82 research outputs found

    Chirality of Light in Hybrid Modes of Vacuum-clad Ultrathin Optical Fibers

    Get PDF
    We investigate chirality of light in the quasicircularly polarized fundamental HE11 mode and thequasicircularly polarized higher-order hybrid modes of vacuum-clad ultrathin optical fibers. Weshow that, for a given fiber with the parameters in the range of experimental interest, the higherorder modes have smaller optical chirality per unit energy than the fundamental mode. The sign ofthe chirality per unit energy of a HE or EH mode is the same as or opposite to, respectively, thesign of the phase circulation direction. Outside the fiber, the fields in the quasicircularly polarizedHE11 mode and the quasicircularly polarized higher-order HE21 and HE31 modes are superchiral

    Naturally-acquired dengue virus infections do not reduce short-term survival of infected Aedes aegypti from Ho Chi Minh City, Vietnam

    Get PDF
    Transmission of dengue virus (DENV) from mosquito to human is dependent upon the survival of the mosquito beyond the virus extrinsic incubation period. Previous studies report conflicting results of the effects of DENV on Aedes aegypti survival. Here, we describe the effect of DENV on the short-term survival (up to 12 d) of 4,321 Ae. aegypti mosquitoes blood-fed on 150 NS1-positive dengue patients hospitalized in the Hospital for Tropical Diseases, Ho Chi Minh City, Vietnam. Mosquito survival was not different between cohorts that fed upon blood from which 0% of mosquitoes became DENV infected (N = 88 feeds), or 100% became infected (N = 116 feeds). Subgroup analysis also did not reveal serotype-dependent differences in survival, nor a relationship between survival and human plasma viremia levels. These results suggest that DENV infection adds minimal cost to Ae. aegypti, an important finding when parameterizing the vector competence of this mosquito

    Tracking modifications to implementation strategies: a case study from SNaP - a hybrid type III randomized controlled trial to scale up integrated systems navigation and psychosocial counseling for PWID with HIV in Vietnam

    Get PDF
    Introduction Evaluation of implementation strategies is core to implementation trials, but implementation strategies often deviate from the original plan to adjust to the real-world conditions. The optimal approach to track modifications to implementation strategies is unclear, especially in low-resource settings. Using data from an implementation trial for people who inject drugs (PWID) with HIV in Vietnam, we describe the tracking of implementation strategy modifications and present findings of this process. Methods SNaP (Systems Navigation and Psychosocial Counseling) is a hybrid type-III effectiveness-implementation randomized controlled trial aiming to scale up the evidence-based intervention, integrated systems navigation and psychosocial counseling, for PWID with HIV in Vietnam. Forty-two HIV testing sites were randomized 1:1 to a standard or tailored arm. While the standard arm (SA) received a uniform package of strategies, implementation strategies for the tailored arm (TA) were tailored to address specific needs of each site. The central research team also met monthly with the TA to document how their tailored strategies were implemented over time. Five components were involved in the tracking process: describing the planned strategies; tracking strategy use; monitoring barriers and solutions; describing modifications; and identifying and describing any additional strategies. Results Our approach allowed us to closely track the modifications to implementation strategies in the tailored arms every month. TA sites originally identified 27 implementation strategies prior to implementation. During implementation, five strategies were dropped by four sites and two new strategies were added to twelve sites. Modifications of five strategies occurred at four sites to accommodate their changing needs and resources. Difficulties related to the COVID-19 pandemic, low number of participants recruited, high workload at the clinic, lack of resources for HIV testing and high staff turnover were among barriers of implementing the strategies. A few challenges to tracking modifications were noted, including the considerable amount of time and efforts needed as well as the lack of motivation from site staff to track and keep written documentations of modifications. Conclusions We demonstrated the feasibility of a systematic approach to tracking implementation strategies for a large-scale implementation trial in a low-resource setting. This process could be further enhanced and replicated in similar settings to balance the rigor and feasibility of implementation strategy tracking. Our findings can serve as additional guidelines for future researchers planning to report and track modifications to implementation strategies in large, complex trials. Trial registration: clinicaltrials.gov ID: NCT03952520 (first posted 2019-05-16)

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Feasibility of perfusion cardiovascular magnetic resonance in paediatric patients

