252 research outputs found
Defending Mining Claims and Mineral Leases in Environmental Suits against Federal Land Managers
Recommended from our members
Anterior eye health recording.
AIMS: To survey eye care practitioners from around the world regarding their current practice for anterior eye health recording to inform guidelines on best practice. METHODS: The on-line survey examined the reported use of: word descriptions, sketching, grading scales or photographs; paper or computerised record cards and whether these were guided by proforma headings; grading scale choice, signs graded, level of precision, regional grading; and how much time eye care practitioners spent on average on anterior eye health recording. RESULTS: Eight hundred and nine eye care practitioners from across the world completed the survey. Word description (p<0.001), sketches (p=0.002) and grading scales (p<0.001) were used more for recording the anterior eye health of contact lens patients than other patients, but photography was used similarly (p=0.132). Of the respondents, 84.5% used a grading scale, 13.5% using two, with the original Efron (51.6%) and CCLRU/Brien-Holden-Vision-Institute (48.5%) being the most popular. The median features graded was 11 (range 1-23), frequency from 91.6% (bulbar hyperaemia) to 19.6% (endothelial blebs), with most practitioners grading to the nearest unit (47.4%) and just 14.7% to one decimal place. The average time taken to report anterior eye health was reported to be 6.8±5.7 min, with the maximum time available 14.0±11 min. CONCLUSIONS: Developed practice and research evidence allows best practice guidelines for anterior eye health recording to be recommended. It is recommended to: record which grading scale is used; always grade to one decimal place, record what you see live rather than based on how you intend to manage a condition; grade bulbar and limbal hyperaemia, limbal neovascularisation, conjunctival papillary redness and roughness (in white light to assess colouration with fluorescein instilled to aid visualisation of papillae/follicles), blepharitis, meibomian gland dysfunction and sketch staining (both corneal and conjunctival) at every visit. Record other anterior eye features only if they are remarkable, but indicate that the key tissue which have been examined
Investigation of radioactivity-induced backgrounds in EXO-200
The search for neutrinoless double-beta decay (0{\nu}{\beta}{\beta}) requires
extremely low background and a good understanding of their sources and their
influence on the rate in the region of parameter space relevant to the
0{\nu}{\beta}{\beta} signal. We report on studies of various {\beta}- and
{\gamma}-backgrounds in the liquid- xenon-based EXO-200 0{\nu}{\beta}{\beta}
experiment. With this work we try to better understand the location and
strength of specific background sources and compare the conclusions to
radioassay results taken before and during detector construction. Finally, we
discuss the implications of these studies for EXO-200 as well as for the
next-generation, tonne-scale nEXO detector.Comment: 9 pages, 7 figures, 3 table
The EXO-200 detector, part I: Detector design and construction
EXO-200 is an experiment designed to search for double beta decay of
Xe with a single-phase, liquid xenon detector. It uses an active mass
of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low
background time projection chamber capable of simultaneous detection of
ionization and scintillation. This paper describes the EXO-200 detector with
particular attention to the most innovative aspects of the design that revolve
around the reduction of backgrounds, the efficient use of the expensive
isotopically enriched xenon, and the optimization of the energy resolution in a
relatively large volume
A magnetically-driven piston pump for ultra-clean applications
A magnetically driven piston pump for xenon gas recirculation is presented.
The pump is designed to satisfy extreme purity and containment requirements, as
is appropriate for the recirculation of isotopically enriched xenon through the
purification system and large liquid xenon TPC of EXO-200. The pump, using
sprung polymer gaskets, is capable of pumping more than 16 standard liters per
minute (SLPM) of xenon gas with 750 torr differential pressure.Comment: 6 pages, 5 figure
Search for Neutrinoless Double-Beta Decay in Xe with EXO-200
We report on a search for neutrinoless double-beta decay of Xe with
EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background
of ~1.5 x 10^{-3} /(kg yr keV) in the region of interest. This
sets a lower limit on the half-life of the neutrinoless double-beta decay
(Xe) > 1.6 x 10 yr (90% CL),
corresponding to effective Majorana masses of less than 140-380 meV, depending
on the matrix element calculation
- …
