23 research outputs found
A 6 Week Randomized Double-Blind Placebo-Controlled Trial of Ziprasidone for the Acute Depressive Mixed State
OBJECTIVE: To examine the efficacy of ziprasidone vs. placebo for the depressive mixed state in patients with bipolar disorder type II or major depressive disorder (MDD). METHODS: 73 patients were randomized in a double-blinded, placebo-controlled study to ziprasidone (40-160 mg/d) or placebo for 6 weeks. They met DSM-IV criteria for a major depressive episode (MDE), while also meeting 2 or 3 (but not more nor less) DSM-IV manic criteria. They did not meet DSM-IV criteria for a mixed or manic episode. Baseline psychotropic drugs were continued unchanged. The primary endpoint measured was Montgomery-Åsberg Depression Rating Scale (MADRS) scores over time. The mean dose of ziprasidone was 129.7±45.3 mg/day and 126.1±47.1 mg/day for placebo. RESULTS: The primary outcome analysis indicated efficacy of ziprasidone versus placebo (p = 0.0038). Efficacy was more pronounced in type II bipolar disorder than in MDD (p = 0.036). Overall ziprasidone was well tolerated, without notable worsening of weight or extrapyramidal symptoms. CONCLUSIONS: There was a statistically significant benefit with ziprasidone versus placebo in this first RCT of any medication for the provisional diagnostic concept of the depressive mixed state. TRIAL REGISTRATION: Clinicaltrials.gov NCT00490542
Comparing oxytocin and cortisol regulation in a double-blind, placebo-controlled, hydrocortisone challenge pilot study in children with autism and typical development
Oscillatory flow and temperature fields in an open tube with temperature difference across the ends
The oscillating flow and temperature field in an open tube subjected to cryogenic temperature at the cold end and ambient temperature at the hot end is studied numerically. The flow is driven by a time-wise sinusoidally varying pressure at the cold end. The conjugate problem takes into account the interaction of oscillatory flow with the heat conduction in the tube wall. The full set of compressible flow equations with axisymmetry assumption are solved with a pressure correction algorithm. Parametric studies are conducted with frequencies of 5-15 Hz, with one end maintained at 100 K and other end at 300 K. The flow and temperature distributions and the cooldown characteristics are obtained. The frequency and pressure amplitude have negligible effect on the time averaged Nusselt number. Pressure amplitude is an important factor determining the enthalpy flow through the solid wall. The frequency of operation has considerable effect on penetration of temperature into the tube. The density variation has strong influence on property profiles during cooldown. The present study is expected to be of interest in applications such as pulse tube refrigerators and other cryocoolers, where oscillatory flows occur in open tubes. (C) 2011 Elsevier Ltd. All rights reserved
Effect of natural convection on oscillating flow in a pipe with cryogenic temperature difference across the ends
The effect of natural convection on the oscillatory flow in an open-ended pipe driven by a timewise sinusoidally varying pressure at one end and subjected to an ambient-to-cryogenic temperature difference across the ends, is numerically studied. Conjugate effects arising out of the interaction of oscillatory flow with heat conduction in the pipe wall are taken into account by considering a finite thickness wall with an insulated exterior surface. Two cases, namely, one with natural convection acting downwards and the other, with natural convection acting upwards, are considered. The full set of compressible flow equations with axissymmetry are solved using a pressure correction algorithm. Parametric studies are conducted with frequencies in the range 5-15 Hz for an end-to-end temperature difference of 200 and 50 K. Results are obtained for the variation of velocity, temperature. Nusselt number and the phase relationship between mass flow rate and temperature. It is found that the Rayleigh number has a minimal effect on the time averaged Nusselt number and phase angle. However, it does influence the local variation of velocity and Nusselt number over one cycle. The natural convection and pressure amplitude have influence on the energy flow through the gas and solid. (C) 2011 Elsevier Ltd. All rights reserved
Claire Callender, William Locke and Simon Marginson (eds.) 2020. Changing higher education for a changing world. Bloomsbury Higher Education Research Series. London and New York: Bloomsbury Academic/Bloomsbury Publishing plc. xvii + 268 pp. ISBN: HB 978-1-3501-0841-7; ePDF: HB 978-1-3501-0842-4; eBook: HB 978-1-3501-0843-1
CFD simulation of fluid flow and heat transfer in high frequency pulse tube refrigerators
CFD analysis of high frequency miniature pulse tube refrigerators for space applications with thermal non-equilibrium model
High frequency, miniature, pulse tube cryocoolers are extensively used in space applications because of their simplicity. Parametric studies of inertance type pulse tube cooler are performed with different length-to-diameter ratios of the pulse tube with the help of the FLUENT (R) package. The local thermal non-equilibrium of the gas and the matrix is taken into account for the modeling of porous zones, in addition to the wall thickness of the components. Dynamic characteristics and the actual mechanism of energy transfer in pulse are examined with the help of the pulse tube wall time constant. The heat interaction between pulse tube wall and the oscillating gas, leading to surface heat pumping, is quantified. The axial heat conduction is found to reduce the performance of the pulse tube refrigerator. The thermal non-equilibrium predicts a higher cold heat
exchanger temperature compared to thermal equilibrium. The pressure drop through the porous medium has a strong non-linear effect due to the dominating influence of Forchheimer term over that of the linear Darcy term at high operating frequencies. The phase angle relationships among the pressure, temperature and the mass flow rate in the porous zones are also important in determining the performance of pulse tuberefrigerator
