2,631 research outputs found
"Tjedan fizike" u knjižnici
SREDIŠNJA KNJIÝNICA ZA FIZIKU (SKF) povodom Svjetske godine
fizike (World Year of Physics 2005.) u studenom (7. 11. – 12.
11. 2005.) pridružila se zajedničkoj organizaciji u sklopu Tjedna fizike, koje je koordiniralo Hrvatsko fizikalno društvo (HFD). SKF je
u svojim prostorima priredila izložbu s ostalim pratećim manifestacijama
(predavanjima, prezentacijama, projekcijama filmova, promocijama
knjiga, danima otvorenih vrata, organiziranim posjetima
uèenika srednjih i osmogodišnjih škola i sl.)
Mechanical identification of layer-specific properties of mouse carotid arteries using 3D-DIC and a hyperelastic anisotropic constitutive model
The role of mechanics is known to be of primary order in many arterial
diseases; however, determining mechanical properties of arteries remains a
challenge. This paper discusses the identifiability of the passive mechanical
properties of a mouse carotid artery, taking into account the orientation of
collagen fibres in the medial and adventitial layers. On the basis of 3D
digital image correlation measurements of the surface strain during an
inflation/extension test, an inverse identification method is set up. It
involves a 3D finite element mechanical model of the mechanical test and an
optimisation algorithm. A two-layer constitutive model derived from the
Holzapfel model is used, with five and then seven parameters. The
five-parameter model is successfully identified providing layer-specific fibre
angles. The seven-parameter model is over parameterised, yet it is shown that
additional data from a simple tension test make the identification of refined
layer-specific data reliable.Comment: PB-CMBBE-15.pd
Avviste asylsøkere og ventemottaksordningen. Mellom passiv tvang og aktiv returassistanse
-Rapporten fokuserer på ventemottaksordningen,ordningens rolle i returarbeidet, og hvordan den samhandler med andre returfremmende tiltak som iverksettes av norske myndigheter. Rapporten baserer seg på kvalitativt og kvantitativt datamateriale som ble samlet inn høsten 2009 og våren 2010
Accuracy of low-dose computed tomography coronary angiography using prospective electrocardiogram-triggering: first clinical experience
AIMS: To evaluate the accuracy of low-dose computed tomography coronary angiography (CTCA) using prospective ECG-triggering for the assessment of coronary artery disease (CAD). METHODS AND RESULTS: A total of 30 patients (19 males, 11 females, mean age 58.8 +/- 9.9 years) underwent low-dose CTCA and invasive coronary angiography (CA) [median 2 days (0, 41)]. Before CT scanning, intravenous beta-blocker was administered in 18 of 30 patients as heart rate (HR) was >65 b.p.m., achieving a mean HR of 55.7 +/- 7.9 b.p.m. CAD was defined as coronary artery narrowing > or =50%, using CA as standard of reference. The estimated mean effective radiation dose was 2.1 +/- 0.7 mSv (range: 1.0-3.3), yielding 96.0% (383/399) of evaluable segments. On an intention-to-diagnose-base, all non-evaluative segments were included in the analysis. Vessels with a non-evaluative segment and no further finding were censored as false positive. Patient-based analysis revealed sensitivity, specificity, positive predictive value, and negative predictive value of 100, 83.3, 90.0, and 100%, respectively. The respective values per vessel were 100, 88.9, 85.7, and 100%, respectively. CONCLUSION: Prospective ECG-triggering allows low-dose CTCA and provides high diagnostic accuracy in the assessment of CAD in patients with stable sinus rhythm and a low heart rat
Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating
Aims To determine diagnostic accuracy, effective radiation dose, and potential value of computed tomography coronary angiography (CTCA) for hybrid imaging with single-photon emission computed tomography (SPECT) comparing prospective electrocardiogram (ECG)-triggering vs. retrospective ECG-gating. Methods and results Two hundred patients underwent standard myocardial stress/rest- SPECT perfusion imaging, which served as standard of reference. One hundred consecutive patients underwent 64-slice CTCA using prospective ECG-gating, and were compared with 100 patients who had previously undergone CTCA using retrospective ECG-gating. For predicting ischaemia, CTCA with prospective ECG-triggering and a stenosis cut-off >50% had a per-vessel sensitivity, specificity, negative, and positive predictive value of 100, 84, 100, and 30%; respective values for CTCA with retrospective ECG-gating were similar (P = n.s.): 86, 83, 98, and 33%. Combining CTCA with stress-only SPECT revealed 100% clinical agreement with regard to perfusion defects, and provided additional information in half the patients on preclinical coronary findings. Effective radiation dose was 2.2 ± 0.7 mSv for CTCA with prospective ECG-triggering, and 19.7 ± 4.2 mSv with retrospective ECG-gating (P < 0.001) (5.4 ± 0.8 vs. 24.1 ± 4.3 mSv for hybrid imaging). Conclusion Prospective ECG-triggering for CTCA reduces radiation dose by almost 90% without affecting diagnostic performance. Combined imaging with stress-only SPECT is an attractive alternative to standard stress/rest-SPECT for evaluation of coronary artery disease, offering additional information on preclinical atherosclerosi
