13,000 research outputs found
Watkins\u27 Patent trolls: Predatory litigation and the smothering of innovation (Book Review)
A review of Watkins, W. J., Jr. (2013). Patent trolls: Predatory litigation and the smothering of innovation. Oakland, CA: The Independent Institute. 96 pp. $17.95. ISBN 978159813170
The Vlasov-Poisson-Landau System in
For the Landau-Poisson system with Coulomb interaction in , we prove
the global existence, uniqueness, and large time convergence rates to the
Maxwellian equilibrium for solutions which start out sufficiently close.Comment: 50 page
Transient evoked otoacoustic emissions testing for screening of sensorineural deafness in puppies
<p><b>Background:</b> Transient evoked otoacoustic emissions (TEOAE) are widely used for human neonatal deafness screening, but have not been reported for clinical use in dogs.</p>
<p><b>Hypothesis/Objectives:</b> To investigate the feasibility of TEOAE testing in conscious puppies and the ability of TEOAE testing to correctly identify deaf and hearing ears, as defined by brainstem auditory evoked response (BAER).</p>
<p><b>Animals:</b> Forty puppies from 10 litters.</p>
<p><b>Methods:</b> Prospective study on puppies presented for hearing assessment as part of a congenital deafness BAER screening program. Hearing status was determined using BAER. TEOAE testing was performed after the BAER assessment and the results of the TEOAE testing were compared with the hearing status for each ear. Parameters were tested for normality using the D'Agostino Pearson test and comparisons between the deaf and hearing ears were made using Mann-Whitney tests.</p>
<p><b>Results:</b> TEOAE testing was readily performed in puppies presented for congenital deafness screening. Using analysis parameters based on those used in human neonatal hearing screening, TEOAE testing correctly identified all deaf ears, as defined by BAER testing, with a sensitivity of 100% (95% CI: 56-100%) for diagnosing deafness and specificity of 78% (95% CI: 66-87%).</p>
<p><b>Conclusions and Clinical Importance:</b> TEOAE testing is an effective screening modality for identifying congenital sensorineural deafness in dogs. In light of the simpler and less expensive equipment, TEOAE testing has the potential to improve access to hearing screening and through this reduce the prevalence of congenital deafness in the dog.</p>
DSS-14 subreflector actuator dynamics during the Landers earthquake
The 28 Jun. 1992 Landers earthquake ground motion records at the Echo site (DSS-12 antenna) were adjusted to provide a better match with spectra from the measured Mars site (DSS-14 antenna) instrument tower response. A finite-element model of the antenna structural system was analyzed for response to this ground motion. Dynamic forces and displacements were computed in the locality of components that had failed during the earthquake. Calculated forces in the range of 30,000 to 35,000 lb on failed Y-axis actuator U-joints were consistent with laboratory load tests. The load capacity of these joints was found to be below the range of 34,000 to 42,000 lb. Dynamic amplification factors of from 6 to 16 were computed for the quadripod apex accelerations with respect to the ground accelerations. The largest factor--25--was found at the outboard end of the X-actuator
Axisymmetric flow of ideal fluid moving in a narrow domain: a study of the axisymmetric hydrostatic Euler equations
In this article we will introduce a new model to describe the leading order
behavior of an ideal and axisymmetric fluid moving in a very narrow domain.
After providing a formal derivation of the model, we will prove the
well-posedness and provide a rigorous mathematical justification for the formal
derivation under a new sign condition. Finally, a blowup result regarding this
model will be discussed as well.Comment: 33 page
Ultrashort Q-switched pulses from a passively mode-locked distributed Bragg reflector semiconductor laser
A compact semiconductor mode-locked laser (MLL) is presented that demonstrates strong passive Q-switched mode-locking over a wide range of drive conditions. The Q-switched frequency is tunable between 1 and 4 GHz for mode-locked pulses widths around 3.5 ps. The maximum ratio of peak to average power of the pulse-train is >120, greatly exceeding that of similarly sized passively MLLs
- …
