318 research outputs found
Comparison of serious inhaler technique errors made by device-naïve patients using three different dry powder inhalers: a randomised, crossover, open-label study
Background: Serious inhaler technique errors can impair drug delivery to the lungs. This randomised, crossover, open-label study evaluated the proportion of patients making predefined serious errors with Pulmojet compared with Diskus and Turbohaler dry powder inhalers. Methods: Patients ≥18 years old with asthma and/or COPD who were current users of an inhaler but naïve to the study devices were assigned to inhaler technique assessment on Pulmojet and either Diskus or Turbohaler in a randomised order. Patients inhaled through empty devices after reading the patient information leaflet. If serious errors potentially affecting dose delivery were recorded, they repeated the inhalations after watching a training video. Inhaler technique was assessed by a trained nurse observer and an electronic inhalation profile recorder. Results: Baseline patient characteristics were similar between randomisation arms for the Pulmojet-Diskus (n = 277) and Pulmojet-Turbohaler (n = 144) comparisons. Non-inferiority in the proportions of patients recording no nurse-observed serious errors was demonstrated for both Pulmojet versus Diskus, and Pulmojet versus Turbohaler; therefore, superiority was tested. Patients were significantly less likely to make ≥1 nurse-observed serious errors using Pulmojet compared with Diskus (odds ratio, 0.31; 95 % CI, 0.19–0.51) or Pulmojet compared with Turbohaler (0.23; 0.12–0.44) after reading the patient information leaflet with additional video instruction, if required. Conclusions These results suggest Pulmojet is easier to learn to use correctly than the Turbohaler or Diskus for current inhaler users switching to a new dry powder inhaler
Evaluation of inhaler technique and achievement and maintenance of mastery of budesonide/formoterol Spiromax® compared with budesonide/formoterol Turbuhaler® in adult patients with asthma: the Easy Low Instruction Over Time (ELIOT) study
Background: Incorrect inhaler technique is a common cause of poor asthma control. This two-phase pragmatic study evaluated inhaler technique mastery and maintenance of mastery with DuoResp® (budesonide-formoterol [BF]) Spiromax® compared with Symbicort® (BF) Turbuhaler® in patients with asthma who were receiving inhaled corticosteroids/long-acting β2-agonists. Methods: In the initial cross-sectional phase, patients were randomized to a 6-step training protocol with empty Spiromax and Turbuhaler devices. Patients initially demonstrating ≥1 error with their current device, and then achieving mastery with both Spiromax and Turbuhaler (absence of healthcare professional [HCP]-observed errors), were eligible for the longitudinal phase. In the longitudinal phase, patients were randomized to BF Spiromax or BF Turbuhaler. Co-primary endpoints were the proportions of patients achieving device mastery after three training steps and maintaining device mastery (defined as the absence of HCP-observed errors after 12 weeks of use). Secondary endpoints included device preference, handling error frequency, asthma control, and safety. Exploratory endpoints included assessment of device mastery by an independent external expert reviewing video recordings of a subset of patients. Results: Four hundred ninety-three patients participated in the cross-sectional phase, and 395 patients in the longitudinal phase. In the cross-sectional phase, more patients achieved device mastery after three training steps with Spiromax (94%) versus Turbuhaler (87%) (odds ratio [OR] 3.77 [95% confidence interval (CI) 2.05–6.95], p < 0.001). Longitudinal phase data indicated that the odds of maintaining inhaler mastery at 12 weeks were not statistically significantly different (OR 1.26 [95% CI 0.80–1.98], p = 0.316). Asthma control improved in both groups with no significant difference between groups (OR 0.11 [95% CI -0.09–0.30]). An exploratory analysis indicated that the odds of maintaining independent expert-verified device mastery were significantly higher for patients using Spiromax versus Turbuhaler (OR 2.11 [95% CI 1.25–3.54]). Conclusions: In the cross-sectional phase, a significantly greater proportion of patients using Spiromax versus Turbuhaler achieved device mastery; in the longitudinal phase, the proportion of patients maintaining device mastery with Spiromax versus Turbuhaler was similar. An exploratory independent expert-verified analysis found Spiromax was associated with higher levels of device mastery after 12 weeks. Asthma control was improved by treatment with both BF Spiromax and BF Turbuhaler
