2,050 research outputs found

    A complete classification of which (n,k)(n,k)-star graphs are Cayley graphs

    Full text link
    The (n,k)(n,k)-star graphs are an important class of interconnection networks that generalize star graphs, which are superior to hypercubes. In this paper, we continue the work begun by Cheng et al.~(Graphs and Combinatorics 2017) and complete the classification of all the (n,k)(n,k)-star graphs that are Cayley.Comment: We have proved the conjecture in the first version, thus completed the classification of which (n,k)(n,k)-star graphs are Cayle

    Interaction of Natural Dietary and Herbal Anionic Compounds and Flavonoids with Human Organic Anion Transporters 1 (SLC22A6), 3 (SLC22A8), and 4 (SLC22A11)

    Get PDF
    Active components of complementary/alternative medicines and natural supplements are often anionic compounds and flavonoids. As such, organic anion transporters (OATs) may play a key role in their pharmacokinetic and pharmacological profiles, and represent sites for adverse drug-drug interactions. Therefore, we assessed the inhibitory effects of nine natural products, including flavonoids (catechin and epicatechin), chlorogenic acids (1,3- and 1,5-dicaffeoylquinic acid), phenolic acids (ginkgolic acids (13 : 0), (15 : 1), and (17 : 1)), and the organic acids ursolic acid and 18β-glycyrrhetinic acid, on the transport activity of the human OATs, hOAT1 (SLC22A6), hOAT3 (SLC22A8), and hOAT4 (SLC22A11). Four compounds, 1,3- and 1,5-dicaffeoylquinic acid, ginkgolic acid (17 : 1), and 18β-glycyrrhetinic acid, significantly inhibited hOAT1-mediated transport (50 μM inhibitor versus 1 μM substrate). Five compounds, 1,3- and 1,5-dicaffeoylquinic acid, ginkgolic acids (15 : 1) and (17 : 1), and epicatechin, significantly inhibited hOAT3 transport under similar conditions. Only catechin inhibited hOAT4. Dose-dependency studies were conducted for 1,3-dicaffeoylquinic acid and 18β-glycyrrhetinic acid on hOAT1, and IC50 values were estimated as 1.2 ± 0.4 μM and 2.7 ± 0.2 μM, respectively. These data suggest that 1,3-dicaffeoylquinic acid and 18β-glycyrrhetinic acid may cause significant hOAT1-mediated DDIs in vivo; potential should be considered for safety issues during use and in future drug development

    Active Hydrophilic Components of the Medicinal Herb Salvia miltiorrhiza (Danshen) Potently Inhibit Organic Anion Transporters 1 (Slc22a6) and 3 (Slc22a8)

    Get PDF
    Many active components of herbal products are small organic anions, and organic anion transporters were previously demonstrated to be a potential site of drug-drug interactions. In this study, we assessed the inhibitory effects of six hydrophilic components of the herbal medicine Danshen, lithospermic acid, protocatechuic acid, rosmarinic acid, salvianolic acid A, salvianolic acid B, and tanshinol, on the function of the murine organic anion transporters, mOat1 and mOat3. All of Danshen components significantly inhibited mOat1- and mOat3-mediated substrate uptake () with lithospermic acid (LSA), protocatechuic acid, rosmarinic acid (RMA), and salvianolic acid A (SAA) producing virtually complete inhibition under test conditions. Kinetic analysis demonstrated that LSA, RMA, and SAA were competitive inhibitors. As such, values were estimated as  μM for LSA,  μM for RMA, and  μM for SAA on mOat1-mediated transport, and as  μM for LSA,  μM for RMA, and  μM for SAA on mOat3-mediated transport. These data suggest that herb-drug interactions may occur in vivo on the human orthologs of these transporters in situations of polypharmacy involving Danshen and clinical therapeutics known to be organic anion transporter substrates

    Outdoor performance of a reflective type 3D LCPV system under different climatic conditions

    Get PDF
    Concentrating sunlight and focusing on smaller solar cells increases the power output per unit solar cell area. In the present study, we highlight the design of a low concentrating photovoltaic (LCPV) system and its performance in different test conditions. The system essentially consists of a reflective type 3.6× cross compound parabolic concentrator (CCPC) designed for an acceptance angle of ± 30°, coupled with square shaped laser grooved buried contact (LGBC) silicon solar cells. A heat exchanger is also integrated with the PV system which extracts the thermal energy rejected by the solar cells whilst maintaining its temperature. Indoor characterization is carried out to evaluate the system performance under standard conditions. Results showed a power ratio of 3.12 and an optical efficiency of 73%. The system is placed under outdoor environment on a south facing roof at Penryn, UK with a fixed angular tilt of 50°. The high angular acceptance of the system allows collection of sunlight over a wider range. Results under different climatic conditions are presented and compared with a non-concentrating system under similar conditions. On an average, the LCPV system was found to collect an average of 2.54 times more solar energy than a system without the concentrator

    A coupled optical-thermal-electrical model to predict the performance of hybrid PV/T-CCPC roof-top systems

