172 research outputs found
Food-Based dietary guidelines around the World: Eastern Mediterranean and Middle Eastern Countries
In Eastern Mediterranean countries, undernutrition and micronutrient deficiencies coexist with overnutrition-related diseases, such as obesity, heart disease, diabetes and cancer. Many Mediterranean countries have produced Food-Based Dietary Guidelines (FBDGs) to provide the general population with indications for healthy nutrition and lifestyles. This narrative review analyses Eastern Mediterranean countries' FBDGs and discusses their pictorial representations, food groupings and associated messages on healthy eating and behaviours. In 2012, both the WHO and the Arab Center for Nutrition developed specific dietary guidelines for Arab countries. In addition, seven countries, representing 29% of the Eastern Mediterranean Region population, designated their national FBDGs. At the moment several of these guidelines are available only in the English language. In summary, Eastern Mediterranean FBDGs mainly focus on food safety, not all are available in the local Arabic language, and they do not provide specific suggestions for the large number of foreign workers and migrants
Balanced Propofol Sedation in Patients Undergoing EUS-FNA: A Pilot Study to Assess Feasibility and Safety
Introduction and aims. Balanced propofol sedation (BPS) administered by gastroenterologists has gained popularity in endoscopic procedures. Few studies exist about the safety of this approach during endosonography with fine needle aspiration (EUS-FNA). We assessed the safety of BPS in EUS-FNA. Materials and methods. 112 consecutive patients, referred to our unit to perform EUS-FNA, from February 2008 to December 2009, were sedated with BPS. A second gastroenterologist administered the drugs and monitorized the patient. Results. All the 112 patients (62 males, mean age 58.35) completed the examination. The mean dose of midazolam and propofol was, respectively, of 2.1 mg (range 1–4 mg) and 350 mg (range 180–400). All patients received oxygen with a mean flux of 4 liter/minute (range 2–6 liters/minute). The mean recovery time after procedure was 25 minutes (range 18–45 minutes). No major complications related to sedation were registered during all procedures. The oxygen saturation of all patients never reduced to less than 85%. Blood systolic pressure during and after the procedure never reduced to less than 100 mmHg. Conclusions. In our experience BPS administered by non-anaesthesiologists provided safe and successful sedation in patients undergoing EUS-FNA
Microscopic origin of random telegraph noise fluctuations in aggressively scaled RRAM and its impact on read disturb variability
Random telegraph noise (RTN) is an important intrinsic phenomenon of any logic or memory device that is indicative of the reliability and stochastic variability in its performance. In the context of the resistive random access memory (RRAM), RTN becomes a key criterion that determines the read disturb immunity and memory window between the low (LRS) and high resistance states (HRS). With the drive towards ultra-low power memory (low reset current) and aggressive scaling to 10 × 10 nm2 area, contribution of RTN is significantly enhanced by every trap (vacancy) in the dielectric. The underlying mechanisms governing RTN in RRAM are yet to be fully understood. In this study, we aim to decode the role of conductance fluctuations caused by oxygen vacancy transport and inelastic electron trapping and detrapping processes. The influence of resistance state (LRS, shallow and deep HRS), reset depth and reset stop voltage (VRESET-STOP) on the conductance variability is also investigated. © 2013 IEEE
Strained Silicon Complementary TFET SRAM: Experimental Demonstration and Simulations
A half SRAM cell with strained Si nanowire complementary tunnel-FETs (TFETs) was fabricated and characterized to explore the feasibility and functionality of 6T-SRAM based on TFETs. Outward-faced n-TFETs are used as access-transistors. Static measurements were performed to determine the SRAM butterfly curves, allowing the assessment of cell functionality and stability. The forward p-i-n leakage of the access-transistor at certain bias configurations leads to malfunctioning storage operation, even without the contribution of the ambipolar behavior. At large VDD, lowering of the bit-line bias is needed to mitigate such effect, demonstrating functional hold, read and write operations. Circuit simulations were carried out using a Verilog-A compact model calibrated on the experimental TFETs, providing a better understanding of the TFET SRAM operation at different supply voltages and for different cell sizing and giving an estimate of the dynamic performance of the cell
