2,846 research outputs found

    Management of Tuberculosis - The Need to Enforce Proper Treatment Guidelines among Private Practitioners in India

    Get PDF
    Tuberculosis continues to be a daunting challenge for our healthcare system. Even after fifteen years of the much publicised Revised National Tuberculosis Control Programme that envisages directly observed short course chemotherapy (DOTS), TB continues to spread and drug resistant strains, MDR and XDR, are also increasingly reported. More than 50% of TB patients seeking private health care, but the level of awareness regarding treatment of TB among private practitioners appears to be poor. All this call for an urgent revamp of TB control strategy in India

    Intracardiac Calcification - An Interesting Chest X-ray Report.

    Get PDF
    We report a case of chest X-ray finding of mitral annular calcification. Mitral annular calcification is a degenerative process involving the fibrous annulus of the mitral valve. It is generally an incidental finding associated with aging and atherosclerosis. It may lead to significant mitral regurgitation and can rarely cause symptomatic mitral stenosis. In addition, mitral annulus calcification may be associated with atrial fibrillation and cardiac arrhythmia. Calcification of mitral annulus in the chest X-ray generally follows the C-shape of the mitral annulus. Confirmation is by echocardiography. Symptomatic cases require repair by surgery

    Probing anomalous tbW couplings in single-top production using top polarization at the Large Hadron Collider

    Full text link
    We study the sensitivity of the Large Hadron Collider (LHC) to anomalous tbW couplings in single-top production in association with a W^- boson followed by semileptonic decay of the top. We calculate top polarization and the effects of these anomalous couplings to it at two centre-of-mass (cm) energies of 7 TeV and 14 TeV. As a measure of top polarization, we look at various laboratory frame distributions of its decay products, viz., lepton angular and energy distributions and b-quark angular distributions, without requiring reconstruction of the rest frame of the top, and study the effect of anomalous couplings on these distributions. We construct certain asymmetries to study the sensitivity of these distributions to anomalous tbW couplings. We find that 1\sigma limits on real and imaginary parts of the dominant anomalous coupling Ref_{2R} which may be obtained by utilizing these asymmetries at the LHC with cm energy of 14 TeV and an integrated luminosity of 10 fb^{-1} will be significantly better than the expectations from direct measurements of cross sections and some other variables at the LHC and over an order of magnitude better than the indirect limits.Comment: 25 pages, 34 figure

    The relation of steady evaporating drops fed by an influx and freely evaporating drops

    Full text link
    We discuss a thin film evolution equation for a wetting evaporating liquid on a smooth solid substrate. The model is valid for slowly evaporating small sessile droplets when thermal effects are insignificant, while wettability and capillarity play a major role. The model is first employed to study steady evaporating drops that are fed locally through the substrate. An asymptotic analysis focuses on the precursor film and the transition region towards the bulk drop and a numerical continuation of steady drops determines their fully non-linear profiles. Following this, we study the time evolution of freely evaporating drops without influx for several initial drop shapes. As a result we find that drops initially spread if their initial contact angle is larger than the apparent contact angle of large steady evaporating drops with influx. Otherwise they recede right from the beginning

    Rapidity and Centrality Dependence of Proton and Anti-proton Production from Au+Au Collisions at sqrt(sNN) = 130GeV

    Full text link
    We report on the rapidity and centrality dependence of proton and anti-proton transverse mass distributions from Au+Au collisions at sqrt(sNN) = 130GeV as measured by the STAR experiment at RHIC. Our results are from the rapidity and transverse momentum range of |y|<0.5 and 0.35 <p_t<1.00GeV/c. For both protons and anti-protons, transverse mass distributions become more convex from peripheral to central collisions demonstrating characteristics of collective expansion. The measured rapidity distributions and the mean transverse momenta versus rapidity are flat within |y|<0.5. Comparisons of our data with results from model calculations indicate that in order to obtain a consistent picture of the proton(anti-proton) yields and transverse mass distributions the possibility of pre-hadronic collective expansion may have to be taken into account.Comment: 4 pages, 3 figures, 1 table, submitted to PR

    Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at √ s = 8 TeV with the ATLAS detector

    Get PDF
    Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb−1 of √ s = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between Emiss T > 150 GeV and Emiss T > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presente

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Magnetic resonance imaging phantoms for quality-control of myocardial T1 and ECV mapping: specific formulation, long-term stability and variation with heart rate and temperature

    Get PDF
    Background: Magnetic resonance imaging (MRI) phantoms are routinely used for quality assurance in MRI centres; however their long term stability for verification of myocardial T1/ extracellular volume fraction (ECV) mapping has never been investigated. Methods: Nickel-chloride agarose gel phantoms were formulated in a reproducible laboratory procedure to mimic blood and myocardial T1 and T2 values, native and late after Gadolinium administration as used in T1/ECV mapping. The phantoms were imaged weekly with an 11 heart beat MOLLI sequence for T1 and long TR spin-echo sequences for T2, in a carefully controlled reproducible manner for 12 months. Results: There were only small relative changes seen in all the native and post gadolinium T1 values (up to 9.0 % maximal relative change in T1 values) or phantom ECV (up to 8.3 % maximal relative change of ECV, up to 2.2 % maximal absolute change in ECV) during this period. All native and post gadolinium T2 values remained stable over time with <2 % change. Temperature sensitivity testing showed MOLLI T1 values in the long T1 phantoms increasing by 23.9 ms per degree increase and short T1 phantoms increasing by 0.3 ms per degree increase. There was a small absolute increase in ECV of 0.069 % (~0.22 % relative increase in ECV) per degree increase. Variation in heart rate testing showed a 0.13 % absolute increase in ECV (~0.45 % relative increase in ECV) per 10 heart rate increase. Conclusions: These are the first phantoms reported in the literature modeling T1 and T2 values for blood and myocardium specifically for the T1mapping/ECV mapping application, with stability tested rigorously over a 12 month period. This work has significant implications for the utility of such phantoms in improving the accuracy of serial scans for myocardial tissue characterisation by T1 mapping methods and in multicentre work
    corecore