9,970 research outputs found
Measurement of the semileptonic b branching ratios from inclusive leptons in Z decays
From about 1.3 million hadronic Z decays collected with the ALEPH Detector in 1992 and 1993 inclusive muons and electrons have been analysed to measure the semileptonic branching ratios for primary and cascade decays. The analyses take advantage of the high purity sample obtained using lifetime tagging. A fit to the P_perp spectra gives the preliminary results stat syst models BR(b->l) = 0.1101 +/- 0.0010 +/- 0.0021 +0.0024-0.0017 BR(b->c->l) = 0.0768 +/- 0.0018 +/- 0.0031 +0.0034-0.0043 The model dependence has been reduced by using charge correlations in the event rather than fits to the P_perp spectra. A preliminary value of stat syst models BR(b->l) = 0.1101 +/- 0.0023 +/- 0.0028 +/- 0.0011 has been obtained
Calibrazioni e Monitoraggio dell'Esperimento MEG
\documentclass[a4paper,11pt]{article}
\usepackage[latin1]{inputenc}
\usepackage{graphicx}
\usepackage[italian]{babel}
\usepackage[centertags]{amsmath}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsthm}
\usepackage{newlfont}
\usepackage[usenames,dvipsnames]{color}
\title {Calibrazioni e Monitoraggio dell'Esperimento MEG}
\author{ Francesco Tenchini }
\begin{document}
%\maketitle
\begin{center}
\makebox[\textwidth]{
\raisebox{5cm}{
\begin{minipage}[t]{50truecm}\begin{center}{
\hspace*{0.2cm}{\Large \textbf{Universit\`a di
Pisa}}\\ \vspace{0.3cm}
\hspace*{0.2cm}{\textbf{Facolt\`a di Scienze Matematiche Fisiche e
Naturali}}\\ \vspace{0.2cm}
\hspace*{0.2cm}{ \textbf{Corso di Laurea Specialistica in Scienze Fisiche}}\\
\vspace{0.2cm}
\hspace*{0.2cm}{\small{Anno Accademico 2009/2010}}\\
\vspace{0.4cm}
\hspace*{0.2cm}{ Riassunto dell'Elaborato Finale}\\
\vspace{0.4cm}
\hspace*{0.2cm}{\large {\bf Calibrazioni e Monitoraggio dell'Esperimento MEG}}}
\end{center}
\end{minipage}}}
\end{center}
\noindent\hspace*{0.2cm}{Candidato: \bf Francesco Tenchini}
\vspace{0.2cm}
\noindent\hspace*{0.2cm}{Relatore: \bf Prof. Alessandro Baldini}
\vspace{0.7cm}
\noindent L'esperimento MEG si propone di misurare il rapporto di decadimento con una sensibilit\`a pari a , due ordini di grandezza superiore ai risultati ottenuti dal precedente esperimento MEGA.
Il Modello Standard (MS), per il quale la massa dei neutrini \`e nulla, prevede una completa conservazione del numero leptonico, quindi . I recenti risultati sulle oscillazioni di neutrini mostrano che esiste almeno un autostato di massa di neutrino non nullo. Tuttavia il Modello Standard, opportunamente modificato, prevede un valore di attualmente non misurabile ().
I processi di violazione del sapore leptonico (LFV) sono invece previsti in numerose teorie di unificazione supersimmetriche con valori del rapporto di decadimento molto pi\`u elevati, attorno a . Osservare il processo sarebbe quindi un'evidenza importante di fisica oltre il Modello Standard. Una mancata osservazione risulterebbe comunque utile ad imporre limiti pi\`u stringenti alle nuove teorie.
Il decadimento del muone viene studiato in MEG a riposo. La segnatura associata al processo \`e data dall'emissione in coincidenza di un gamma ed un positrone, con un angolo relativo di ed un'energia di MeV.
Il fascio di muoni utilizzato per l'esperimento \`e fornito dal Paul Scherrer Institut (PSI, Villigen, Svizzera) ed \`e il pi\`u intenso fascio continuo di muoni attualmente esistente (). La misura del quadri-impulso del viene eseguita usando il calorimetro a Xenon liquido; la misura del quadri-impulso del positrone viene eseguita usando lo spettrometro COBRA, costituito da un sistema di camere a deriva ed un magnete superconduttore, ed un sistema di rapidi contatori plastici.