Changes of intracardiac flow dynamics measured by HyperDoppler in patients with aortic stenosis
Aims Assessment of intracardiac flow dynamics has recently acquired significance due to the development of new measurement methods based on echocardiography. Recent studies have demonstrated that cardiac abnormalities are associated with changes in intracardiac vortical flows. Yet, no previous study assessed the impact of aortic stenosis (AS) on intracardiac vortices. This study aims to explore the clinical potential of additional information provided by quantifying intracardiac flow dynamics in patients with AS. Methods and results One hundred and twenty patients with severe AS, sixty patients with concentric ventricular remodelling (VR), and hundred controls (CTRL) were prospectively included and underwent non-invasive evaluation of intracardiac flow dynamics. In addition to standard echocardiography, fluid dynamics were assessed by means of HyperDoppler. Vortex depth (P < 0.001), vortex length (P = 0.003), vortex intensity (P < 0.001), and vortex area (P = 0.049) were significantly increased in AS compared with CTRL. In addition, mean energy dissipation was significantly higher in AS compared with CTRL (P < 0.001) and VR (P = 0.002). At receiver operating characteristic analysis, vortex depth showed the best discrimination capacity for AS (P < 0.001). Conclusion Changes in fluid dynamics-based HyperDoppler indices can be reliably assessed in patients with AS. Significant changes in vortex depth and intensity can selectively differentiate AS from both concentric remodelling and healthy CTRLs, suggesting that the assessment of intracardiac flow dynamics may provide complementary information to standard echocardiography to better characterize patients' subsets
GOLFIG Chemo-Immunotherapy in Metastatic Colorectal Cancer Patients. A Critical Review on a Long-Lasting Follow-Up
Background: GOLFIG is a chemo-immunotherapy regimen established in preclinical models that combines gemcitabine + FOLFOX (fluoropyrimidine backbone coupled to oxaliplatin) poly-chemotherapy with low-dose s. c. recombinant interleukin-2 (rIL-2) and granulocyte-macrophage colony stimulating factor (GM-CSF). Promising antitumor effects in metastatic colorectal cancer (mCRC) patients were obtained in previous phase II and III trials. Here we report the results of 15 years of follow-up. Methods: This is a multi-institutional retrospective analysis including 179 mCRC patients receiving GOLFIG regimen between June 2002 and June 2018. Sixty-two of them received the treatment as frontline (enrolled in the GOLFIG-2 phase III trial) and 117 as second/third line (49 enrolled in the GOLFIG-1 phase II trial and 68 as compassionate use). One hundred twelve patients showed a primary left side and 67 a primary right side; K/N-ras mutational status was available in 74 cases, and an activating mutation was detected in 33. Kaplan–Meier and Cox regression analyses were carried out to relate PFS and OS with different parameters. Results: Overall, we recorded a mean PFS and OS of 15.28 (95% CI: 10.36–20.20) and 24.6 (95% CI: 19.07–30.14) months, respectively, with 14 patients surviving free of progression for 10 years. This regimen, in our updated survey of the GOLFIG-2 trial, confirmed superiority over FOLFOX in terms of PFS (hazard ratio (HR) = 0.58, p = 0.006) with a trend to a longer OS (HR = 0.69, P = 0.06) in the first line. Our analysis also confirmed significant antitumor activity in pre-treated patients, reporting a mean PFS and OS of 12.55 (95% CI: 7.19–17.9) and 20.28 (95% CI: 14.4–26.13) months, respectively. Immune-related adverse events (irAEs) were recorded in 24% of the cases and were related to a longer survival (HR = 0.36; P = 0.0001). Finally, patients' outcome was not correlated to sex, sidedness, and MT-K/N-ras. Conclusions: The GOLFIG regimen is a reliable underestimated therapeutic option in pre-treated mCRC patients and offers a strong rationale to design further trials
Hind limb unloading of mice modulates gene expression at the protein and mRNA level in mesenchymal bone cells
Organization and Activity of Italian Echocardiographic Laboratories: A Survey of the Italian Society of Echocardiography and Cardiovascular Imaging
