8,382 research outputs found
Analysis of new high-precision transit light curves of WASP-10 b: starspot occultations, small planetary radius, and high metallicity
The WASP-10 planetary system is intriguing because different values of radius
have been reported for its transiting exoplanet. The host star exhibits
activity in terms of photometric variability, which is caused by the rotational
modulation of the spots. Moreover, a periodic modulation has been discovered in
transit timing of WASP-10 b, which could be a sign of an additional body
perturbing the orbital motion of the transiting planet. We attempt to refine
the physical parameters of the system, in particular the planetary radius,
which is crucial for studying the internal structure of the transiting planet.
We also determine new mid-transit times to confirm or refute observed anomalies
in transit timing. We acquired high-precision light curves for four transits of
WASP-10 b in 2010. Assuming various limb-darkening laws, we generated best-fit
models and redetermined parameters of the system. The prayer-bead method and
Monte Carlo simulations were used to derive error estimates. Three transit
light curves exhibit signatures of the occultations of dark spots by the planet
during its passage across the stellar disk. The influence of stellar activity
on transit depth is taken into account while determining system parameters. The
radius of WASP-10 b is found to be no greater than 1.03 Jupiter radii, a value
significantly smaller than most previous studies indicate. We calculate
interior structure models of the planet, assuming a two-layer structure with
one homogeneous envelope atop a rock core. The high value of the WASP-10 b's
mean density allows one to consider the planet's internal structure including
270 to 450 Earth masses of heavy elements. Our new mid-transit times confirm
that transit timing cannot be explained by a constant period if all literature
data points are considered. They are consistent with the ephemeris assuming a
periodic variation of transit timing...Comment: Accepted for publication in A&
How to ask sensitive questions in conservation: A review of specialized questioning techniques
Tools for social research are critical for developing an understanding of conservation problems and assessing the feasibility of conservation actions. Social surveys are an essential tool frequently applied in conservation to assess both people’s behaviour and to understand its drivers. However, little attention has been given to the weaknesses and strengths of different survey tools. When topics of conservation concern are illegal or otherwise sensitive, data collected using direct questions are likely to be affected by non-response and social desirability biases, reducing their validity. These sources of bias associated with using direct questions on sensitive topics have long been recognised in the social sciences but have been poorly considered in conservation and natural resource management.
We reviewed specialized questioning techniques developed in a number of disciplines specifically for investigating sensitive topics. These methods ensure respondent anonymity, increase willingness to answer, and critically, make it impossible to directly link incriminating data to an individual. We describe each method and report their main characteristics, such as data requirements, possible data outputs, availability of evidence that they can be adapted for use in illiterate communities, and summarize their main advantages and disadvantages. Recommendations for their application in conservation are given. We suggest that the conservation toolbox should be expanded by incorporating specialized questioning techniques, developed specifically to increase response accuracy. By considering the limitations of each survey technique, we will ultimately contribute to more effective evaluations of conservation interventions and more robust policy decisions
Recommended from our members
Characterization of cutaneous and articular sensory neurons
Background: A wide range of stimuli can activate sensory neurons and neurons innervating specific tissues often have distinct properties. Here we used retrograde tracing to identify sensory neurons innervating the hind paw skin (cutaneous) and ankle/knee joints (articular), and combined immunohistochemistry and electrophysiology analysis to determine the neurochemical phenotype of cutaneous and articular neurons, as well as their electrical and chemical excitability.
Results: Immunohistochemistry analysis using RetroBeads as a retrograde tracer confirmed previous data that cutaneous and articular neurons are a mixture of myelinated and unmyelinated neurons, and the majority of both populations are peptidergic. In whole-cell patch-clamp recordings from cultured dorsal root ganglion neurons, voltage-gated inward currents and action potential parameters were largely similar between articular and cutaneous neurons, although cutaneous neuron action potentials had a longer half-peak duration. An assessment of chemical sensitivity showed that all neurons responded to a pH 5.0 solution, but that acid-sensing ion channel (ASIC) currents, determined by inhibition with the non-selective ASIC antagonist benzamil, were of a greater magnitude in cutaneous compared to articular neurons. 40 – 50% of cutaneous and articular neurons responded to capsaicin, cinnamaldehyde and menthol, indicating similar expression levels of TRPV1, TRPA1 and TRPM8 respectively. By contrast, significantly more articular neurons responded to ATP than cutaneous neurons.
Conclusion: This work makes a detailed characterization of cutaneous and articular sensory neurons, and highlights the importance of making recordings from identified neuronal populations: sensory neurons innervating different tissues have subtly different properties, possibly reflecting different functions.ISS was funded by an Erasmus for Graduate Students grant from the University of Coimbra. ZMAH and experiments were funded by an Arthritis Research Project Grant (Grant Reference 20930) to ESS. JDB was funded by a Corpus Christi College Study and Travel Grant. EStJS was funded by an Early Career Research Grant from the International Association for the Study of Pain. Thanks to Christoforos Tsantoulas for assistance with immunohistochemistry and members of the Smith lab for their technical assistance and help in preparing the manuscript.This is the final version of the article. It first appeared from SAGE via http://dx.doi.org/10.1177/174480691663638
Implementation of a Toffoli Gate with Superconducting Circuits
The quantum Toffoli gate allows universal reversible classical computation.
