1,773 research outputs found

    Dose-dependent new bone formation by extracorporeal shock wave application on the intact femur of rabbits

    Get PDF
    Background: Whereas various molecular working mechanisms of shock waves have been demonstrated, no study has assessed in detail the influence of varying energy flux densities (EFD) on new bone formation in vivo. Methods: Thirty Chinchilla bastard rabbits were randomly assigned to 5 groups (EFD 0.0, 0.35, 0.5, 0.9 and 1.2 mJ/mm(2)) and treated with extracorporeal shock waves at the distal femoral region (1,500 pulses; 1 Hz frequency). To investigate new bone formation, animals were injected with oxytetracycline at days 5-9 after shock wave application and sacrificed on day 10. Histological sections of all animals were examined using broad-band epifluorescent illumination, contact microradiography and Giemsa-Eosin staining. Results: Application of shock waves induced new bone formation beginning with 0.5 mJ/mm(2) EFD and increasing with 0.9 mJ/mm(2) and 1.2 mJ/mm(2). The latter EFD resulted in new bone formation also on the dorsal cortical bone; cortical fractures and periosteal detachment also occurred. Conclusion: Here, for the first time, a threshold level is presented for new bone formation after applying shock waves to intact bone in vivo. The findings of this study are of considerable significance for preventing unwanted side effects in new approaches in the clinical application of shock waves. Copyright (c) 2008 S. Karger AG, Basel

    Adaptive region growing impulse noise estimator for color images

    Get PDF
    In this paper, a novel region growing impulse noise estimator for color images is proposed. The aim of this estimator is to distinguish noisy pixels from uncorrupted pixels and subsequently measure the noise proportion efficiently. We use a region growing technique to segment the images into clusters of pixels and propose an adaptive decision scheme to measure the noise proportion. Performance analyses show the proposed scheme outperforms some of the state-of-the art techniques

    Exhumation of the Sierra de Cameros (Iberian Range, Spain): constraints from low-temperature thermochronology

    Get PDF
    We present new fission-track and (U–Th)/He data from apatite and zircon in order to reconstruct the exhumation of the Sierra de Cameros, in the northwestern part of Iberian Range, Spain. Zircon fission-track ages from samples from the depocentre of the basin were reset during the metamorphic peak at approximately 100 Ma. Detrital apatites from the uppermost sediments retain fission-track age information that is older than the sediment deposition age, indicating that these rocks have not exceeded 110 8C. Apatites from deeper in the stratigraphic sequence of the central part of the basin have fission-track ages of around 40 Ma, significantly younger than the stratigraphic age, recording the time of cooling after peak metamorphic conditions. Apatite (U–Th)/He ages in samples from these sediments are 31–40 Ma and record the last period of cooling during Alpine compression. The modelled thermal history derived from the uppermost sediments indicates that the thermal pulse associated with peak metamorphism was rapid, and that the region has cooled continuously to the present. The estimated palaeogeothermal gradient is around 86 8C km21 and supports a tectonic model with a thick sedimentary fill (c. 8 km) and explains the origin of the low-grade metamorphism observed in the oldest sediments

    Outcomes of haploidentical stem cell transplantation for chronic lymphocytic leukemia: a retrospective study on behalf of the chronic malignancies working party of the EBMT

    Get PDF
    Allogeneic hematopoietic stem cell transplantation (HCT) may result in long-term disease control in high-risk chronic lymphocytic leukemia (CLL). Recently, haploidentical HCT is gaining interest because of better outcomes with post-transplantation cyclophosphamide (PTCY). We analyzed patients with CLL who received an allogeneic HCT with a haploidentical donor and whose data were available in the EBMT registry. In total 117 patients (74% males) were included; 38% received PTCY as GVHD prophylaxis. For the whole study cohort OS at 2 and 5 yrs was 48 and 38%, respectively. PFS at 2 and 5 yrs was 38 and 31%, respectively. Cumulative incidence (CI) of NRM in the whole group at 2 and 5 years were 40 and 44%, respectively. CI of relapse at 2 and 5 yrs were 22 and 26%, respectively. All outcomes were not statistically different in patients who received PTCY compared to other types of GVHD prophylaxis. In conclusion, results of haploidentical HCT in CLL seem almost identical to those with HLA-matched donors. Thereby, haploidentical HCT is an appropriate alternative in high risk CLL patients with a transplant indication but no available HLA-matched donor. Despite the use of PTCY, the CI of relapse seems not higher than observed after HLA-matched HCT

    Mortality of Patients with Hematological Malignancy after Admission to the Intensive Care Unit

    Get PDF
    Background: The admission of patients with malignancies to an intensive care unit (ICU) still remains a matter of substantial controversy. The identification of factors that potentially influence the patient outcome can help ICU professionals make appropriate decisions. Patients and Methods: 90 adult patients with hematological malignancy (leukemia 47.8%, high-grade lymphoma 50%) admitted to the ICU were analyzed retrospectively in this single-center study considering numerous variables with regard to their influence on ICU and day-100 mortality. Results: The median simplified acute physiology score (SAPS) II at ICU admission was 55 (ICU survivors 47 vs. 60.5 for non-survivors). The overall ICU mortality rate was 45.6%. With multivariate regression analysis, patients admitted with sepsis and acute respiratory failure had a significantly increased ICU mortality (sepsis odds ratio (OR) 9.12, 95% confidence interval (CI) 1.1-99.7, p = 0.04; respiratory failure OR 13.72, 95% CI 1.39-136.15, p = 0.025). Additional factors associated with an increased mortality were: high doses of catecholamines (ICU: OR 7.37, p = 0.005; day 100: hazard ratio (HR) 2.96, p < 0.0001), renal replacement therapy (day 100: HR 1.93, p = 0.026), and high SAPS II (ICU: HR 1.05, p = 0.038; day 100: HR 1.2, p = 0.027). Conclusion: The decision for or against ICU admission of patients with hematological diseases should become increasingly independent of the underlying malignant disease

