8 research outputs found

    Measuring organisational readiness for patient engagement (MORE) : an international online Delphi consensus study

    Get PDF
    Date of Acceptance: 28/01/2015. © 2015 Oostendorp et al.; licensee BioMed Central. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise statedWidespread implementation of patient engagement by organisations and clinical teams is not a reality yet. The aim of this study is to develop a measure of organisational readiness for patient engagement designed to monitor and facilitate a healthcare organisation’s willingness and ability to effectively implement patient engagement in healthcarePeer reviewedFinal Published versio

    A critical analysis of the cycles of physical activity policy in England

    Get PDF
    BACKGROUND: There has been increasing focus on the importance of national policy to address population levels of physical inactivity. Components of a comprehensive national physical activity policy framework include: 1) national recommendations on physical activity levels; 2) setting population goals and targets; 3) surveillance or health monitoring systems; and 4) public education. The aim of the current paper was to analyse the policy actions which have addressed each of these elements in England and to identify areas of progress and remaining challenges.  METHODS: A literature search was undertaken to identify past and present documents relevant to physical activity policy in England. Each document was analysed to identify content relevant to the four key elements of policy which formed the focus of the current research.  RESULTS: Physical activity recommendations are an area where England has demonstrated a robust scientific approach and good practice; however, the physical activity campaigns in England have not been sufficiently sustained to achieve changes in social norms and behaviour. The setting of physical activity targets has been unrealistic and continuous changes to national surveillance measures have presented challenges for monitoring trends over time.  CONCLUSIONS: Overall, physical activity policy in England has fluctuated over the past two decades. The variations and cycles in policy reflect some of the challenges in implementing and sustaining physical activity policy in the face of political changes, changes in government direction, and changing opportunities to profile active lifestyles

    An observational study to assess if automated diabetic retinopathy image assessment software can replace one or more steps of manual imaging grading and to determine their cost-effectiveness.

    Get PDF
    BACKGROUND: Diabetic retinopathy screening in England involves labour-intensive manual grading of retinal images. Automated retinal image analysis systems (ARIASs) may offer an alternative to manual grading. OBJECTIVES: To determine the screening performance and cost-effectiveness of ARIASs to replace level 1 human graders or pre-screen with ARIASs in the NHS diabetic eye screening programme (DESP). To examine technical issues associated with implementation. DESIGN: Observational retrospective measurement comparison study with a real-time evaluation of technical issues and a decision-analytic model to evaluate cost-effectiveness. SETTING: A NHS DESP. PARTICIPANTS: Consecutive diabetic patients who attended a routine annual NHS DESP visit. INTERVENTIONS: Retinal images were manually graded and processed by three ARIASs: iGradingM (version 1.1; originally Medalytix Group Ltd, Manchester, UK, but purchased by Digital Healthcare, Cambridge, UK, at the initiation of the study, purchased in turn by EMIS Health, Leeds, UK, after conclusion of the study), Retmarker (version 0.8.2, Retmarker Ltd, Coimbra, Portugal) and EyeArt (Eyenuk Inc., Woodland Hills, CA, USA). The final manual grade was used as the reference standard. Arbitration on a subset of discrepancies between manual grading and the use of an ARIAS by a reading centre masked to all grading was used to create a reference standard manual grade modified by arbitration. MAIN OUTCOME MEASURES: Screening performance (sensitivity, specificity, false-positive rate and likelihood ratios) and diagnostic accuracy [95% confidence intervals (CIs)] of ARIASs. A secondary analysis explored the influence of camera type and patients' ethnicity, age and sex on screening performance. Economic analysis estimated the cost per appropriate screening outcome identified. RESULTS: A total of 20,258 patients with 102,856 images were entered into the study. The sensitivity point estimates of the ARIASs were as follows: EyeArt 94.7% (95% CI 94.2% to 95.2%) for any retinopathy, 93.8% (95% CI 92.9% to 94.6%) for referable retinopathy and 99.6% (95% CI 97.0% to 99.9%) for proliferative retinopathy; and Retmarker 73.0% (95% CI 72.0% to 74.0%) for any retinopathy, 85.0% (95% CI 83.6% to 86.2%) for referable retinopathy and 97.9% (95% CI 94.9 to 99.1%) for proliferative retinopathy. iGradingM classified all images as either 'disease' or 'ungradable', limiting further iGradingM analysis. The sensitivity and false-positive rates for EyeArt were not affected by ethnicity, sex or camera type but sensitivity declined marginally with increasing patient age. The screening performance of Retmarker appeared to vary with patient's age, ethnicity and camera type. Both EyeArt and Retmarker were cost saving relative to manual grading either as a replacement for level 1 human grading or used prior to level 1 human grading, although the latter was less cost-effective. A threshold analysis testing the highest ARIAS cost per patient before which ARIASs became more expensive per appropriate outcome than human grading, when used to replace level 1 grader, was Retmarker £3.82 and EyeArt £2.71 per patient. LIMITATIONS: The non-randomised study design limited the health economic analysis but the same retinal images were processed by all ARIASs in this measurement comparison study. CONCLUSIONS: Retmarker and EyeArt achieved acceptable sensitivity for referable retinopathy and false-positive rates (compared with human graders as reference standard) and appear to be cost-effective alternatives to a purely manual grading approach. Future work is required to develop technical specifications to optimise deployment and address potential governance issues. FUNDING: The National Institute for Health Research (NIHR) Health Technology Assessment programme, a Fight for Sight Grant (Hirsch grant award) and the Department of Health's NIHR Biomedical Research Centre for Ophthalmology at Moorfields Eye Hospital and the University College London Institute of Ophthalmology

    A review of prison health and its implications for primary care nursing in England and Wales: The research evidence

    No full text
    Aims and objectives. To provide a systematic overview of the policy and practice literature concerned with the primary healthcare needs of prisoners in England and Wales and to address the implications of these health needs for nurses working in prisons. Background. The recent reorganization of the prison healthcare system, which has brought prison health services in England and Wales within the National Health Service, has major implications for the role of prison nurses. Nurses in prisons are increasingly providing services to promote the health of prisoners, in addition to making assessments of health need and treating health problems. Methods. The review examined literature from 1995 to date using standard review techniques adapted to be both sensitive and inclusive and with high recall because of the unexplored nature of primary health care in prisons. Results. Findings are identified in three main areas: the general health needs of prisoners, health promotion and chronic disease management. In all these areas, the health needs of the prison population are much greater than the community as a whole, resulting in a high demand for primary care services in prison. However, the prison setting can militate against providing good primary care services in prison. Conclusions. More research has been carried out into the health needs of prisoners than into the provision of primary care nursing services in prisons. Further research is needed into primary care nursing in prison to meet the health needs of prisoners effectively. Relevance to Clinical Practice. With the reorganization of prison health services, health provision in prisons is increasingly primary care focused. This presents new challenges to nurses working in prison to provide a primary care service, which meets the identified health needs of prisoners. © 2007 Blackwell Publishing Ltd

    Immunosuppressive therapy for kidney transplantation in adults: a systematic review and economic model.

    Get PDF
    End-stage renal disease is a long-term irreversible decline in kidney function requiring renal replacement therapy: kidney transplantation, haemodialysis or peritoneal dialysis. The preferred option is kidney transplantation, followed by immunosuppressive therapy (induction and maintenance therapy) to reduce the risk of kidney rejection and prolong graft survival.This article is freely available. Click on the 'Additional Link' above to access the full-text
    corecore