8,899 research outputs found
A state-dependent influence of the type-I bursts on the accretion in 4U 1608--52?
We investigated the possible feedback of type-I burst to the accretion
process during the spectral evolution of the atoll source 4U 1608--52. By
fitting the burst spectrum with a blackbody and an adjustable, persistent
spectral component, we found that the latter is significant state-dependent. In
the banana state the persistent flux increases along the burst evolution, while
in the island state this trend holds only when the bursts are less luminous and
starts to reverse at higher burst luminosities. We speculate that, by taking
into account both the Poynting-Robertson drag and radiation pressure, these
phenomena may arise from the interactions between the radiation field of the
type-I burst and the inner region of the accretion disc.Comment: 10 pages, 5 figures, accepted by ApJ Lette
Possible hard X-ray shortages in bursts from KS 1731-260 and 4U 1705-44
Aims: A hard X-ray shortage, implying the cooling of the corona, was observed
during bursts of IGR J17473-272, 4U 1636-536, Aql X-1, and GS 1826-238. Apart
from these four sources, we investigate here an atoll sample, in which the
number of bursts for each source is larger than 5, to explore the possible
additional hard X-ray shortage during {\it Rossi X-ray timing explorer (RXTE)}
era. Methods: According to the source catalog that shows type-I bursts, we
analyzed all the available pointing observations of these sources carried out
by the {\it RXTE} proportional counter array (PCA). We grouped and combined the
bursts according to their outburst states and searched for the possible hard
X-ray shortage while bursting. Results: We found that the island states of KS
1731-260 and 4U 1705-44 show a hard X-ray shortage at significant levels of 4.5
and 4.7 and a systematic time lag of s and
s with respect to the soft X-rays, respectively. While in their banana branches
and other sources, we did not find any consistent shortage.Comment: 5 pages, 4 figures, accepted by A&A as a research not
The hard X-ray behavior of Aql X-1 during type-I bursts
We report the discovery of an anti-correlation between the soft and the hard
X-ray lightcurves of the X-ray binary Aql X-1 when bursting. This behavior may
indicate that the corona is cooled by the soft X-ray shower fed by the type-I
X-ray bursts, and that this process happens within a few seconds. Stacking the
Aql X-1 lightcurves of type-I bursts, we find a shortage in the 40--50 keV
band, delayed by 4.51.4 s with respect to the soft X-rays. The
photospheric radius expansion (PRE) bursts are different in that neither a
shortage nor an excess shows up in the hard X-ray lightcurve.Comment: accepted by ApJ
Effect of electromagnetic stirring on solidification structure of austenitic stainless steel in horizontal continuous casting
An investigation on the influence of low frequency rotary electromagnetic stirring on solidification structure of austenitic stainless steel in horizontal continuous casting was experimentally conducted and carried out on an industrial trial basis. The results show that application of appropriate electromagnetic stirring parameters can obviously improve the macrostructure of austenitic stainless steel, in which both columnar and equiaxed grains can be greatly refined and shrinkage porosity or cavity zone along centerline can be remarkably decreased due to eliminating intracrystalline and enlarging equiaxed grains zone. The industrial trials verify that the electromagnetic stirring intensity of austenitic stainless steel should be higher than that of plain carbon steel. Electromagnetic stirring has somewhat affected the macrostructure of austenitic stainless steel even if the magnetic flux density of the electromagnetic stirring reaches 90 mT (amplitude reaches 141 mT) in average at frequency f=3-4Hz, which provides a reference for the optimization of design and process parameters when applying the rotary electromagnetic stirrer
Colorectal cancer screening with fecal occult blood test: A 22-year cohort study.
The aim of the present study was to investigate the efficacy of colorectal cancer (CRC) screening with a three-tier fecal occult blood test (FOBT) in the Chinese population. The study was performed between 1987 and 2008 at the Beijing Military General Hospital, in a cohort of army service males and females aged >50 years. Between 1987 and 2005, a three-tier screening program, comprising guaiac-based FOBTs (gFOBTs), followed by immunochemical FOBTs for positive guaiac test samples and then colonoscopy for positive immunochemical test subjects, was performed annually. The cohort was followed up until 2008. The cohort included 5,104 subjects, of which, 3,863 subjects participated in screening (screening group) and 1,241 did not (non-screening group). The two groups did not differ in age, gender or other major risk factors for colon cancer. Overall, 36 CRCs occurred in the screening group and 21 in the non-screening group. Compared with the non-screening group, the relative risk for the incidence and mortality of CRC was 0.51 [95% confidence interval (CI), 0.30-0.87] and 0.36 (95% CI, 0.18-0.71), respectively, in the screening group. The general sensitivity of this three-tier FOBT was 80.6% (95% CI, 65.3-91.1). Thus, annual screening using the three-tier FOBT program may reduce the CRC incidence and mortality rate
Design And Fabrication of Condenser Microphone Using Wafer Transfer And Micro-electroplating Technique
A novel fabrication process, which uses wafer transfer and
micro-electroplating technique, has been proposed and tested. In this paper,
the effects of the diaphragm thickness and stress, the air-gap thickness, and
the area ratio of acoustic holes to backplate on the sensitivity of the
condenser microphone have been demonstrated since the performance of the
microphone depends on these parameters. The microphone diaphragm has been
designed with a diameter and thickness of 1.9 mm and 0.6 m, respectively,
an air-gap thickness of 10 m, and a 24% area ratio of acoustic holes to
backplate. To obtain a lower initial stress, the material used for the
diaphragm is polyimide. The measured sensitivities of the microphone at the
bias voltages of 24 V and 12 V are -45.3 and -50.2 dB/Pa (at 1 kHz),
respectively. The fabricated microphone shows a flat frequency response
extending to 20 kHz.Comment: Submitted on behalf of EDA Publishing Association
(http://irevues.inist.fr/handle/2042/16838
- …