Expression of Zm13, a pollen specific maize protein, in Escherichia coli reveals IgE-binding capacity and allergenic potential
AbstractPlant proteins belong to the most frequent elicitors of type I allergic symptoms in industrialized countries. Several relevant plant allergens have been found to be either specifically expressed or highly upregulated in mature pollen. The cDNA coding for a pollen specific maize protein, Zm13, shows significant sequence homology with a number of pollen or anther specific proteins from monocot and dicot plants as well as with recently described allergens from olive and rye grass. To test whether the Zm13 protein might possess IgE-binding capacity, Zm13 was expressed in E coli. The coding region of Zm13 was PCR amplified from a genomic clone and expressed as as a glutathione-S-transferase fusion protein. The recombinant Zm13 fusion protein bound a Zm13 specific rabbit antiserum and reacted with serum IgE from grass pollen allergic patients indicating that Zm13 and homologous proteins represent a family of conserved plant allergens
Coronary CT angiography and myocardial perfusion imaging to detect flow-limiting stenoses: a potential gatekeeper for coronary revascularization?
Aims To evaluate the diagnostic accuracy of a combined non-invasive assessment of coronary artery disease with coronary CT angiography (CTA) and myocardial perfusion imaging (MPI) for the detection of flow-limiting coronary stenoses and its potential as a gatekeeper for invasive examination and treatment. Methods and results In 78 patients (mean age 65 ± 9 years) referred for coronary angiography (CA), additional CTA and MPI (using single-photon emission-computed tomography) were performed and the findings not communicated. Detection of flow-limiting stenoses (justifying revascularization) by the combination of CTA and MPI (CTA/MPI) was compared with the combination of quantitative coronary angiography (QCA) plus MPI (QCA/MPI), which served as standard of reference. The findings of both combinations were related to the treatment strategy (revascularization vs. medical treatment) chosen in the catheterization laboratory based on the CA findings. Sensitivity, specificity, positive and negative predictive value, and accuracy of CTA/MPI for the detection of flow-limiting coronary stenoses were 100% each. More than half of revascularization procedures (21/40, 53%) was performed in patients without flow-limiting stenoses and 76% (47/62) of revascularized vessels were not associated with ischaemia on MPI. Conclusion The combined non-invasive approach CTA/MPI has an excellent accuracy to detect flow-limiting coronary stenoses compared with QCA/MPI and its use as a gatekeeper appears to make a substantial part of revascularization procedures redundan
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.
Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating
AIMS: To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). METHODS AND RESULTS: Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). CONCLUSION: This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.
Nuclear myocardial perfusion imaging with a cadmium-zinc-telluride detector technique: optimized protocol for scan time reduction
We aimed at establishing the optimal scan time for nuclear myocardial perfusion imaging (MPI) on an ultrafast cardiac gamma-camera using a novel cadmium-zinc-telluride (CZT) solid-state detector technology. METHODS: Twenty patients (17 male; BMI range, 21.7-35.5 kg/m(2)) underwent 1-d (99m)Tc-tetrofosmin adenosine stress and rest MPI protocols, each with a 15-min acquisition on a standard dual-detector SPECT camera. All scans were immediately repeated on an ultrafast CZT camera over a 6-min acquisition time and reconstructed from list-mode raw data to obtain scan durations of 1 min, 2 min, etc., up to a maximum of 6 min. For each of the scan durations, the segmental tracer uptake value (percentage of maximum myocardial uptake) from the CZT camera was compared by intraclass correlation with standard SPECT camera data using a 20-segment model, and clinical agreement was assessed per coronary territory. Scan durations above which no further relevant improvement in uptake correlation was found were defined as minimal required scan times, for which Bland-Altman limits of agreement were calculated. RESULTS: Minimal required scan times were 3 min for low dose (r = 0.81; P < 0.001; Bland-Altman, -11.4% to 12.2%) and 2 min for high dose (r = 0.80; P < 0.001; Bland-Altman, -7.6% to 12.9%), yielding a clinical agreement of 95% and 97%, respectively. CONCLUSION: We have established the minimal scan time for a CZT solid-state detector system, which allows 1-d stress/rest MPI with a substantially reduced acquisition time resulting in excellent agreement with regard to uptake and clinical findings, compared with MPI from a standard dual-head SPECT gamma-camera
- …