    Get PDF
    AIMS: As coronary artery disease may also occur during childhood in some specific conditions, we sought to assess the feasibility and accuracy of perfusion cardiovascular magnetic resonance (CMR) in paediatric patients. METHODS AND RESULTS: First-pass perfusion CMR studies were performed under pharmacological stress with adenosine and by using a hybrid echo-planar pulse sequence with slice-selective saturation recovery preparation. Fifty-six perfusion CMR examinations were performed in 47 patients. The median age was 12 years (1 month-18 years), and weight 42.8 kg (2.6-82 kg). General anaesthesia was required in 18 patients. Mean examination time was 67 +/- 19 min. Diagnostic image quality was obtained in 54/56 examinations. In 23 cases the acquisition parameters were adapted to patient's size. Perfusion CMR was abnormal in 16 examinations. The perfusion defects affected the territory of the left anterior descending coronary artery in 11, of the right coronary artery in 3, and of the circumflex coronary artery in 2 cases. Compared to coronary angiography, perfusion CMR showed a sensitivity of 87% (CI 52-97%) and a specificity of 95% (CI 79-99%). CONCLUSION: In children, perfusion CMR is feasible and accurate. In very young children (less than 1 year old), diagnostic image quality may be limited

    Performance of adenosine “stress-only” perfusion MRI in patients without a history of myocardial infarction: a clinical outcome study

    Get PDF
    To assess the diagnostic value of adenosine “stress-only” myocardial perfusion MR for ischemia detection as an indicator for coronary angiography in patients without a prior myocardial infarction and a necessity to exclude ischemia. Adenosine perfusion MRI was performed at 1.5 T in 139 patients with a suspicion of ischemia and no prior myocardial infarction. After 3 min of adenosine infusion a perfusion sequence was started. Patients with a perfusion defect were referred to coronary angiography (CAG). Patients with a normal perfusion were enrolled in follow-up. Fourteen out of 139 patients (10.1%) had a perfusion defect indicative of ischemia. These patients underwent a coronary angiogram, which showed complete agreement with the perfusion images. 125 patients with a normal myocardial perfusion entered follow-up (median 672 days, range 333–1287 days). In the first year of follow-up one Major Adverse Coronary Event (MACE) occurred and one patient had new onset chest pain with a confirmed coronary stenosis. Reaching a negative predictive value for MACE of 99.2% and for any coronary event of 98.4%. At 2 year follow-up no additional MACE occurred. Sensitivity of adenosine perfusion MR for MACE is 93.3% and specificity and positive predictive value are 100%. Adenosine myocardial perfusion MR for the detection of myocardial ischemia in a “stress-only” protocol in patients without prior myocardial infarctions, has a high diagnostic accuracy. This fast examination can play an important role in the evaluation of patients without prior myocardial infarctions and a necessity to exclude ischemia

    Meta-analysis of the diagnostic performance of stress perfusion cardiovascular magnetic resonance for detection of coronary artery disease

    Get PDF
    <p>Abstract</p> <p>Aim</p> <p>Evaluation of the diagnostic accuracy of stress perfusion cardiovascular magnetic resonance for the diagnosis of significant obstructive coronary artery disease (CAD) through meta-analysis of the available data.</p> <p>Methodology</p> <p>Original articles in any language published before July 2009 were selected from available databases (MEDLINE, Cochrane Library and BioMedCentral) using the combined search terms of magnetic resonance, perfusion, and coronary angiography; with the exploded term coronary artery disease. Statistical analysis was only performed on studies that: (1) used a [greater than or equal to] 1.5 Tesla MR scanner; (2) employed invasive coronary angiography as the reference standard for diagnosing significant obstructive CAD, defined as a [greater than or equal to] 50% diameter stenosis; and (3) provided sufficient data to permit analysis.</p> <p>Results</p> <p>From the 263 citations identified, 55 relevant original articles were selected. Only 35 fulfilled all of the inclusion criteria, and of these 26 presented data on patient-based analysis. The overall patient-based analysis demonstrated a sensitivity of 89% (95% CI: 88-91%), and a specificity of 80% (95% CI: 78-83%). Adenosine stress perfusion CMR had better sensitivity than with dipyridamole (90% (88-92%) versus 86% (80-90%), P = 0.022), and a tendency to a better specificity (81% (78-84%) versus 77% (71-82%), P = 0.065).</p> <p>Conclusion</p> <p>Stress perfusion CMR is highly sensitive for detection of CAD but its specificity remains moderate.</p
    corecore