664 research outputs found
NIKEL: Electronics and data acquisition for kilopixels kinetic inductance camera
A prototype of digital frequency multiplexing electronics allowing the real
time monitoring of microwave kinetic inductance detector (MKIDs) arrays for
mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it
can monitor simultaneously 400 pixels over a 500 MHz bandwidth and requires
only two coaxial cables for instrumenting such a large array. The chosen
solution and the performances achieved are presented in this paper.Comment: 21 pages, 14 figure
Captive reptile mortality rates in the home and implications for the wildlife trade
The trade in wildlife and keeping of exotic pets is subject to varying levels of national and international regulation and is a topic often attracting controversy. Reptiles are popular exotic pets and comprise a substantial component of the live animal trade. High mortality of traded animals raises welfare concerns, and also has implications for conservation if collection from the wild is required to meet demand. Mortality of reptiles can occur at any stage of the trade chain from collector to consumer. However, there is limited information on mortality rates of reptiles across trade chains, particularly amongst final consumers in the home. We investigated mortality rates of reptiles amongst consumers using a specialised technique for asking sensitive questions, additive Randomised Response Technique (aRRT), as well as direct questioning (DQ). Overall, 3.6% of snakes, chelonians and lizards died within one year of acquisition. Boas and pythons had the lowest reported mortality rates of 1.9% and chameleons had the highest at 28.2%. More than 97% of snakes, 87% of lizards and 69% of chelonians acquired by respondents over five years were reported to be captive bred and results suggest that mortality rates may be lowest for captive bred individuals. Estimates of mortality from aRRT and DQ did not differ significantly which is in line with our findings that respondents did not find questions about reptile mortality to be sensitive. This research suggests that captive reptile mortality in the home is rather low, and identifies those taxa where further effort could be made to reduce mortality rate
Global and regional brain metabolic scaling and its functional consequences
Background: Information processing in the brain requires large amounts of
metabolic energy, the spatial distribution of which is highly heterogeneous
reflecting complex activity patterns in the mammalian brain.
Results: Here, it is found based on empirical data that, despite this
heterogeneity, the volume-specific cerebral glucose metabolic rate of many
different brain structures scales with brain volume with almost the same
exponent around -0.15. The exception is white matter, the metabolism of which
seems to scale with a standard specific exponent -1/4. The scaling exponents
for the total oxygen and glucose consumptions in the brain in relation to its
volume are identical and equal to , which is significantly larger
than the exponents 3/4 and 2/3 suggested for whole body basal metabolism on
body mass.
Conclusions: These findings show explicitly that in mammals (i)
volume-specific scaling exponents of the cerebral energy expenditure in
different brain parts are approximately constant (except brain stem
structures), and (ii) the total cerebral metabolic exponent against brain
volume is greater than the much-cited Kleiber's 3/4 exponent. The
neurophysiological factors that might account for the regional uniformity of
the exponents and for the excessive scaling of the total brain metabolism are
discussed, along with the relationship between brain metabolic scaling and
computation.Comment: Brain metabolism scales with its mass well above 3/4 exponen
Organic electrode coatings for next-generation neural interfaces
Traditional neuronal interfaces utilize metallic electrodes which in recent years have reached a plateau in terms of the ability to provide safe stimulation at high resolution or rather with high densities of microelectrodes with improved spatial selectivity. To achieve higher resolution it has become clear that reducing the size of electrodes is required to enable higher electrode counts from the implant device. The limitations of interfacing electrodes including low charge injection limits, mechanical mismatch and foreign body response can be addressed through the use of organic electrode coatings which typically provide a softer, more roughened surface to enable both improved charge transfer and lower mechanical mismatch with neural tissue. Coating electrodes with conductive polymers or carbon nanotubes offers a substantial increase in charge transfer area compared to conventional platinum electrodes. These organic conductors provide safe electrical stimulation of tissue while avoiding undesirable chemical reactions and cell damage. However, the mechanical properties of conductive polymers are not ideal, as they are quite brittle. Hydrogel polymers present a versatile coating option for electrodes as they can be chemically modified to provide a soft and conductive scaffold. However, the in vivo chronic inflammatory response of these conductive hydrogels remains unknown. A more recent approach proposes tissue engineering the electrode interface through the use of encapsulated neurons within hydrogel coatings. This approach may provide a method for activating tissue at the cellular scale, however, several technological challenges must be addressed to demonstrate feasibility of this innovative idea. The review focuses on the various organic coatings which have been investigated to improve neural interface electrodes
CVD-Enabled Graphene Manufacture and Technology.