    Get PDF
    A crossed compound parabolic concentrator (CCPC) is applied into a photovoltaic/thermal (PV/T) hybrid solar collector, i.e. concentrating PV/T (CPV/T) collector, to develop new hybrid roof-top CPV/T systems. However, to optimise the system configuration and operational parameters as well as to predict their performances, a coupled optical, thermal and electrical model is essential. We establish this model by integrating a number of submodels sourced from literature as well as from our recent work on incidence-dependent optical efficiency, six-parameter electrical model and scaling law for outdoor conditions. With the model, electrical performance and cell temperature are predicted on specific days for the roof-top systems installed in Glasgow, Penryn and Jaen. Results obtained by the proposed model reasonably agree with monitored data and it is also clarified that the systems operate under off-optimal operating condition. Long-term electric performance of the CPV/T systems is estimated as well. In addition, effects of transient terms in heat transfer and diffuse solar irradiance on electric energy are identified and discussed

    Indoor characterization of a reflective type 3D LCPV system

    Get PDF
    This is the final version of the article. Available from AIP Publishing via the DOI in this record.Low concentrating photovoltaic (LCPV) systems produces higher electrical output per unit solar cell compared to typical PV systems. The high efficiency Si solar cells can be utilized with little design and manufacturing changes for these applications. However, a key barrier towards achieving economic viability and the widespread adoption of LCPV technologies is the losses related to high operating temperature. In the present study, we evaluate the performance 3D low concentration system designed for 3.6x, using a reflective Cross compound parabolic concentrator (CCPC) and a Laser Grooved Buried Contact solar cell having an area of 50∗50mm 2 . Results demonstrate the losses occurring due to the temperature rise of the solar cell under concentration and we analyze the potential which could be utilized for low grade heating applications.The authors gratefully acknowledge financial support received from the EPSRC through Solar Challenge project SUNTRAP (EP/K022156/1). We would also like to thank the Super Solar Hub for providing us with the travel grant for this conference

    Design and characterization of hybrid III–V concentrator photovoltaic–thermoelectric receivers under primary and secondary optical elements

    Get PDF
    Lattice-matched monolithic triple-junction Concentrator Photovoltaic (CPV) cells (InGa(0.495)P/GaIn(0.012)As/Ge) were electrically and thermally interfaced to two Thermoelectric (TE) Peltier module designs. An electrical and thermal model of the hybrid receivers was modelled in COMSOL Multiphysics software v5.3 to improve CPV cell cooling whilst increasing photon energy conversion efficiency. The receivers were measured for current-voltage characteristics with the CPV cell only (with sylguard encapsulant), under single secondary optical element (SOE) at x2.5 optical concentration, and under Fresnel lens primary optical element (POE) concentration between x313 and x480. Measurements were taken in solar simulators at Cardiff and Jaén Universities, and on-sun with dual-axis tracking at Jaén University. The hybrid receivers were electrically, thermally and theoretically investigated. The electrical performance data for the cells under variable irradiance and cell temperature conditions were measured using the integrated thermoelectric module as both a temperature sensor and as a solid-state heat pump. The performance of six SOE-CPV-TE hybrid devices were evaluated within two 3-receiver strings under primary optical concentration with measured acceptance angles of 1.00o and 0.89o, similar to commercially sourced CPV modules. A six-parameter one-diode equivalent electrical model was developed for the multi-junction CPV cells with SOE and POE. This was applied to extract six model parameters with the experimental I-V curves of type A receiver at 1, 3 and 500 concentration ratios. Standard test conditions (1000W/m2, 25oC and AM1.5G spectrum) were assumed based on trust-region-reflective least squares algorithm in MATLAB. The model fitted the experimental I-V curves satisfactorily with a mean error of 4.44%, and the optical intensity gain coefficient of SOE and POE is as high as 0.91, in comparison with 0.50-0.86 for crossed compound parabolic concentrators (CCPC). The determined values of diode reverse saturation current, combined series resistance and shunt resistance were similar to those of monocrystalline PV cell/modules in our previous publications. The model may be applicable to performance prediction of multi-junction CPV cells in the future

    A comparison of 3D particle, fluid and hybrid simulations for negative streamers

    Full text link
    In the high field region at the head of a discharge streamer, the electron energy distribution develops a long tail. In negative streamers, these electrons can run away and contribute to energetic processes such as terrestrial gamma-ray and electron flashes. Moreover, electron density fluctuations can accelerate streamer branching. To track energies and locations of single electrons in relevant regions, we have developed a 3D hybrid model that couples a particle model in the region of high fields and low electron densities with a fluid model in the rest of the domain. Here we validate our 3D hybrid model on a 3D (super-)particle model for negative streamers in overvolted gaps, and we show that it almost reaches the computational efficiency of a 3D fluid model. We also show that the extended fluid model approximates the particle and the hybrid model well until stochastic fluctuations become important, while the classical fluid model underestimates velocities and ionization densities. We compare density fluctuations and the onset of branching between the models, and we compare the front velocities with an analytical approximation
    corecore