764 research outputs found

    Measuring the magnetic axis alignment during solenoids working

    Get PDF
    A method for monitoring the misalignment of the magnetic axis in solenoids is proposed. This method requires only a few measurements of the magnetic field at fixed positions inside the magnet aperture, and thus overcomes the main drawback of sturdy moving mechanics of other Hall sensor-based methods. Conversely to state-of-the-art axis determination, the proposed method can be applied also during magnet operations, when the axis region and almost the whole remaining magnet aperture are not accessible. Moreover, only a few measurements of the magnetic field at fixed positions inside the magnet aperture are required: thus a slow process such as the mapping of the whole aperture of a magnet by means of moving stages is not necessary. The mathematical formulation of the method is explained, and a case study on a model of a multi–layer solenoid is presented. For this case study, the uncertainty is assessed and the optimal placement of the Hall transducers is derived

    Smooth pursuits decrease balance control during locomotion in young and older healthy females.

    Get PDF
    Dynamic balance control-characterised as movement of the trunk and lower limbs-was assessed during fixation of a fixed target, smooth pursuits and saccadic eye movements in ten young (22.9 ± 1.5 years) and ten older (72.1 ± 8.2 years) healthy females walking overground. Participants were presented with visual stimuli to initiate eye movements, and posture and gaze were assessed with motion analysis and eye tracking equipment. The results showed an increase in medial/lateral (ML) trunk movement (C7: p = 0.012; sacrum: p = 0.009) and step-width variability (p = 0.052) during smooth pursuits compared to a fixed target, with no changes for saccades compared to a fixed target. The elders demonstrated greater ML trunk movement (sacrum: p = 0.037) and step-width variability (p = 0.037) than the younger adults throughout, although this did not interact with the eye movements. The findings showed that smooth pursuits decreased balance control in young and older adults similarly, which was likely a consequence of more complicated retinal flow. Since healthy elders are typically already at a postural disadvantage, further decreases in balance caused by smooth pursuits are undesirable

    Conceptual design of electron beam diagnostics for high brightness plasma accelerator

    Get PDF
    A design study of the diagnostics of a high brightness linac, based on X-band structures, and a plasma accelerator stage, has been delivered in the framework of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual design of the proposed diagnostics, using state of the art systems and new and under development devices. Single shot measurements are preferable for plasma accelerated beams, including emittance, while μ\mum level and fs scale beam size and bunch length respectively are requested. The needed to separate the driver pulse (both laser or beam) from the witness accelerated bunch imposes additional constrains for the diagnostics. We plan to use betatron radiation for the emittance measurement just at the end of the plasma booster, while other single-shot methods must be proven before to be implemented. Longitudinal measurements, being in any case not trivial for the fs level bunch length, seem to have already a wider range of possibilities

    Epitaxial growth of SrTiO3 films on cube-textured Cu-clad substrates by PLD at low temperature under reducing atmosphere

    Get PDF
    The growth of epitaxial {001} SrTiO3 (STO) on low-cost cube-textured Cu-based clad substrate at low temperature was carried out by means of pulsed laser deposition (PLD). STO film was deposited in one step under a reducing atmosphere (5% H2 and 95% Ar mixture) to prevent the oxidation of the metal surface. The optimization of PLD parameters leads to a sharpest biaxial texture at a temperature as low as 500 °C and a thickness of 500 nm with a (100) STO layer. The upper limit of highly textured STO thickness was also investigated. The maximum thickness which retains the best quality {001} texture is 800 nm, since the texture is preserved not only through the layer but also on the surface. Atomic force microscopy (AFM) and scanning electron microscopy (SEM) measurements showed that STO films are continuous, dense, and smooth with very low roughness (between 5 and 7 nm). This paper describes the development of STO layer by means of PLD in absence of oxygen throughout the process, suggesting an alternative and effective method for growing highly {001} textured STO layer on low-cost metal substrates

    Delivery status of the ELI-NP gamma beam system

    Get PDF
    International audienceThe ELI-NP GBS is a high intensity and monochromatic gamma source under construction in Magurele (Romania). The design and construction of the Gamma Beam System complex as well as the integration of the technical plants and the commissioning of the overall facility, was awarded to the Eurogammas Consortium in March 2014. The delivery of the facility has been planned in for 4 stages and the first one was fulfilled in October 31st 2015. The engineering aspects related to the delivery stage 1 are presented

    Impact of a Dexmedetomidine Intravenous Infusion in Septic Dogs: Preliminary Study

    Get PDF
    Simple Summary Sepsis is a widespread concern in human and veterinary medicine. Over the past several years, numerous strategies have been implemented to try to combat it; however, mortality remains high in all species. The use of dexmedetomidine, an alpha-two agonist drug with sedative and analgesic properties, is gaining popularity as a synergistic treatment strategy in the management of sepsis, thanks to its anti-apoptotic and neuroprotective properties and its ability to preserve hemodynamic function. We therefore hypothesized that a continuous rate infusion of dexmedetomidine in septic patients, undergoing emergency surgery, could decrease the requirement for vasopressors. The results of this study show that an infusion of 1 mcg/kg/h of dexmedetomidine decreases intraoperative vasopressor use and improves 28-day mortality. However, given the small sample size, a larger prospective study should be undertaken to confirm these findings.Abstract The purpose of this study was to determine if a continuous rate infusion (CRI) of dexmedetomidine decreases vasopressor requirements in septic dogs undergoing surgery. Vital parameters, sequential organ failure assessment (SOFA) score, vasopressor requirement, and 28-day mortality were recorded. Dogs were randomly divided into two groups: a dexmedetomidine (DEX) (1 mcg/kg/h) group and a control group (NaCl), which received an equivalent CRI of NaCl. Dogs were premedicated with fentanyl 5 mcg/kg IV, induced with propofol, and maintained with sevoflurane and a variable rate fentanyl infusion. DEX or NaCl infusions were started 10 min prior to induction. Fluid-responsive hypotensive patients received repeated Ringer's lactate boluses (2 mL/kg) until stable or they were no longer fluid-responsive. Patients that remained hypotensive following fluid boluses received norepinephrine at a starting dose of 0.05 mcg/kg/min, with increases of 0.05 mcg/kg/min. Rescue adrenaline boluses were administered (0.001 mg/kg) if normotension was not achieved within 30 min of starting norepinephrine. The NaCl group received a significantly higher dose of norepinephrine (0.8, 0.4-2 mcg/kg/min) than the DEX group (0.12, 0-0.86 mcg/kg/min). Mortality was statistically lower in the DEX group (1/10) vs. the NaCl group (5/6). Results of this study suggest that a 1 mcg/kg/h CRI of dexmedetomidine decreases the demand for intraoperative vasopressors and may improve survival in septic dogs
    corecore