A causa dell'elevata precisione richiesta dall'esperimento risulta fondamentale avere sotto controllo tutti i parametri dei rivelatori, in modo da minimizzare le incertezze sistematiche legate alla strumentazione. Per questo motivo \`e necessaria un'accurata calibrazione ed un preciso monitoraggio di tutto l'apparato.
L'elaborato discute i diversi metodi di calibrazione e monitoraggio dell'esperimento, con particolare enfasi su quelli a cui il candidato ha contribuito durante il periodo di tesi.
In particolare si descrive lo sviluppo del sistema di monitoraggio del calorimetro a Xenon mediante da 9 MeV, ottenuti per cattura di neutroni termici nel Nickel. La caratteristica, unica di questo metodo, \`e quella di permettere il monitoraggio del calorimetro in presenza del fascio di muoni, usando un generatore impulsato di neutroni.
Vengono descritti gli studi preliminari di Monte Carlo che hanno portato alla scelta della configurazione del sistema moderatore-nickel; il test di accettazione del generatore di neutroni utilizzato al PSI; e l'osservazione del segnale dei da 9 MeV prodotti.
\`E descritta l'installazione ed il primo test di un nuovo metodo di calibrazione sviluppato per una migliore comprensione dello spettrometro, utilizzato per eseguire la misura dell'impulso e della direzione del positrone. Il metodo si basa sulla diffusione elastica Mott di un fascio monocromatico di positroni su nuclei leggeri.
Infine \`e descritto il montaggio di un sistema pneumatico per il movimento di una sorgente di Americio-Berillio (ulteriore metodo di calibrazione dell'esperimento) e la programmazione del sistema di controllo remoto.
Le attivit\`a sopra riportate sono state svolte al PSI, durante una lunga permanenza del candidato presso il laboratorio.
\end{document
Data Preservation at LEP
The four LEP experiments ALEPH, DELPHI, L3 and OPAL successfully recorded
e+e- collision data during the years 1989 to 2000. As part of the ordinary
evolution in High Energy Physics, these experiments can not be repeated and
their data is therefore unique. This article briefly reviews the data
preservation efforts undertaken by the four experiments beyond the end of data
taking. The current status of the preserved data and associated tools is
summarised.Comment: 7 pages, contribution to proceedings of the "First Workshop on Data
Preservation and Long Term Analysis in HEP
PERLINDUNGAN KONSUMEN TERHADAP MAKANAN JAJANAN YANG MENGANDUNG FORMALIN DAN BORAKS(SUATU PENELITIAN DI KOTA BANDA ACEH)
ABSTRAKNANDA MAULINA SAFIRA,PERLINDUNGAN KONSUMEN TERHADAP 2014MAKANAN JAJANAN YANG MENGANDUNG FORMALIN DAN BORAKS (Studi Penelitian di Kota Banda Aceh)Fakultas Hukum Universitas Syiah Kuala(iv, 63) pp., tabl., bibl., appdx.( RISMAWATI, S.H., M.Hum. )Dalam Pasal 4 huruf a Undang-Undang Perlindungan Konsumen dijelaskan bahwa konsumen memiliki hak atas keselamatan dalam mengkonsumsi barang. Dalam Pasal 67 Undang-Undang Nomor 18 Tahun 2012 tentang Pangan dijelaskan bahwa ketentuan keamanan pangan diselenggarakan untuk menjaga pangan tetap aman dikonsumsi, sehingga terhindar dari kemungkinan cemaran biologis atau kimia yang dapat membahayakan kesehatan manusia. Dalam Peraturan Menteri Kesehatan Nomor 33 Tahun 2012 tentang Bahan Tambahan Pangan disebutkan bahwa bahan yang dilarang digunakan sebagai bahan tambahan pangan diantaranya adalah formalin dan boraks. Pada kenyataannya, di Kota Banda Aceh terdapat masalah dalam mewujudkan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks.Penulisan skripsi ini bertujuan untuk menjelaskan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks, faktor penyebab tidak berjalannya perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks, dan upaya mengatasi hambatan perwujudan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks.Data yang diperlukan dalam tulisan ini adalah data sekunder dan data primer. Data sekunder diperoleh melalui penelitian kepustakaan dilakukan dengan cara membaca peraturan