789 research outputs found
Probing the Composition of Primitive Solar System Materials with a Compact Laser Mass Spectrometer
To contribute to and complement our understanding of the processes governing the formation,distribution, and evolution of primitive materials throughout the solar system, it will be critical toform connections between broad remote sensing spectroscopic surveys, laboratorymeasurements of analogs and samples delivered to Earth, and in situ measurements of thesurface composition on future primitive body missions. Recently, a laboratory prototypeemploying resonance two-step laser mass spectrometry [Getty et al., 2012] has been coupledto a cryogenic sample stage to enable measurements of analog samples that are relevant tothese fundamental questions. Analyses of mineral-aromatic mixtures and meteorite powderswill be presented. Our goals are twofold: (1) to conduct laboratory studies on solar systemanalog, meteoritic, and potentially returned samples to elucidate composition, and (2) toprovide a compact but capable analytical instrument for discovery-driven in situ interrogationof surface chemistry on a future mission, such as to a Trojan asteroid, comet, or icy moon
an In Vitro Study
The poor healing potential of tendons is still a clinical problem, and the use
of Platelet Rich Plasma (PRP) was hypothesized to stimulate healing. As the
efficacy of PRPs remains unproven, platelet lysate (PL) could be an
alternative with its main advantages of storage and characterization before
use. Five different blood products were prepared from 16 male donors: human
serum, two PRPs (Arthrex, (PRP-ACP); RegenLab (PRP-BCT)), platelet concentrate
(apheresis, PC), and PL (freezing-thawing destruction of PC). Additionally,
ten commercial allogenic PLs (AlloPL) from pooled donors were tested. The
highest concentration of most growth factors was found in AlloPL, whereas the
release of growth factors lasted longer in the other products. PRP-ACP, PRP-
BCT, and PC significantly increased cell viability of human tenocyte-like
cells, whereas PC and AlloPL increased Col1A1 expression and PRP-BCT increased
Col3A1 expression. MMP-1, IL-1β, and HGF expression was significantly
increased and Scleraxis expression decreased by most blood products. COX1
expression significantly decreased by PC and AlloPL. No clear positive effects
on tendon cell biology could be shown, which might partially explain the weak
outcome results in clinical practice. Pooled PL seemed to have the most
beneficial effects and might be the future in using blood products for tendon
tissue regeneration
TCR-engineered T cells: A model of inducible TCR expression to dissect the interrelationship between two TCRs
TCR gene modified T cells for adoptive therapy simultaneously express the Tg TCR and the endogenous TCR, which might lead to mispaired TCRs with harmful unknown specificity and to a reduced function of TCR-Tg T cells. We generated dual TCR T cells in two settings in which either TCR was constitutively expressed by a retroviral promoter while the second TCR expression was regulable by a Tet-on system. Constitutively expressed TCR molecules were reduced on the cell surface depending on the induced TCR expression leading to strongly hampered function. Besides that, using fluorescence resonance energy transfer we detected mispaired TCR dimers and different pairing behaviors of individual TCR chains with a mutual influence on TCR chain expression. The loss of function and mispairing could not be avoided by changing the TCR expression level or by introduction of an additional cysteine bridge. However, in polyclonal T cells, optimized TCR formats (cysteineization, codon optimization) enhanced correct pairing and function. We conclude from our data that (i) the level of mispairing depends on the individual TCRs and is not reduced by increasing the level of one TCR, and (ii) modifications (cysteineization, codon optimization) improve correct pairing but do not completely exclude mispairing (cysteineization)
Partial Characterization of Animal Growth Inhibitors from Soybeans
The pH 4. 4 supernatant from raw (unheated) soybean meal was separated into 5 fractions on a Sephadex G-25 column in efforts to isolate the animal growth inhibitors present soybeans. Each fraction was added to the diet of growing mice and growth inhibition (GI) activity was determined by comparing their_ growth rates to g1 \u27owth rates achieved on an autoclaved soybean meal diet. Fractions I and II each contained about 50% of the GI activity, with a trace in fraction III and none in fractions IV and V. Only fraction I contained trypsin inhibitor and caused pancreatic enlargement. Fraction I was further separated into 2 fractions (Ia and Ib) on a Sephadex G-50 column. Fraction Ib contained trypsin inhibitor and caused pancreatic enlargement. Both fractions Ia and Ib contained GI activity, with most of the GI activity present in Ib. Fraction II was further separated into 2 fractions (IIa and IIb) on a phosphocellulose column eluted with a KCl gradient. Most of the GI activity was present in fraction IIb. Amino acid analysis of G-25 - II indicated all amino acids present, with the sulfur-containing amino acids, methionine and half cystine, present in only very small amount
Adopting Quality Criteria for Websites Providing Medical Information About Rare Diseases
BACKGROUND: The European Union considers diseases to be rare when they affect less than 5 in 10,000 people. It is estimated that there are between 5000 and 8000 different rare diseases. Consistent with this diversity, the quality of information available on the Web varies considerably. Thus, quality criteria for websites about rare diseases are needed. OBJECTIVE: The objective of this study was to generate a catalog of quality criteria suitable for rare diseases. METHODS: First, relevant certificates and quality recommendations for health information websites were identified through a comprehensive Web search. Second, all considered quality criteria of each certification program and catalog were examined, extracted into an overview table, and analyzed by thematic content. Finally, an interdisciplinary expert group verified the relevant quality criteria. RESULTS: We identified 9 quality certificates and criteria catalogs for health information websites with 304 single criteria items. Through this, we aggregated 163 various quality criteria, each assigned to one of the following categories: thematic, technical, service, content, and legal. Finally, a consensus about 13 quality criteria for websites offering medical information on rare diseases was determined. Of these categories, 4 (data protection concept, imprint, creation and updating date, and possibility to contact the website provider) were identified as being the most important for publishing medical information about rare diseases. CONCLUSIONS: The large number of different quality criteria appearing within a relatively small number of criteria catalogs shows that the opinion of what is important in the quality of health information differs. In addition, to define useful quality criteria for websites about rare diseases, which are an essential source of information for many patients, a trade-off is necessary between the high standard of quality criteria for health information websites in general and the limited provision of information about some rare diseases. Finally, transparently presented quality assessments can help people to find reliable information and to assess its quality