It is also an important primitive in many quantum circuits and quantum error
correction schemes. Here we demonstrate the realization of a Toffoli gate with
three superconducting transmon qubits coupled to a microwave resonator. By
exploiting the third energy level of the transmon qubit, the number of
elementary gates needed for the implementation of the Toffoli gate, as well as
the total gate time can be reduced significantly in comparison to theoretical
proposals using two-level systems only. We characterize the performance of the
gate by full process tomography and Monte Carlo process certification. The gate
fidelity is found to be %.Comment: 4 pages, 5figure
Recommended from our members
Supporting older and younger adults’ memory for recent everyday events: a prospective sampling study using SenseCam
This study measured the effect of a wearable camera, SenseCam, on older and younger adults’ memories of recently experienced everyday events. Participants used SenseCam to prospectively sample events from a typical week, which they recalled two weeks later. Recall was cued by a self-generated title only (control condition), by the title and forward-order SenseCam images, or by the title and random-order SenseCam images. In the control condition, older and younger adults’ memories were comparably episodic, but older adults recalled more semantic details. Both forward- and random-order SenseCam images were associated with increased episodic and semantic recall in both groups, and there was a small but significant effect of temporal order favouring the forward-order condition. These findings suggest that SenseCam is effective in supporting retrieval of memory for recent events, and the results of the temporal order manipulation also shed light on the mechanism of SenseCam’s effect
Results from the First Science Run of the ZEPLIN-III Dark Matter Search Experiment
The ZEPLIN-III experiment in the Palmer Underground Laboratory at Boulby uses
a 12kg two-phase xenon time projection chamber to search for the weakly
interacting massive particles (WIMPs) that may account for the dark matter of
our Galaxy. The detector measures both scintillation and ionisation produced by
radiation interacting in the liquid to differentiate between the nuclear
recoils expected from WIMPs and the electron recoil background signals down to
~10keV nuclear recoil energy. An analysis of 847kg.days of data acquired
between February 27th 2008 and May 20th 2008 has excluded a WIMP-nucleon
elastic scattering spin-independent cross-section above 8.1x10(-8)pb at
55GeV/c2 with a 90% confidence limit. It has also demonstrated that the
two-phase xenon technique is capable of better discrimination between electron
and nuclear recoils at low-energy than previously achieved by other xenon-based
experiments.Comment: 12 pages, 17 figure
Limits on the Majorana neutrino mass in the 0.1 eV range
The Heidelberg-Moscow experiment gives the most stringent limit on the
Majorana neutrino mass. After 24 kg yr of data with pulse shape measurements,
we set a lower limit on the half-life of the neutrinoless double beta decay in
76Ge of T_1/2 > 5.7 * 10^{25} yr at 90% C.L., thus excluding an effective
Majorana neutrino mass greater than 0.2 eV. This allows to set strong
constraints on degenerate neutrino mass models.Comment: 6 pages (latex) including 3 postscript figures and 2 table
An environmentally benign antimicrobial nanoparticle based on a silver-infused lignin core
Silver nanoparticles have antibacterial properties, but their use has been a cause for concern because they persist in the environment. Here, we show that lignin nanoparticles infused with silver ions and coated with a cationic polyelectrolyte layer form a biodegradable and green alternative to silver nanoparticles. The polyelectrolyte layer promotes the adhesion of the particles to bacterial cell membranes and, together with silver ions, can kill a broad spectrum of bacteria, including Escherichia coli, Pseudomonas aeruginosa and quaternary-amine-resistant Ralstonia sp. Ion depletion studies have shown that the bioactivity of these nanoparticles is time-limited because of the desorption of silver ions. High-throughput bioactivity screening did not reveal increased toxicity of the particles when compared to an equivalent mass of metallic silver nanoparticles or silver nitrate solution. Our results demonstrate that the application of green chemistry principles may allow the synthesis of nanoparticles with biodegradable cores that have higher antimicrobial activity and smaller environmental impact than metallic silver nanoparticles
After LUX: The LZ Program
The LZ program consists of two stages of direct dark matter searches using
liquid Xe detectors. The first stage will be a 1.5-3 tonne detector, while the
last stage will be a 20 tonne detector. Both devices will benefit tremendously
from research and development performed for the LUX experiment, a 350 kg liquid
Xe dark matter detector currently operating at the Sanford Underground
Laboratory. In particular, the technology used for cryogenics and electrical
feedthroughs, circulation and purification, low-background materials and
shielding techniques, electronics, calibrations, and automated control and
recovery systems are all directly scalable from LUX to the LZ detectors.
Extensive searches for potential background sources have been performed, with
an emphasis on previously undiscovered background sources that may have a
significant impact on tonne-scale detectors. The LZ detectors will probe
spin-independent interaction cross sections as low as 5E-49 cm2 for 100 GeV
WIMPs, which represents the ultimate limit for dark matter detection with
liquid xenon technology.Comment: Conference proceedings from APS DPF 2011. 9 pages, 6 figure
- …