Serum interleukin-5 levels are elevated in mild and moderate persistent asthma irrespective of regular inhaled glucocorticoid therapy
BACKGROUND: Interleukin-5 (IL-5) is thought to play a pivotal role in the pathogenesis of asthma. High levels of circulating IL-5 have been documented in acute asthma. However, serum IL-5 levels in mild to moderate asthmatics and the influence of regular use of inhaled glucocorticoids, is not known. METHODS: Fifty-six asthmatics and 56 age and sex matched controls were recruited prospectively from an outpatient department. Information on asthma severity and treatment was gathered by a questionnaire. Serum IL-5, total IgE and specific IgE levels were measured in a blinded fashion. RESULTS: There were 32 atopic and 24 non-atopic mild-to-moderate asthmatics. The median serum IL-5 levels in atopic asthmatics (9.5 pg/ml) and in non-atopic asthmatics (8.1 pg/ml) were significantly higher than in normal controls (4.4 pg/ml, both p < 0.003). However, median serum IL-5 levels in atopic and non-atopic asthmatics were not significantly different. The median serum IL-5 level was insignificantly higher in fourteen moderate persistent asthmatics (10.6 pg/ml) compared to forty-two mild persistent asthmatics (7.3 pg/ml) (p = 0.13). The median serum IL-5 levels in asthmatics using regular inhaled steroids (7.8 pg/ml) was not significantly different from those not using inhaled steroids (10.2 pg/ml). Furthermore, serum total IgE levels and eosinophil counts were not significantly different in those using versus those not using inhaled glucocorticoids. CONCLUSION: Serum IL-5 levels are elevated in mild and moderate persistent atopic and non-atopic asthmatics. Regular use of inhaled glucocorticoids may not abrogate the systemic Th2 type of inflammatory response in mild-moderate persistent asthma
Major basic protein, but not eosinophil cationic protein or eosinophil protein X, is related to atopy in cystic fibrosis
Dry-powder inhalers in patients with persistent airflow limitation: usability and preference
Tolerance and rebound with zafirlukast in patients with persistent asthma
<p>Abstract</p> <p>Background</p> <p>The potential for tolerance to develop to zafirlukast, a cysteinyl leukotriene (CysLT) receptor antagonist (LRA) in persistent asthma, has not been specifically examined.</p> <p>Objective</p> <p>To look for any evidence of tolerance and potential for short-term clinical worsening on LRA withdrawal. Outcome measures included changes in; airway hyperresponsiveness to inhaled methacholine (PD<sub>20</sub>FEV<sub>1</sub>), daily symptoms and peak expiratory flows (PEF), sputum and blood cell profiles, sputum CysLT and prostaglandin (PG)E<sub>2 </sub>and exhaled nitric oxide (eNO) levels.</p> <p>Methods</p> <p>A double blind, placebo-controlled study of zafirlukast, 20 mg twice daily over 12 weeks in 21 asthmatics taking β<sub>2</sub>-agonists only (Group I), and 24 subjects treated with ICS (Group II).</p> <p>Results</p> <p>In Group I, zafirlukast significantly improved morning PEF and FEV<sub>1</sub>compared to placebo (p < 0.01), and reduced morning waking with asthma from baseline after two weeks (p < 0.05). Similarly in Group II, FEV<sub>1 </sub>improved compared to placebo (p < 0.05), and there were early within-treatment group improvements in morning PEF, β<sub>2</sub>-agonist use and asthma severity scores (p < 0.05). However, most improvements with zafirlukast in Group I and to a lesser extent in Group II deteriorated toward baseline values over 12 weeks. In both groups, one week following zafirlukast withdrawal there were significant deteriorations in morning and evening PEFs and FEV<sub>1 </sub>compared with placebo (p ≤ 0.05) and increased nocturnal awakenings in Group II (p < 0.05). There were no changes in PD<sub>20</sub>FEV<sub>1</sub>, sputum CysLT concentrations or exhaled nitric oxide (eNO) levels. However, blood neutrophils significantly increased in both groups following zafirlukast withdrawal compared to placebo (p = 0.007).</p> <p>Conclusion</p> <p>Tolerance appears to develop to zafirlukast and there is rebound clinical deterioration on drug withdrawal, accompanied by a blood neutrophilia.</p
