705 research outputs found
Electrets used in measuring rocket exhaust effluents from the space shuttle's solid rocket booster during static test firing, DM-3
The purpose of this experimental research was to compare Marshall Space Flight Center's electrets with Thiokol's fixed flow air samplers during the Space Shuttle Solid Rocket Booster Demonstration Model-3 static test firing on October 19, 1978. The measurement of rocket exhaust effluents by Thiokol's samplers and MSFC's electrets indicated that the firing of the Solid Rocket Booster had no significant effect on the quality of the air sampled. The highest measurement by Thiokol's samplers was obtained at Plant 3 (site 11) approximately 8 km at a 113 degree heading from the static test stand. At sites 11, 12, and 5, Thiokol's fixed flow air samplers measured 0.0048, 0.00016, and 0.00012 mg/m3 of CI. Alongside the fixed flow measurements, the electret counts from X-ray spectroscopy were 685, 894, and 719 counts. After background corrections, the counts were 334, 543, and 368, or an average of 415 counts. An additional electred, E20, which was the only measurement device at a site approximately 20 km northeast from the test site where no power was available, obtained 901 counts. After background correction, the count was 550. Again this data indicate there was no measurement of significant rocket exhaust effluents at the test site
Electrets used to measure exhaust cloud effluents from Solid Rocket Motor (SRM) during demonstration model (DM-2) static test firing
Electrets were compared with fixed flow samplers during static test firing. The measurement of the rocket exhaust effluents by samplers and electrets indicated that the Solid Rocket Motor had no significant effect on the air quality in the area sampled. The results show that the electrets (a passive device which needs no power) can be used effectively alongside existing measuring devices (which need power). By placing electrets in areas where no power is available, measurements may be obtained. Consequently, it is a valuable complementary instrument in measuring rocket exhaust effluents in areas where other measuring devices may not be able to assess the contaminants
Experimental research in the use of electrets in measuring effluents from rocket exhaust and a review of standard air quality measuring devices
Seven standard types of measuring devices used to obtain the chemical composition of rocket exhaust effluents were discussed. The electrets, a new measuring device, are investigated and compared with established measuring techniques. The preliminary results obtained show that electrets have multipollutant measuring capabilities, simplicity of deployment, speed of assessment or analysis, and may be an important and valuable tool in measuring pollutants from space vehicle rocket exhaust
Ground-based measurements of DM-2 rocket exhaust effluents using fixed-flow samplers and electrets
Electret devices were used to collect samples of rocket exhaust products. The samples were analyzed by X-ray spectroscopy. The performance of the electrets was compared with that of Thiokol fixed flow samplers during the static test firing of a solid rocket motor (SRM) demonstration model. A vertical profile of wind speed, wind direction, and air temperature, used as inputs to the multilayer diffusion model for the SRM static test is presented
Investigation of thermospheric winds relative to space station orbital altitudes
An investigation of thermospheric winds, relative to the space station orbital altitudes, was made in order to provide information that is useful in an environmental disturbance assessment. Current plans are for this low Earth orbiting facility to orbit at an inclination of 28.5 deg. The orbital altitudes were not yet defined due to the evolutionary configuration of the Space Station. The upper and lower bounds of the orbital altitudes will be based on constraints set by the drag and expected orbital decay and delivery altitude capability of the Shuttle. The orbital altitude will be estimated on the order of 500 km. Neutral winds in the region from about 80 to 600 km which were derived from satellite drag data, Fabry-Perot interferometers, sounding rockets, ground-based optical Doppler techniques, incoherent scatter radar measurements from Millstone Hill combined with the mass spectrometer and lithium trail neutral wind measurements are examined. The equations of motion of the low Earth orbiting facility are also discussed
A review of micrometeoroid flux measurements and models for low orbital altitudes of the Space Station
A review of meteoroid flux measurements and models for low orbital altitudes of the Space Station has been made in order to provide information that may be useful in design studies and laboratory hypervelocity impact tests which simulate micrometeoroids in space for design of the main wall of the Space Station. This report deals with the meteoroid flux mass model, the defocusing and shielding factors that affect the model, the probability of meteoroid penetration of the main wall of a Space Station. Whipple (1947) suggested a meteoroid bumper, a thin shield around the spacecraft at some distance from the wall, as an effective device for reducing penetration, which has been discussed in this report. The equations of the probability of meteoroid penetration, the average annual cumulative total flux, and the equations for the thickness of the main wall and the bumper are presented in this report
Passive Optical Sample Assembly (POSA)
A Passive Optical Sample Assembly (POSA) unit was mounted and flown in the cargo bay of the space shuttle Columbia during the first Orbital Flight Test (OFT-1). A similar unit was mounted in a different location in the cargo bay during the postflight operations. The samples in both POSA arrays were subjected to a series of optical and analytical measurements prior to delivery for installation in the cargo bay and after retrieval of the flight hardware. The final results of a comparison of the two series of measurements are presented. These STS-1 results are based on data obtained from only a portion of one of the ten Induced Environment Contamination Monitor instruments to be flown on several shuttle flights beginning with STS-2. These limited results do not indicate shuttle contamination levels in excess of those anticipated
Downwind hazard calculations for space shuttle launches at Kennedy Space Center and Vandenberg Air Force Base
The quantitative estimates are presented of pollutant concentrations associated with the emission of the major combustion products (HCl, CO, and Al2O3) to the lower atmosphere during normal launches of the space shuttle. The NASA/MSFC Multilayer Diffusion Model was used to obtain these calculations. Results are presented for nine sets of typical meteorological conditions at Kennedy Space Center, including fall, spring, and a sea-breeze condition, and six sets at Vandenberg AFB. In none of the selected typical meteorological regimes studied was a 10-min limit of 4 ppm exceeded
Prediction of engine exhaust concentrations downwind from the Delta-Thor Telsat-A launch of 9 November 1972
Results are presented of the downwind concentrations of engine exhaust by-products from the Delta-Thor Telsat-A vehicle launched from Cape Kennedy, Florida on November 9, 1972 (2014 EST). The meteorological conditions which existed are identified as well as the exhaust cloud rise and the results from the MSFC Multilayer Diffusion Model calculations. These predictions are compared to exhaust cloud sampled data acquired by the Langley Research Center personnel. Values of the surface level concentrations show that very little hydrochloric acid, carbon monoxide, or aluminum oxide reached the ground
- …
