Effect of an edge at cup rim on contact stress during micro-separation in ceramic-on-ceramic hip joints
Alumina ceramic total hip joint bearings have shown superior wear properties. The joint bearing may undergo adverse conditions such as micro-separation causing head contact on the cup rim. As a transition, an edge is formed between the cup bearing and the rim. The aim of this study was to predict the effect of the edge on contact stresses in order to better understand the mechanisms of wear. A finite element contact model was developed under the conditions of the head displacements 0.5 2 mm and vertical loads 0.5 3kN. The edge contact produced the most severe stresses capable of causing elevated wear and damage to ceramic bearings. The study shows that the bearing design should be considered in association with clinical conditions to eliminate severe stress
A review of squeaking in ceramic total hip prostheses
The occurrence of audible squeaking in some patients with ceramic-on-ceramic (CoC) hip prostheses is a cause for concern. Considering multifactor contributing to this phenomenon, many studies have been conducted over the last decade. Great efforts have been put on understanding the mechanics of the hip squeaking to gain a deep insight into factors resulting in sound emission from hip articulation. Disruption of fluid-film lubrication and friction were reported as main potential causes of hip squeaking, while patient and surgical factors as well as design and material of hip implants were identified as affecting factors. This review article therefore summarised the recent available literature on this subject to provide a platform for future developments. Moreover, high wear rates and ceramic liner fracture as viable consequences of hip squeaking were discussed.The first author gratefully acknowledges Macquarie University for International Macquarie University Research Excellence Scholarship (iMQRES)-No. 2010017. The second author would like to thank to the Portuguese Foundation for Science and Technology through the project UID/EEA/04436/2013
Total disc replacement for chronic back pain in the presence of disc degeneration
Scientific Assessment and Innovation in Neurosurgical Treatment Strategie
Ceramic on ceramic bearing fractures in total hip arthroplasty : an analysis of data from the national joint registry
Aims: Ceramic-on-ceramic (CoC) bearings in total hip arthroplasty (THA) are commonly used but concerns exist regarding ceramic fracture. This study aims to report the risk of revision for fracture of modern CoC bearings and identify factors that might influence this risk, using data from the National Joint Registry (NJR). Patients and Methods: We analysed data on 111,681 primary CoC THA’s and 182 linked revisions for bearing fracture recorded in NJR. We used implant codes to identify ceramic bearing composition and generated Kaplan-Meier estimates for implant survivorship. Logistic regression analyses were performed for implant size and patient specific variables to determine any associated risks for revision. Results: 99.8% of bearings were CeramTec Biolox® products. Revisions for fracture were linked to 7 of 79,442 (0.009%) Biolox® Delta heads, 38 of 31,982 (0.119%) Biolox® Forte heads, 101 of 80,170 (0.126%) Biolox® Delta liners and 35 of 31,258 (0.112%) Biolox® Forte liners. Regression analysis of implant size revealed smaller heads had significantly higher odds of fracture (χ2=68.0, p<0.0001). The highest fracture risk were observed in the 28mm Biolox® Forte subgroup (0.382%). There were no fractures in the 40mm head group for either ceramic type. Liner thickness was not predictive of fracture (p=0.67). BMI was independently associated with revision for both head fractures (OR 1.09 per unit increase, p=0.031) and liner fractures (OR 1.06 per unit increase, p=0.006). Conclusions: We report the largest study of CoC bearing fractures to date. The risk of revision for CoC bearing fracture is very low, however previous studies have underestimated this risk. There is good evidence that the latest generation of ceramic has greatly reduced the odds of head fracture but not of liner fracture. Small head size and high patient BMI are associated with an increased risk of ceramic bearing fracture
Charcot Spine and Parkinson’s Disease
Charcot spine is rare condition whose association with Parkinson’s disease (PD) has not been reported yet. The authors reported the cases of two patients with PD who developed Charcot spine. Both patients presented with a history of back pain and bilateral radicular leg pain. They had complete clinical and radiological assessment. Lumbar spine was involved in both patients. Clinical features and response to treatment were described. In the first case, circumferential fusion and stabilization were performed on the dislocated vertebral levels. A solid and stable fusion of the spine was obtained with satisfactory clinical outcome. Surgical treatment has been recommended to the other patient. In both cases, no other neurological etiology was found to account for Charcot spine. In conclusion, Charcot spine is associated with several neurological affections but has not previously been reported in association with Parkinson’s disease
Mathematical evaluation of jumping distance in total hip arthroplasty: Influence of abduction angle, femoral head offset, and head diameter
Background and purpose The jumping distance (JD) is the degree of lateral translation of the femoral head center required before dislocation occurs. The smaller the distance, the higher the theoretical risk of dislocation. The aim of our study was to evaluate this jumping distance and its variation according to the characteristics of the implant, and also the theoretical gain in using large head diameters of above 38 mm
Stem torsion in total hip replacement: CT measurements in 60 patients
Methods 60 patients requiring total hip arthroplasty were prospectively enrolled in this study. Minimally invasive THR was performed (anterior approach) in a lateral decubitus position and each patient underwent a postoperative CT examination. The position of the stem was evaluated by an independent external institution. Results Stem torsion ranged from -19 degrees retrotorsion to 33 degrees antetorsion. Normal antetorsion (i.e 10-15 degrees according to Tonnis) was present in 5 of 60 patients, so the prevalence of abnormal stem antetorsion was 92% (95% CI: 82-97). We found a stem antetorsion outside the range of 0-25 degrees in 21 of 60 hips. Women had a higher mean stem antetorsion (8.0 degrees (SD 11)) than men (1.5 degrees (SD 10)). Interpretation Postoperative stem antetorsion shows a high variability and is gender-related. We suggest precise assessment of stem antetorsion intraoperatively by means of computer navigation, preparing the femur first. In abnormal stem antetorsion, the cup position can be adjusted using a combined anteversion concept; alternatively, modular femoral components or stems with retroverted or anteverted necks ("retrostem") could be used
Finite Element Analysis of porously punched prosthetic short stem virtually designed for simulative uncemented Hip Arthroplasty
- …