    Early age exposure to moisture damage and systemic inflammation at the age of 6 years

    Get PDF
    Cross-sectional studies have shown that exposure to indoor moisture damage and mold may be associated with subclinical inflammation. Our aim was to determine whether early age exposure to moisture damage or mold is prospectively associated with subclinical systemic inflammation or with immune responsiveness in later childhood. Home inspections were performed in children's homes in the first year of life. At age 6 years, subclinical systemic inflammation was measured by serum C-reactive protein(CRP) and blood leucocytes and immune responsiveness by ex vivo production of interleukin 1-beta(IL-1beta), IL-6 and tumor necrosis factor-alpha(TNF-alpha) in whole blood cultures without stimulation or after 24h stimulation with phorbol 12-myristate 13-acetate and ionomycin(PI), lipopolysaccharide(LPS) or peptidoglycan(PPG) in 251 to 270 children. Moisture damage in child's main living areas in infancy was not significantly associated with elevated levels of CRP or leucocytes at 6 years. In contrast, there was some suggestion for an effect on immune responsiveness, as moisture damage with visible mold was positively associated with LPS-stimulated production of TNF-alpha and minor moisture damage was inversely associated with PI-stimulated IL-1beta. While early life exposure to mold damage may have some influence on later immune responsiveness, it does not seem to increase subclinical systemic inflammation in later life. This article is protected by copyright. All rights reserved

    Soft capacitor fibers using conductive polymers for electronic textiles

    Full text link
    A novel, highly flexible, conductive polymer-based fiber with high electric capacitance is reported. In its crossection the fiber features a periodic sequence of hundreds of conductive and isolating plastic layers positioned around metallic electrodes. The fiber is fabricated using fiber drawing method, where a multi-material macroscopic preform is drawn into a sub-millimeter capacitor fiber in a single fabrication step. Several kilometres of fibers can be obtained from a single preform with fiber diameters ranging between 500um -1000um. A typical measured capacitance of our fibers is 60-100 nF/m and it is independent of the fiber diameter. For comparison, a coaxial cable of the comparable dimensions would have only ~0.06nF/m capacitance. Analysis of the fiber frequency response shows that in its simplest interrogation mode the capacitor fiber has a transverse resistance of 5 kOhm/L, which is inversely proportional to the fiber length L and is independent of the fiber diameter. Softness of the fiber materials, absence of liquid electrolyte in the fiber structure, ease of scalability to large production volumes, and high capacitance of our fibers make them interesting for various smart textile applications ranging from distributed sensing to energy storage

    Standardization of measles, mumps and rubella assays to enable comparisons of seroprevalence data across 21 European countries and Australia

    Get PDF
    The aim of the European Sero-Epidemiology Network is to establish comparability of the serological surveillance of vaccine-preventable diseases in Europe. The designated reference laboratory (RL) for measles, mumps, rubella (MMR) prepared and tested a panel of 151 sera by the reference enzyme immunoassay (rEIA). Laboratories in 21 countries tested the panel for antibodies against MMR using their usual assay (a total of 16 different EIAs) and the results were plotted against the reference results in order to obtain equations for the standardization of national serum surveys. The RL also tested the panel by the plaque neutralization test (PNT). Large differences in qualitative results were found compared to the RL. Well-fitting standardization equations with R20·8 were obtained for almost all laboratories through regression of the quantitative results against those of the RL. When compared to PNT, the rEIA had a sensitivity of 95·3%, 92·8% and 100% and a specificity of 100%, 87·1% and 92·8% for measles, mumps and rubella, respectively. The need for standardization was highlighted by substantial inter-country differences. Standardization was successful and the selected standardization equations allowed the conversion of local serological results into common units and enabled direct comparison of seroprevalence data of the participating countrie

    Anthracycline-Induced Cardiotoxicity: Cardiac Monitoring by Continuous Wave-Doppler Ultrasound Cardiac Output Monitoring and Correlation to Echocardiography

    Get PDF
    Background: Anthracyclines are agents with a well-known cardiotoxicity. The study sought to evaluate the hemodynamic response to an anthracycline using real-time continuous-wave (CW)-Doppler ultrasound cardiac output monitoring (USCOM) and echocardiography in combination with serum biomarkers. Methods: 50 patients (26 male, 24 female, median age 59 years) suffering from various types of cancer received an anthracycline-based regimen. Patients' responses were measured at different time points (T0 prior to infusion, T1 6 h post infusion, T2 after 1 day, T3 after 7 days, and T4 after 3 months) with CW-Doppler ultrasound (T0-T4) and echocardiography (T1, T4) for hemodynamic parameters such as stroke volume (SV; SVUSCOM ml) and ejection fraction (EF; EFechocardiography%) and with NT-pro-BNP and hs-Troponin T (T0-T4). Results: During the 3-month observation period, the relative decrease in the EF determined by echocardiography was -2.1% (Delta T0-T4, T0 71 +/- 7.8%, T4 69.5 +/- 7%, p = 0.04), whereas the decrease in SV observed using CW-Doppler was -6.5% (Delta T0-T4, T0 54 +/- 19.2 ml, T4 50.5 +/- 20.6 ml, p = 0.14). The kinetics for serum biomarkers were inversely correlated. Conclusions: Combining real-time CW-Doppler USCOM and serum biomarkers is feasible for monitoring the immediate and chronic hemodynamic changes during an anthracycline-based regimen; the results obtained were comparable to those from echocardiography
    corecore