatment options. Common concerns about pursuing KT were increased medication burden, fear of surgery, fear of organ rejection, and older age (among older participants). CONCLUSIONS: These perceptions may contribute to disparities in access to KT, motivating granular studies based on the themes identified
    corecore