1,768 research outputs found
Calculations of electric currents in Europa
Electrical currents should flow in the Galilean satellite, Europa, because it is located in Jupiter's corotating magnetosphere. The possible magnitudes of these currents are calculated by assuming that Europa is a differentiated body consisting of an outer H2O layer and a silicate core. Two types of models are considered here: one in which the water is completely frozen and a second in which there is an intermediate liquid layer. For the transverse electric mode (eddy currents), the calculated current density in a liquid layer is approximately 10 to the -5/Am. For the transverse magnetic mode (unipolar generator), the calculated current density in the liquid is severely constrained by the ice layer to a range of only 10 to the -10 to -11th power/ Am, for a total H2O thickness of 100 km, provided that neither layer is less than 4 km thick. The current density is less for a completely frozen H2O layer. If transient cracks were to appear in the ice layer, thereby exposing liquid, the calculated current density could rise to a range of 10 to the -6 to 10 to the -5/Am, depending on layer thicknesses, which would require an exposed area of 10 to the -9 to 10 to the -8 of the Europa surface. The corresponding total current of 2.3x10 to the 5th power A could in 1 yr. electrolyze 7x10 to the 5th power kg of water (and more if the cells were in series), and thereby store up to 10 the 8th power J of energy, but it is not clear how electrolysis can take place in the absence of suitable electrodes. Electrical heating would be significant only if the ice-layer thickness were on the order of 1 m, such as might occur if an exposed liquid surface were to freeze over; the heating under this condition could hinder the thickening of the ice layer
The Effects of Stacking on the Configurations and Elasticity of Single Stranded Nucleic Acids
Stacking interactions in single stranded nucleic acids give rise to
configurations of an annealed rod-coil multiblock copolymer. Theoretical
analysis identifies the resulting signatures for long homopolynucleotides: A
non monotonous dependence of size on temperature, corresponding effects on
cyclization and a plateau in the extension force law. Explicit numerical
results for poly(dA) and poly(rU) are presented.Comment: 4 pages and 2 figures. Accepted in Phys. Rev. E Rapid Com
A modified monomolecular film test for micro-quantities of lipids in foods
This bulletin is a report on Department of Poultry Husbandry research project 17, Egg Utilization--P. [3].Digitized 2007 AES.Includes bibliographical references (page 30)
On malfunctioning software
Artefacts do not always do what they are supposed to, due to a variety of reasons, including manufacturing problems, poor maintenance, and normal wear-and-tear. Since software is an artefact, it should be subject to malfunctioning in the same sense in which other artefacts can malfunction. Yet, whether software is on a par with other artefacts when it comes to malfunctioning crucially depends on the abstraction used in the analysis. We distinguish between “negative” and “positive” notions of malfunction. A negative malfunction, or dysfunction, occurs when an artefact token either does not (sometimes) or cannot (ever) do what it is supposed to. A positive malfunction, or misfunction, occurs when an artefact token may do what is supposed to but, at least occasionally, it also yields some unintended and undesirable effects. We argue that software, understood as type, may misfunction in some limited sense, but cannot dysfunction. Accordingly, one should distinguish software from other technical artefacts, in view of their design that makes dysfunction impossible for the former, while possible for the latter
Micro-fabrication of Carbon Structures by Pattern Miniaturization in Resorcinol-Formaldehyde Gel
A simple and novel method to fabricate and miniaturize surface and
sub-surface micro-structures and micro-patterns in glassy carbon is proposed
and demonstrated. An aqueous resorcinol-formaldehyde (RF) sol is employed for
micro-molding of the master-pattern to be replicated, followed by controlled
drying and pyrolysis of the gel to reproduce an isotropically shrunk replica in
carbon. The miniaturized version of the master-pattern thus replicated in
carbon is about one order of magnitude smaller than original master by
repeating three times the above cycle of molding and drying. The
micro-fabrication method proposed will greatly enhance the toolbox for a facile
fabrication of a variety of Carbon-MEMS and C-microfluidic devices.Comment: 16 pages, 5 figure
Dual-barrel conductance micropipet as a new approach to the study of ionic crystal dissolution kinetics
A new approach to the study of ionic crystal dissolution kinetics is described, based on the use of a dual-barrel theta conductance micropipet. The solution in the pipet is undersaturated with respect to the crystal of interest, and when the meniscus at the end of the micropipet makes contact with a selected region of the crystal surface, dissolution occurs causing the solution composition to change. This is observed, with better than 1 ms time resolution, as a change in the ion conductance current, measured across a potential bias between an electrode in each barrel of the pipet. Key attributes of this new technique are: (i) dissolution can be targeted at a single crystal surface; (ii) multiple measurements can be made quickly and easily by moving the pipet to a new location on the surface; (iii) materials with a wide range of kinetics and solubilities are open to study because the duration of dissolution is controlled by the meniscus contact time; (iv) fast kinetics are readily amenable to study because of the intrinsically high mass transport rates within tapered micropipets; (v) the experimental geometry is well-defined, permitting finite element method modeling to allow quantitative analysis of experimental data. Herein, we study the dissolution of NaCl as an example system, with dissolution induced for just a few milliseconds, and estimate a first-order heterogeneous rate constant of 7.5 (±2.5) × 10–5 cm s–1 (equivalent surface dissolution flux ca. 0.5 μmol cm–2 s–1 into a completely undersaturated solution). Ionic crystals form a huge class of materials whose dissolution properties are of considerable interest, and we thus anticipate that this new localized microscale surface approach will have considerable applicability in the future