perundang-undangan, buku-buku, surat kabar dan bahan-bahan lain yang berkaitan dengan penelitian ini, dan data primer diperoleh dengan cara mewancarai responden dan informan.Hasil penelitian menunjukkan bahwa perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks di Kota Banda Aceh, belum berjalan sebagaimana yang telah diatur dalam Undang-Undang Nomor 18 Tahun 2012 dan Peraturan Menteri Kesehatan Nomor 33 Tahun 2012. Faktor penyebab tidak berjalannya perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks yaitu kurangnya sosialisasi peraturan perundang-undangan, kurangnya pengawasan, kurangnya ketegasan dalam penerapan sanksi dan kurangnya laporan dari pihak masyarakat.Upaya mengatasi hambatan perwujudan perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks yaitu penyuluhan hukum, pengawasan, peringatan dan pembinaan.Disarankan kepada instansi pemerintahan seperti Dinas Kesehatan dan BBPOM untuk menambah jumlah petugas serta mengalokasikan dana dalam melakukan pemeriksaan dan pengujian makanan jajanan sehingga terselenggaranya perlindungan konsumen terhadap makanan jajanan yang mengandung formalin dan boraks.Banda Ace
Physics Behind Precision
This document provides a writeup of contributions to the FCC-ee mini-workshop
on "Physics behind precision" held at CERN, on 2-3 February 2016.Comment: https://indico.cern.ch/event/469561
Single-hit resolution measurement with MEG II drift chamber prototypes
Drift chambers operated with helium-based gas mixtures represent a common
solution for tracking charged particles keeping the material budget in the
sensitive volume to a minimum. The drawback of this solution is the worsening
of the spatial resolution due to primary ionisation fluctuations, which is a
limiting factor for high granularity drift chambers like the MEG II tracker. We
report on the measurements performed on three different prototypes of the MEG
II drift chamber aimed at determining the achievable single-hit resolution. The
prototypes were operated with helium/isobutane gas mixtures and exposed to
cosmic rays, electron beams and radioactive sources. Direct measurements of the
single hit resolution performed with an external tracker returned a value of
110 m, consistent with the values obtained with indirect measurements
performed with the other prototypes.Comment: 18 pages, 18 figure
Results on Multiple Coulomb Scattering from 12 and 20 GeV electrons on Carbon targets
Multiple scattering effects of 12 and 20 GeV electrons on 8 and 20 mm
thickness carbon targets have been studied with high-resolution silicon
microstrip detectors of the UA9 apparatus at the H8 line at CERN. Comparison of
the scattering angle between data and GEANT4 simulation shows excellent
agreement in the core of the distributions leaving some residual disagreement
in the tails.Comment: 14 pages, 16 figures. Updated to match published versio
Selection of Single Top Events with the CMS Detector at LHC
The detection of single-top events with CMS is discussed. Two selections are proposed, aimed to measure single top production in the Standard Model t- and s-channel, respectively. The perspectives of the measurements for an integrated luminosity of 10 fb-1 are described. The results are based on detailed detector simulations, either based on GEANT4, or on faster techniques. The reconstruction procedures developed by the CMS Collaboration are utilized
Proceedings of the Workshop on Monte Carlo's, Physics and Simulations at the LHC PART II
These proceedings collect the presentations given at the first three meetings
of the INFN "Workshop on Monte Carlo's, Physics and Simulations at the LHC",
held at the Frascati National Laboratories in 2006. The first part of these
proceedings contains pedagogical introductions to several basic topics of both
theoretical and experimental high pT LHC physics. The second part collects more
specialised presentations.Comment: 157 pages, 136 figures; contribution by M. Grazzini has been adde
- …
