431 research outputs found
Basic performance of a multilayer insulation system containing 20 to 160 layers
An experimental investigation was conducted to determine the thermal effectiveness of an aluminized Mylar-silk net insulation system containing up to 160 layers. The experimentally measured heat flux was compared with results predicted by using (1) a previously developed semi-empirical equation and (2) an effective-thermal-conductivity value. All tests were conducted at a nominal hot-boundary temperature of 294 K (530 R) with liquid hydrogen as the heat sink. The experimental results show that the insulation performed as expected and that both the semi-empirical equation and effective thermal conductivity of a small number of layers were adequate in predicting the thermal performance of a large number of layers of insulation
Assessment of steam-injected gas turbine systems and their potential application
Results were arrived at by utilizing and expanding on information presented in the literature. The results were analyzed and compared with those for simple gas turbine and combined cycles for both utility power generation and industrial cogeneration applications. The efficiency and specific power of simple gas turbine cycles can be increased as much as 30 and 50 percent, respectively, by the injection of steam into the combustor. Steam-injected gas turbines appear to be economically competitive with both simple gas turbine and combined cycles for small, clean-fuel-fired utility power generation and industrial cogeneration applications. For large powerplants with integrated coal gasifiers, the economic advantages appear to be marginal
Thermal performance of a liquid hydrogen tank multilayer insulation system at warm boundary temperatures of 630, 530, and 152 R
The results are presented of a study conducted to obtain experimental heat transfer data on a liquid hydrogen tank insulated with 34 layers of MLI (multilayer insulation) for warm side boundary temperatures of 630, 530, and 150 R. The MLI system consisted of two blankets, each blanket made up of alternate layers of double silk net (16 layers) and double aluminized Mylar radiation shields (15 layers) contained between two cover sheets of Dacron scrim reinforced Mylar. The insulation system was designed for and installed on a 87.6 in diameter liquid hydrogen tank. Nominal layer density of the insulation blankets is 45 layers/in. The insulation system contained penetrations for structural support, plumbing, and electrical wiring that would be representative of a cryogenic spacecraft. The total steady state heat transfer rates into the test tank for shroud temperatures of 630, 530, 152 R were 164.4, 95.8, and 15.9 BTU/hr respectively. The noninsulation heat leaks into the tank (12 fiberglass support struts, tank plumbing, and instrumentation lines) represent between 13 to 17 pct. of the total heat input. The heat input values would translate to liquid H2 losses of 2.3, 1.3, and 0.2 pct/day, with the tank held at atmospheric pressure
Analytic and experimental evaluation of shadow shields and their support members for thermal control of space vehicles
The thermal performance of shadow shields, and their support struts, for the thermal protection of cryogenic propellants in a simulated deep-space environment was investigated analytically and experimentally. Very low overall heat-transfer rates were obtained when highly reflective aluminized Mylar shadow shields were used. The thermal interactions between the shields and support struts were investigated with fair to good agreement between the analysis and experimental data. The exterior surface of both fiberglass and titanium struts was coated to reduce the heat input into the test tank. The vacuum level inside the test facility strongly influenced the heat-transfer rates
Off-design analysis of a gas turbine powerplant augmented by steam injection using various fuels
Results are compared using coal derived low and intermediate heating valve fuel gases and a conventional distillate. The results indicate that steam injection provides substantial increases in both power and efficiency within the available compressor surge margin. The results also indicate that these performance gains are relatively insensitive as to the type of fuel. Also, in a cogeneration application, steam injection could provide some degree of flexibility by varying the split between power and process steam
Potential performance improvement using a reacting gas (nitrogin tetroxide) as the working fluid in a closed Brayton cycle
The results of an analysis to estimate the performance that could be obtained by using a chemically reacting gas (nitrogen tetroxide) as the working fluid in a closed Brayton cycle are presented. Compared with data for helium as the working fluid, these results indicate efficiency improvements from 4 to 90 percent, depending on turbine inlet temperature, pressures, and gas residence time in heat transfer equipment
Mokken scaling analysis of Revised Clinical Interview Schedule (CIS-R) psychiatric status rating scales in a nationally representative sample:the 2007 Adult Psychiatric Morbidity Survey of England
Accurate, rapid, temperature and liquid-level sensor for cryogenic tanks
Thermopiles measure ullage gas temperatures to within plus or minus 1.65 deg K between 20 and 300 deg K, and also serve as point liquid-level sensors. Thermopile technique measures smaller temperature differences by keeping the reference junctions inside the tank and near the temperature range of the measuring junction
Autogenous pressurization of cryogenic vessels using submerged vapor injection
Experimental results are reported for submerged injection pressurization and expulsion tests of a 4.89 cu m liquid hydrogen tank. The pressurant injector was positioned near the bottom of the test vessel to simulate liquid engulfment of the pressurant gas inlet; a condition that may occur in low-gravity conditions. Results indicate a substantial reduction in pressurization efficiency, with pressurant gas requirements approximately five times greater than ideal amounts. Consequently, submerged vapor injection should be avoided as a low-gravity autogenous pressurization method whenever possible. The work presented herein validates that pressurent requirements are accurately predicted by a homogeneous thermodynamic model when the submerged injection technique is employed
Pressurization and expulsion of cryogenic liquids: Generic requirements for a low gravity experiment
Requirements are presented for an experiment designed to obtain data for the pressurization and expulsion of a cryogenic supply tank in a low gravity environment. These requirements are of a generic nature and applicable to any cryogenic fluid of interest, condensible or non-condensible pressurants, and various low gravity test platforms such as the Space Shuttle or a free-flyer. Background information, the thermophysical process, preliminary analytical modeling, and experimental requirements are discussed. Key parameters, measurements, hardware requirements, procedures, a test matrix, and data analysis are outlined
- …