Thermal tides in the Martian middle atmosphere as seen by the Mars Climate Sounder
The first systematic observations of the middle atmosphere of Mars (35–80km) with the Mars Climate Sounder (MCS) show dramatic patterns of diurnal thermal variation, evident in retrievals of temperature and water ice opacity. At the time of writing, the data set of MCS limb retrievals is sufficient for spectral analysis within a limited range of latitudes and seasons. This analysis shows that these thermal variations are almost exclusively associated with a diurnal thermal tide. Using a Martian general circulation model to extend our analysis, we show that the diurnal thermal tide dominates these patterns for all latitudes and all seasons
Communications Biophysics
Contains research objectives and summary of research.National Institutes of Health (Grant 5 PO1 GM14940-07)National Institutes of Health (Grant 1 RO1 NS11000-01)Clarence J. LeBel FundNational Institutes of Health (Grant 1 RO1 NS10737-01)National Aeronautics and Space Administration (Grant NGL 22-009-304)Boston City Hospital Purchase Order 1176-21335B-D Electrodyne Division, Becton Dickinson and Company (Grant)Chicago Musical Instrument Company (Grant
Contralateral routing of signals disrupts monaural level and spectral cues to sound localisation on the horizontal plane
Objectives: Contra-lateral routing of signals (CROS) devices re-route sound between the deaf and hearing ears of unilaterally-deaf individuals. This rerouting would be expected to disrupt access to monaural level cues that can support monaural localisation in the horizontal plane. However, such a detrimental effect has not been confirmed by clinical studies of CROS use. The present study aimed to exercise strict experimental control over the availability of monaural cues to localisation in the horizontal plane and the fitting of the CROS device to assess whether signal routing can impair the ability to locate sources of sound and, if so, whether CROS selectively disrupts monaural level or spectral cues to horizontal location, or both.
Design: Unilateral deafness and CROS device use were simulated in twelve normal hearing participants. Monaural recordings of broadband white noise presented from three spatial locations (-60°, 0°, and +60°) were made in the ear canal of a model listener using a probe microphone with and without a CROS device. The recordings were presented to participants via an insert earphone placed in their right ear. The recordings were processed to disrupt either monaural level or spectral cues to horizontal sound location by roving presentation level or the energy across adjacent frequency bands, respectively. Localisation ability was assessed using a three-alternative forced-choice spatial discrimination task.
Results: Participants localised above chance levels in all conditions. Spatial discrimination accuracy was poorer when participants only had access to monaural spectral cues compared to when monaural level cues were available. CROS use impaired localisation significantly regardless of whether level or spectral cues were available. For both cues, signal re-routing had a detrimental effect on the ability to localise sounds originating from the side of the deaf ear (-60°). CROS use also impaired the ability to use level cues to localise sounds originating from straight ahead (0°).
Conclusions: The re-routing of sounds can restrict access to the monaural cues that provide a basis for determining sound location in the horizontal plane. Perhaps encouragingly, the results suggest that both monaural level and spectral cues may not be disrupted entirely by signal re-routing and that it may still be possible to reliably identify sounds originating on the hearing side
Fabrication and characterization of dual function nanoscale pH-scanning ion conductance microscopy (SICM) probes for high resolution pH mapping
The easy fabrication and use of nanoscale dual function pH-scanning ion conductance microscopy (SICM) probes is reported. These probes incorporate an iridium oxide coated carbon electrode for pH measurement and an SICM barrel for distance control, enabling simultaneous pH and topography mapping. These pH-SICM probes were fabricated rapidly from laser pulled theta quartz pipets, with the pH electrode prepared by in situ carbon filling of one of the barrels by the pyrolytic decomposition of butane, followed by electrodeposition of a thin layer of hydrous iridium oxide. The other barrel was filled with an electrolyte solution and Ag/AgCl electrode as part of a conductance cell for SICM. The fabricated probes, with pH and SICM sensing elements typically on the 100 nm scale, were characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and various electrochemical measurements. They showed a linear super-Nernstian pH response over a range of pH (pH 2–10). The capability of the pH-SICM probe was demonstrated by detecting both pH and topographical changes during the dissolution of a calcite microcrystal in aqueous solution. This system illustrates the quantitative nature of pH-SICM imaging, because the dissolution process changes the crystal height and interfacial pH (compared to bulk), and each is sensitive to the rate. Both measurements reveal similar dissolution rates, which are in agreement with previously reported literature values measured by classical bulk methods
- …