Background: The Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand better how different echocardiographic modalities are used and accessed in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved via an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories: 112 centers (49%) in the northern, 43 centers (19%) in the central, and 73 (32%) in the southern regions. During the month of observation, we collected 101,050 transthoracic echocardiography (TTE) examinations performed in all centers. As concern other modalities there were performed 5497 transesophageal echocardiography (TEE) examinations in 161/228 centers (71%); 4057 stress echocardiography (SE) examinations in 179/228 centers (79%); and examinations with ultrasound contrast agents (UCAs) in 151/228 centers (66%). We did not find significant regional variations between the different modalities. The usage of picture archiving and communication system (PACS) was significantly higher in the northern (84%) versus central (49%) and southern (45%) centers (P < 0.001). Lung ultrasound (LUS) was performed in 154 centers (66%), without difference between cardiology and noncardiology centers. The evaluation of left ventricular (LV) ejection fraction was evaluated mainly using the qualitative method in 223 centers (94%), occasionally with the Simpson method in 193 centers (85%), and with selective use of the three-dimensional (3D) method in only 23 centers (10%). 3D TTE was present in 137 centers (70%), and 3D TEE in all centers where TEE was done (71%). The assessment of LV diastolic function was done routinely in 80% of the centers. Right ventricular function was evaluated using tricuspid annular plane systolic excursion in all centers, using tricuspid valve annular systolic velocity by tissue Doppler imaging in 53% of the centers, and using fractional area change in 33% of the centers. When we divided into cardiology (179, 78%) and noncardiology (49, 22%) centers, we found significant differences in the SE (93% vs. 26%, P < 0.001), TEE (85% vs. 18%), UCA (67% vs. 43%, P < 0001), and STE (87% vs. 20%, P < 0.001). The incidence of LUS evaluation was similar between the cardiology and noncardiology centers (69% vs. 61%, P = NS). Conclusions: This nationwide survey demonstrated that digital infrastructures and advanced echocardiography modalities, such as 3D and STE, are widely available in Italy with a notable diffuse uptake of LUS in the core TTE examination, a suboptimal diffusion of PACS recording, and conservative use of UCA, 3D, and strain. There are significant differences between northern and central-southern regions and echocardiographic laboratories that pertain to the cardiac unit. This inhomogeneous distribution of technology represents one of the main issues that must be solved to standardize the practice of echocardiography
Stress echocardiography in Italian echocardiographic laboratories: A survey of the Italian society of echocardiography and cardiovascular imaging
Background: The Italian Society of Echography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand the volumes of activity, modalities and stressors used during stress echocardiography (SE) in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved through an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories, and SE examinations were performed in 179 centers (80.6%): 87 centers (47.5%) were in the northern regions of Italy, 33 centers (18.4%) were in the central regions, and 61 (34.1%) in the southern regions. We annotated a total of 4057 SE. We divided the SE centers into three groups, according to the numbers of SE performed: <10 SE (low-volume activity, 40 centers), between 10 and 39 SE (moderate volume activity, 102 centers) and >= 40 SE (high volume activity, 37 centers). Dipyridamole was used in 139 centers (77.6%); exercise in 120 centers (67.0%); dobutamine in 153 centers (85.4%); pacing in 37 centers (21.1%); and adenosine in 7 centers (4.0%). We found a significant difference between the stressors used and volume of activity of the centers, with a progressive increase in the prevalence of number of stressors from low to high volume activity (P = 0.033). The traditional evaluation of regional wall motion of the left ventricle was performed in all centers, with combined assessment of coronary flow velocity reserve (CFVR) in 90 centers (50.3%): there was a significant difference in the centers with different volume of SE activity: the incidence of analysis of CFVR was significantly higher in high volume centers compared to low - moderate - volume (32.5%, 41.0% and 73.0%, respectively, P < 0.001). The lung ultrasound (LUS) was assessed in 67 centers (37.4%). Furthermore for LUS, we found a significant difference in the centers with different volume of SE activity: significantly higher in high volume centers compared to low - moderate - volume (25.0%, 35.3% and 56.8%, respectively, P < 0.001). Conclusions: This nationwide survey demonstrated that SE was significantly widespread and practiced throughout Italy. In addition to the traditional indication to coronary artery disease based on regional wall motion analysis, other indications are emerging with an increase in the use of LUS and CFVR, especially in high-volume centers
- …