Adopting Quality Criteria for Websites Providing Medical Information About Rare Diseases
BACKGROUND: The European Union considers diseases to be rare when they affect less than 5 in 10,000 people. It is estimated that there are between 5000 and 8000 different rare diseases. Consistent with this diversity, the quality of information available on the Web varies considerably. Thus, quality criteria for websites about rare diseases are needed. OBJECTIVE: The objective of this study was to generate a catalog of quality criteria suitable for rare diseases. METHODS: First, relevant certificates and quality recommendations for health information websites were identified through a comprehensive Web search. Second, all considered quality criteria of each certification program and catalog were examined, extracted into an overview table, and analyzed by thematic content. Finally, an interdisciplinary expert group verified the relevant quality criteria. RESULTS: We identified 9 quality certificates and criteria catalogs for health information websites with 304 single criteria items. Through this, we aggregated 163 various quality criteria, each assigned to one of the following categories: thematic, technical, service, content, and legal. Finally, a consensus about 13 quality criteria for websites offering medical information on rare diseases was determined. Of these categories, 4 (data protection concept, imprint, creation and updating date, and possibility to contact the website provider) were identified as being the most important for publishing medical information about rare diseases. CONCLUSIONS: The large number of different quality criteria appearing within a relatively small number of criteria catalogs shows that the opinion of what is important in the quality of health information differs. In addition, to define useful quality criteria for websites about rare diseases, which are an essential source of information for many patients, a trade-off is necessary between the high standard of quality criteria for health information websites in general and the limited provision of information about some rare diseases. Finally, transparently presented quality assessments can help people to find reliable information and to assess its quality
Pre-cooling for endurance exercise performance in the heat: a systematic review.
PMCID: PMC3568721The electronic version of this article is the complete one and can be found online at: http://www.biomedcentral.com/1741-7015/10/166.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Endurance exercise capacity diminishes under hot environmental conditions. Time to exhaustion can be increased by lowering body temperature prior to exercise (pre-cooling). This systematic literature review synthesizes the current findings of the effects of pre-cooling on endurance exercise performance, providing guidance for clinical practice and further research
Исследование свободных колебаний ортотропных цилиндрических оболочек на основе различных моделей
Досліджуються вільні коливання ортотропних циліндричних оболонок при різних граничних умовах на краях в уточненій постановці з застосуванням теорії Міндліна–Тимошенка та на основі тривимірної теорії пружності. Для розрахунку частот використовується чисельно-аналітичний підхід, який базується на застосуванні сплайн-апроксимації, а також методу колокації, дискретної ортогоналізації разом з методом покрокового пошуку. Проведено порівняння частот циліндричних оболонок з різними граничними умовами на торцях, отриманих в рамках різних моделей.A problem of natural vibrations of orthotropic cylindrical shells under various boundary conditions of its end-faces within the framework of the Mindlin–Timoshenko theory and on the basis of 3-D elasticity theory is considered. Using the method of spline-approximation and collocation, the problems are solved by the steady-state numerical method of discrete orthogonalization with incremental search. The comparison of the frequencies of cylindrical shells with different boundary conditions on their ends within various models is performed
WEBT multiwavelength monitoring and XMM-Newton observations of BL Lacertae in 2007-2008. Unveiling different emission components
In 2007-2008 we carried out a new multiwavelength campaign of the Whole Earth
Blazar Telescope (WEBT) on BL Lacertae, involving three pointings by the
XMM-Newton satellite, to study its emission properties. The source was
monitored in the optical-to-radio bands by 37 telescopes. The brightness level
was relatively low. Some episodes of very fast variability were detected in the
optical bands. The X-ray spectra are well fitted by a power law with photon
index of about 2 and photoelectric absorption exceeding the Galactic value.
However, when taking into account the presence of a molecular cloud on the line
of sight, the data are best fitted by a double power law, implying a concave
X-ray spectrum. The spectral energy distributions (SEDs) built with
simultaneous radio-to-X-ray data at the epochs of the XMM-Newton observations
suggest that the peak of the synchrotron emission lies in the near-IR band, and
show a prominent UV excess, besides a slight soft-X-ray excess. A comparison
with the SEDs corresponding to previous observations with X-ray satellites
shows that the X-ray spectrum is extremely variable. We ascribe the UV excess
to thermal emission from the accretion disc, and the other broad-band spectral
features to the presence of two synchrotron components, with their related SSC
emission. We fit the thermal emission with a black body law and the non-thermal
components by means of a helical jet model. The fit indicates a disc
temperature greater than 20000 K and a luminosity greater than 6 x 10^44 erg/s.Comment: 11 pages, 7 figures, accepted for publication in A&
- …