Albuterol enantiomer levels, lung function and QTc interval in patients with acute severe asthma and COPD in the emergency department
Differential regulation of neurotrophin expression in human bronchial smooth muscle cells
BACKGROUND: Human bronchial smooth muscle cells (HBSMC) may regulate airway inflammation by secreting cytokines, chemokines and growth factors. The neurotrophins, including nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF) and neurotrophin-3 (NT-3), have been shown to be elevated during airway inflammation and evoke airway hyperresponsiveness. We studied if HBSMC may be a source of NGF, BDNF and NT-3, and if so, how inflammatory cytokines may influence their production. METHODS: Basal and cytokine (IL-1β, IFN-γ, IL-4)-stimulated neurotrophin expression in HBSMC cultured in vitro was quantified. The mRNA expression was quantified by real-time RT-PCR and the protein secretion into the cell culture medium by ELISA. RESULTS: We observed a constitutive NGF, BDNF and NT-3 expression. IL-1β stimulated a transient increase of NGF, while the increase of BDNF had a later onset and was more sustained. COX-inhibitors (indomethacin and NS-398) markedly decreased IL-1β-stimulated secretion of BDNF, but not IL-1β-stimulated NGF secretion. IFN-γ increased NGF expression, down-regulated BDNF expression and synergistically enhanced IL-1β-stimulated NGF expression. In contrast, IL-4 had no effect on basal NGF and BDNF expression, but decreased IL-1β-stimulated NGF expression. NT-3 was not altered by the tested cytokines. CONCLUSION: Taken together, our data indicate that, in addition to the contractile capacity, HBSMC can express NGF, BDNF and NT-3. The expression of these neurotrophins may be differently regulated by inflammatory cytokines, suggesting a dynamic interplay that might have a potential role in airway inflammation
Correlating corneal arcus with atherosclerosis in familial hypercholesterolemia
Abstract Background A relationship between corneal arcus and atherosclerosis has long been suspected but is controversial. The homozygous familial hypercholesterolemia patients in this study present a unique opportunity to assess this issue. They have both advanced atherosclerosis and corneal arcus. Methods This is a cross-sectional study of 17 patients homozygous for familial hypercholesterolemia presenting to the Clinical Center of the National Institutes of Health. Plasma lipoproteins, circumferential extent of arcus, thoracic aorta and coronary calcific atherosclerosis score, and Achilles tendon width were measured at the National Institutes of Health. Results Patients with corneal arcus had higher scores for calcific atherosclerosis (mean 2865 compared to 412), cholesterol-year score (mean 11830 mg-yr/dl compared to 5707 mg-yr/dl), and Achilles tendon width (mean 2.54 cm compared to 1.41 cm) than those without. Corneal arcus and Achilles tendon width were strongly correlated and predictive of each other. Although corneal arcus was correlated with calcific atherosclerosis (r = 0.67; p = 0.004), it was not as highly correlated as was the Achilles tendon width (r = 0.855; p Conclusion Corneal arcus reflects widespread tissue lipid deposition and is correlated with both calcific atherosclerosis and xanthomatosis in these patients. Patients with more severe arcus tend to have more severe calcific atherosclerosis. Corneal arcus is not as good an indicator of calcific atherosclerosis as Achilles tendon thickness, but its presence suggests increased atherosclerosis in these hypercholesterolemic patients.</p
- …
