    Animal study assessing safety of an acoustic coupling fluid that holds the potential to avoid surgically induced artifacts in 3D ultrasound guided operations

    Get PDF
    BACKGROUND: Use of ultrasound in brain tumor surgery is common. The difference in attenuation between brain and isotonic saline may cause artifacts that degrade the ultrasound images, potentially affecting resection grades and safety. Our research group has developed an acoustic coupling fluid that attenuates ultrasound energy like the normal brain. We aimed to test in animals if the newly developed acoustic coupling fluid may have harmful effects. METHODS: Eight rats were included for intraparenchymal injection into the brain, and if no adverse reactions were detected, 6 pigs were to be included with injection of the coupling fluid into the subarachnoid space. Animal behavior, EEG registrations, histopathology and immunohistochemistry were used in assessment. RESULTS: In total, 14 animals were included, 8 rats and 6 pigs. We did not detect any clinical adverse effects, seizure activity on EEG or histopathological signs of tissue damage. CONCLUSION: The novel acoustic coupling fluid intended for brain tumor surgery appears safe in rats and pigs under the tested circumstances

    Gas chromatography/sniffing port analysis and sensory evaluation of commercially dried bell peppers (Capsicum annuum) after rehydration.

    Get PDF
    Background Image contrast between normal tissue and brain tumours may sometimes appear to be low in intraoperative ultrasound. Ultrasound imaging of strain is an image modality that has been recently explored for intraoperative imaging of the brain. This study aims to investigate differences in image contrast between ultrasound brightness mode (B-mode) images and ultrasound strain magnitude images of brain tumours. Methods Ultrasound radiofrequency (RF) data was acquired during surgery in 15 patients with glial tumours. The data were subsequently processed to provide strain magnitude images. The contrast in the B-mode images and the strain images was determined in assumed normal brain tissue and tumour tissue at selected regions of interest (ROI). Three measurements of contrast were done in the ultrasound data for each patient. The B-mode and strain contrasts measurements were compared using the paired samples t- test. Results The statistical analysis of a total of 45 measurements shows that the contrasts in the strain magnitude images are significantly higher than in the conventional ultrasound B-mode images (P < 0.0001). Conclusions The results indicate that ultrasound strain imaging provides better discrimination between normal brain tissue and glial tumour tissue than conventional ultrasound B-mode imaging. Ultrasound imaging of tissue strain therefore holds the potential of becoming a valuable adjunct to conventional intraoperative ultrasound imaging in brain tumour surgery

    A new acoustic coupling fluid with ability to reduce ultrasound imaging artefacts in brain tumour surgery - a phase I study

    Get PDF
    Background Anovel acoustic coupling fluid (ACF), with the potential to reduce surgically induced image artefacts during intraoperative ultrasound imaging in brain tumour surgery, has been evaluated with respect to image quality and safety in a clinical phase 1 study. Methods Fifteen patients with glioblastoma (WHO grade IV) were included. All adverse events were registered in a 6-month study period. During acquisition of 3D ultrasound image volumes, three different concentrations of the ACF and Ringer’s solution were filled into the resection cavity. The effect of ACF on the ultrasound images was rated by the operating surgeon, and by five independent neurosurgeons evaluating a pair of blinded images from all patients. Images from all patients were analysed by comparing pixel brightness in a noise-affected region and a reference region. Results The operating surgeon deemed the ACF images to have less noise than images obtained with Ringers’s solution. The blinded evaluations by the independent neurosurgeons were significantly in favour of ACF (p < 0.0001). The analyses of pixel intensities showed that the ACF images had lower amount of noise than images obtained with Ringer’s solution. No radiological sign of inflammation nor circulatory changes was found in the early postoperative MR images. Of the nine complications registered as serious events in the study period, none was deemed to be caused by the ACF. Conclusion The ultrasound (US) images obtained using ACF have significantly less noise than US images obtained with Ringer’s solution. The rate of adverse events was comparable to what has been reported for similar groups of patients.publishedVersio

    Single source 3D acquisition — A high quality and cost‐effective alternative

    No full text

    Intraoperative Ultrasound in Neurosurgery

    Full text link

    Pulsatile Dynamics of the Optic Nerve Sheath and Intracranial Pressure

    No full text
    BACKGROUND: Raised intracranial pressure (ICP) may lead to increased stiffness of the optic nerve sheath (ONS). OBJECTIVE: To develop a method for analyzing ONS dynamics from transorbital ultrasound and investigate a potential difference between patients with raised ICP vs normal ICP. METHODS: We retrospectively analyzed data from 16 patients (≤12 years old) for whom ultrasound image sequences of the ONS had been acquired from both eyes just before invasive measurement of ICP. Eight patients had an ICP ≥20 mm Hg. The transverse motion on each side of the ONS was estimated from ultrasound, and Fourier analysis was used to extract the magnitude of the displacement corresponding to the heart rate. By calculating the normalized absolute difference between the displacements on each side of the ONS, a measure of ONS deformation was obtained. This parameter was referred to as the deformability index. According to our hypothesis, because deformability is inversely related to stiffness, we expected this parameter to be lower for ICP ≥20 mm Hg compared with ICP <20 mm Hg. The one-sided Mann-Whitney U test was used for statistical comparison. RESULTS: The deformability index was significantly lower in the group with ICP ≥20 mm Hg (median value 0.11 vs 0.24; P = .002). CONCLUSION: We present a method for assessment of ONS pulsatile dynamics using transorbital ultrasound imaging. A significant difference was noted between the patient groups, indicating that deformability of the ONS may be relevant as a noninvasive marker of raised ICP. The clinical implications are promising and should be investigated in future clinical studies. ABBREVIATIONS: AUC, area under curve ICP, intracranial pressure ONS, optic nerve sheath ONSD, optic nerve sheath diameter ROC, receiver operating characteristi