Integrated manufacturing is arguably the most challenging task in the development of technology based on graphene and other 2D materials, particularly with regard to the industrial demand for “electronic-grade” large-area films. In order to control the structure and properties of these materials at the monolayer level, their nucleation, growth and interfacing needs to be understood to a level of unprecedented detail compared to existing thin film or bulk materials. Chemical vapor deposition (CVD) has emerged as the most versatile and promising technique to develop graphene and 2D material films into industrial device materials and this Perspective outlines recent progress, trends, and emerging CVD processing pathways. A key focus is the emerging understanding of the underlying growth mechanisms, in particular on the role of the required catalytic growth substrate, which brings together the latest progress in the fields of heterogeneous catalysis and classic crystal/thin-film growth.Funding from the ERC (Grant No. 279342, InSituNANO) and EPSRC (Grant No. EP/K016636/1, GRAPHTED) is acknowledged. R.S.W. acknowledges a research fellowship from St. John’s College, Cambridge.This is the final version of the article. It first appeared from ACS via http://dx.doi.org/10.1021/acs.jpclett.5b0105
Plant establishment on unirrigated green roof modules in a subtropical climate
BACKGROUND AND AIMS: The application of green roof technology has become more common in the central, northwestern and eastern USA, and is now being employed across the southern USA as well. However, there is little research in the literature that evaluated plant survival on unirrigated green roofs in subtropical climates that experience frequent drought and heat stress. Here, we summarize the results of a study of plant establishment on a modular green roof in south-central Texas. METHODOLOGY: Fifteen plant species were field tested in 11.4-cm-deep green roof modules on a four-storey building in College Station, Texas, with irrigation limited to the first several weeks of establishment. Climate data, plant growth and species survival were measured over three growing seasons. PRINCIPAL RESULTS: Four species survived growing seasons without any losses: Graptopetalum paraguayense, Malephora lutea, Manfreda maculosa and Phemeranthus calycinus. Six species experienced varying levels of mortality: Bulbine frutescens, Delosperma cooperi, Lampranthus spectabilis, Sedum kamtschaticum, Sedum mexicanum and Nassella tenuissima. Five species had no survivors: Dichondra argentea, Stemodia lanata, Myoporum parvifolium, Sedum moranense and Sedum tetractinum. CONCLUSIONS: The establishment and survival of several plant species without any mortality suggests that irrigation limited to the first few weeks after planting may be an effective approach on green roofs in spite of the more challenging climatic conditions in the southern USA. Since the climate in south-central Texas had been consistently drier and warmer than normal during the study period, longer-term research on these species is recommended to expand knowledge of establishment requirements for these species under a wider range of conditions, including wetter than normal years
Bioaccumulation and ecotoxicity of carbon nanotubes
Carbon nanotubes (CNT) have numerous industrial applications and may be released to the environment. In the aquatic environment, pristine or functionalized CNT have different dispersion behavior, potentially leading to different risks of exposure along the water column. Data included in this review indicate that CNT do not cross biological barriers readily. When internalized, only a minimal fraction of CNT translocate into organism body compartments. The reported CNT toxicity depends on exposure conditions, model organism, CNT-type, dispersion state and concentration. In the ecotoxicological tests, the aquatic organisms were generally found to be more sensitive than terrestrial organisms. Invertebrates were more sensitive than vertebrates. Single-walled CNT were found to be more toxic than double-/multi-walled CNT. Generally, the effect concentrations documented in literature were above current modeled average environmental concentrations. Measurement data are needed for estimation of environmental no-effect concentrations. Future studies with benchmark materials are needed to generate comparable results. Studies have to include better characterization of the starting materials, of the dispersions and of the biological fate, to obtain better knowledge of the exposure/effect relationships
Vanadium Dioxide Cathodes for High-Rate Photo-Rechargeable Zinc-Ion Batteries
Photovoltaics are an important source of renewable energy, but due the intermittent nature of insolation, solar cells usually need to be connected to rechargeable batteries, electrochemical capacitors or other energy storage devices, which adds to the complexity and cost of these systems. In this work, we report a cathode design for photo-rechargeable zinc-ion batteries (photo-ZIBs) that is inherently capable of harvesting sunlight to recharge without the need for external solar cells. The proposed photocathodes comprising a composite of vanadium dioxide nanorods and reduced graphene oxide, are engineered to provide the necessary charge separation and storage for photocharging under illumination. The photo-ZIBs achieve gravimetric capacities of ~ 282 mAh g-1 in the dark and ~ 315 mAh g-1 under illumination, at 200 mA g-1, demonstrating the use of light not only to charge the deceives, but additionally to enhance their capacity. The photo-ZIBs also demonstrate enhanced high-rate capabilities under illumination, as well as a capacity retention of ∼ 90% over 1000 cycles. The proposed photo-ZIBs demonstrate a promising new technology for addressing energy poverty, due to their high performance and inherent cost-efficiency and safety.Newton International Fellowship-Royal Society (UK) grant NIF∖R1∖181656
ERC Consolidator grant MIGHTY - 866005
EPSRC Graphene CDT EP/L016087/
Sensory substitution information informs locomotor adjustments when walking through apertures
The study assessed the ability of the central nervous system (CNS) to use echoic information from sensory substitution devices (SSDs) to rotate the shoulders and safely pass through apertures of different width. Ten visually normal participants performed this task with full vision, or blindfolded using an SSD to obtain information regarding the width of an aperture created by two parallel panels. Two SSDs were tested. Participants passed through apertures of +0%, +18%, +35%, and +70% of measured body width. Kinematic indices recorded movement time, shoulder rotation, average walking velocity across the trial, peak walking velocities before crossing, after crossing and throughout a whole trial. Analyses showed participants used SSD information to regulate shoulder rotation, with greater rotation associated with narrower apertures. Rotations made using an SSD were greater compared to vision, movement times were longer, average walking velocity lower and peak velocities before crossing, after crossing and throughout the whole trial were smaller, suggesting greater caution. Collisions sometimes occurred using an SSD but not using vision, indicating that substituted information did not always result in accurate shoulder rotation judgements. No differences were found between the two SSDs. The data suggest that spatial information, provided by sensory substitution, allows the relative position of aperture panels to be internally represented, enabling the CNS to modify shoulder rotation according to aperture width. Increased buffer space indicated by greater rotations (up to approximately 35% for apertures of +18% of body width), suggests that spatial representations are not as accurate as offered by full vision
- …
