1,501 research outputs found
Disparity and optical flow partitioning using extended Potts priors
This paper addresses the problems of disparity and optical flow partitioning based on the brightness invariance assumption. We investigate new variational approaches to these problems with Potts priors and possibly box constraints. For the optical flow partitioning, our model includes vector-valued data and an adapted Potts regularizer. Using the notion of asymptotically level stable (als) functions, we prove the existence of global minimizers of our functionals. We propose a modified alternating direction method of multipliers. This iterative algorithm requires the computation of global minimizers of classical univariate Potts problems which can be done efficiently by dynamic programming. We prove that the algorithm converges both for the constrained and unconstrained problems. Numerical examples demonstrate the very good performance of our partitioning method
Sensitivity of Next-Generation Tritium Beta-Decay Experiments for keV-Scale Sterile Neutrinos
We investigate the sensitivity of tritium -decay experiments for
keV-scale sterile neutrinos. Relic sterile neutrinos in the keV mass range can
contribute both to the cold and warm dark matter content of the universe. This
work shows that a large-scale tritium beta-decay experiment, similar to the
KATRIN experiment that is under construction, can reach a statistical
sensitivity of the active-sterile neutrino mixing of . The effect of uncertainties in the known theoretical corrections to
the tritium -decay spectrum were investigated, and found not to affect
the sensitivity significantly. It is demonstrated that controlling uncorrelated
systematic effects will be one of the main challenges in such an experiment.Comment: 24 pages, 16 figure
Определение эффективности нейтронного детектора из пластического сцинтиллятора o100?200 мм
Рассчитывается и экспериментально проверяется эффективность детектора. к нейтронам сверхвысоких (десятки и сотни МэВ) энергий
Improved limits on nuebar emission from mu+ decay
We investigated mu+ decays at rest produced at the ISIS beam stop target.
Lepton flavor (LF) conservation has been tested by searching for \nueb via the
detection reaction p(\nueb,e+)n. No \nueb signal from LF violating mu+ decays
was identified. We extract upper limits of the branching ratio for the LF
violating decay mu+ -> e+ \nueb \nu compared to the Standard Model (SM) mu+ ->
e+ nue numub decay: BR < 0.9(1.7)x10^{-3} (90%CL) depending on the spectral
distribution of \nueb characterized by the Michel parameter rho=0.75 (0.0).
These results improve earlier limits by one order of magnitude and restrict
extensions of the SM in which \nueb emission from mu+ decay is allowed with
considerable strength. The decay \mupdeb as source for the \nueb signal
observed in the LSND experiment can be excluded.Comment: 10 pages, including 1 figure, 1 tabl
Dead layer on silicon p-i-n diode charged-particle detectors
Semiconductor detectors in general have a dead layer at their surfaces that
is either a result of natural or induced passivation, or is formed during the
process of making a contact. Charged particles passing through this region
produce ionization that is incompletely collected and recorded, which leads to
departures from the ideal in both energy deposition and resolution. The silicon
\textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a
dead layer. We have constructed a detailed Monte Carlo model for the passage of
electrons from vacuum into a silicon detector, and compared the measured energy
spectra to the predicted ones for a range of energies from 12 to 20 keV. The
comparison provides experimental evidence that a substantial fraction of the
ionization produced in the "dead" layer evidently escapes by diffusion, with
46% being collected in the depletion zone and the balance being neutralized at
the contact or by bulk recombination. The most elementary model of a thinner
dead layer from which no charge is collected is strongly disfavored.Comment: Manuscript submitted to NIM
Commissioning of the vacuum system of the KATRIN Main Spectrometer
The KATRIN experiment will probe the neutrino mass by measuring the
beta-electron energy spectrum near the endpoint of tritium beta-decay. An
integral energy analysis will be performed by an electro-static spectrometer
(Main Spectrometer), an ultra-high vacuum vessel with a length of 23.2 m, a
volume of 1240 m^3, and a complex inner electrode system with about 120000
individual parts. The strong magnetic field that guides the beta-electrons is
provided by super-conducting solenoids at both ends of the spectrometer. Its
influence on turbo-molecular pumps and vacuum gauges had to be considered. A
system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter
strips has been deployed and was tested during the commissioning of the
spectrometer. In this paper the configuration, the commissioning with bake-out
at 300{\deg}C, and the performance of this system are presented in detail. The
vacuum system has to maintain a pressure in the 10^{-11} mbar range. It is
demonstrated that the performance of the system is already close to these
stringent functional requirements for the KATRIN experiment, which will start
at the end of 2016.Comment: submitted for publication in JINST, 39 pages, 15 figure
The KATRIN Pre-Spectrometer at reduced Filter Energy
The KArlsruhe TRItium Neutrino experiment, KATRIN, will determine the mass of
the electron neutrino with a sensitivity of 0.2 eV (90% C.L.) via a measurement
of the beta-spectrum of gaseous tritium near its endpoint of E_0 =18.57 keV. An
ultra-low background of about b = 10 mHz is among the requirements to reach
this sensitivity. In the KATRIN main beam-line two spectrometers of MAC-E
filter type are used in a tandem configuration. This setup, however, produces a
Penning trap which could lead to increased background. We have performed test
measurements showing that the filter energy of the pre-spectrometer can be
reduced by several keV in order to diminish this trap. These measurements were
analyzed with the help of a complex computer simulation, modeling multiple
electron reflections both from the detector and the photoelectric electron
source used in our test setup.Comment: 22 pages, 12 figure
Statistical Analysis of Different Muon-antineutrino->Electron-antineutrino Searches
A combined statistical analysis of the experimental results of the LSND and
KARMEN \numubnueb oscillation search is presented. LSND has evidence for
neutrino oscillations that is not confirmed by the KARMEN experiment. This
joint analysis is based on the final likelihood results for both data sets. A
frequentist approach is applied to deduce confidence regions. At a combined
confidence level of 36%, there is no area of oscillation parameters compatible
with both experiments. For the complementary confidence of 1-0.36=64%, there
are two well defined regions of oscillation parameters (sin^2(2th),Dm^2)
compatible with both experiments.Comment: 25 pages, including 10 figures, submitted to Phys. Rev.
- …
