2,336 research outputs found
Complete controllability of quantum systems
Sufficient conditions for complete controllability of -level quantum
systems subject to a single control pulse that addresses multiple allowed
transitions concurrently are established. The results are applied in particular
to Morse and harmonic-oscillator systems, as well as some systems with
degenerate energy levels. Morse and harmonic oscillators serve as models for
molecular bonds, and the standard control approach of using a sequence of
frequency-selective pulses to address a single transition at a time is either
not applicable or only of limited utility for such systems.Comment: 8 pages, expanded and revised versio
Imaging the Near Field
In an earlier paper we introduced the concept of the perfect lens which
focuses both near and far electromagnetic fields, hence attaining perfect
resolution. Here we consider refinements of the original prescription designed
to overcome the limitations of imperfect materials. In particular we show that
a multi-layer stack of positive and negative refractive media is less sensitive
to imperfections. It has the novel property of behaving like a fibre-optic
bundle but one that acts on the near field, not just the radiative component.
The effects of retardation are included and minimized by making the slabs
thinner. Absorption then dominates image resolution in the near-field. The
deleterious effects of absorption in the metal are reduced for thinner layers.Comment: RevTeX, (9 pages, 8 figures
Extreme nonlinear electrodynamics in metamaterials with very small linear dielectric permittivity
We consider a sub-wavelength periodic layered medium whose slabs are filled
by arbitrary linear metamaterials and standard nonlinear Kerr media and we show
that the homogenized medium behaves as a Kerr medium whose parameters can
assume values not available in standard materials. Exploiting such a parameter
availability, we focus on the situation where the linear relative dielectric
permittivity is very small thus allowing the observation of the extreme
nonlinear regime where the nonlinear polarization is comparable with or even
greater than the linear part of the overall dielectric response. The behavior
of the electromagnetic field in the extreme nonlinear regime is very peculiar
and characterized by novel features as, for example, the transverse power flow
reversing. In order to probe the novel regime, we consider a class of fields
(transverse magnetic nonlinear guided waves) admitting full analytical
description and we show that these waves are allowed to propagate even in media
with since the nonlinear polarization produces a
positive overall effective permittivity. The considered nonlinear waves
exhibit, in addition to the mentioned features, a number of interesting
properties like hyper-focusing induced by the phase difference between the
field components.Comment: 12 pages, 7 figure
Spectral Signatures of the Diffusional Anomaly in Water
Analysis of power spectrum profiles for various tagged particle quantities in
bulk SPC/E water is used to demonstrate that variations in mobility associated
with the diffusional anomaly are mirrored in the exponent of the \onebyf\
region. Monitoring of \onebyf behaviour is shown to be a simple and direct
method for linking phenomena on three distinctive length and time scales: the
local molecular environment, hydrogen bond network reorganisations and the
diffusivity. The results indicate that experimental studies of supercooled
water to probe the density dependence of spectral features, or
equivalent stretched exponential behaviour in time-correlation functions, will
be of interest.Comment: 5 Pages, 4 Figure
Nano-Engineered Environment for Nerve Regeneration: Scaffolds, Functional Molecules and Stem Cells
One of the most complex systems in the human body is the nervous system, which is divided into the central and peripheral nervous systems. The regeneration of the CNS is a complex and challenging biological phenomenon hindered by the low regenerative capacity of neurons and the prohibition factors in response to nerve injuries. To date, no effective approach can achieve complete recovery and fully restore the functions of the nervous system once it has been damaged. Developments in neuroscience have identified properties of the local environment with a critical role in nerve regeneration. Advances in biomaterials and biomedical engineering have explored new approaches of constructing permissive environments for nerve regeneration, thereby enabling optimism with regard to nerve-injury treatment. This article reviews recent progress in nanoengineered environments for aiding nerve-injury repair and regeneration, including nanofibrous scaffolds, functional molecules, and stem cells.postprin
X-Ray Scattering Measurements of the Transient Structure of a Driven Charge-Density-Wave
We report time-resolved x-ray scattering measurements of the transient
structural response of the sliding {\bf Q} charge-density-wave (CDW) in
NbSe to a reversal of the driving electric field. The observed time scale
characterizing this response at 70K varies from 15 msec for driving
fields near threshold to 2 msec for fields well above threshold. The
position and time-dependent strain of the CDW is analyzed in terms of a
phenomenological equation of motion for the phase of the CDW order parameter.
The value of the damping constant, eV
seconds \AA, is in excellent agreement with the value
determined from transport measurements. As the driving field approaches
threshold from above, the line shape becomes bimodal, suggesting that the CDW
does not depin throughout the entire sample at one well-defined voltage.Comment: revtex 3.0, 7 figure
Nano-Engineered Environment for Nerve Regeneration: Scaffolds, Functional Molecules and Stem Cells
One of the most complex systems in the human body is the nervous system, which is divided into the central and peripheral nervous systems. The regeneration of the CNS is a complex and challenging biological phenomenon hindered by the low regenerative capacity of neurons and the prohibition factors in response to nerve injuries. To date, no effective approach can achieve complete recovery and fully restore the functions of the nervous system once it has been damaged. Developments in neuroscience have identified properties of the local environment with a critical role in nerve regeneration. Advances in biomaterials and biomedical engineering have explored new approaches of constructing permissive environments for nerve regeneration, thereby enabling optimism with regard to nerve-injury treatment. This article reviews recent progress in nanoengineered environments for aiding nerve-injury repair and regeneration, including nanofibrous scaffolds, functional molecules, and stem cells.postprin
The effect of gain saturation in a gain compensated perfect lens
The transmission of evanescent waves in a gain-compensated perfect lens is
discussed. In particular, the impact of gain saturation is included in the
analysis, and a method for calculating the fields of such nonlinear systems is
developed. Gain compensation clearly improves the resolution; however, a number
of nonideal effects arise as a result of gain saturation. The resolution
associated with the lens is strongly dependent on the saturation constant of
the active medium.Comment: to appear in J. Opt. Soc. Am.
Comprehensive assessment of a hotspot with persistent bancroftian filariasis in coastal Sri Lanka
Prospective randomized comparison of a combined ultrasonic and pneumatic lithotrite with a standard ultrasonic lithotrite for percutaneous nephrolithotomy
PURPOSE: To compare the efficiency and cost effectiveness of a combined pneumatic and ultrasonic lithotrite (Lithoclast Ultra) and a standard ultrasonic lithotrite, (LUS-1) during percutaneous nephrolithotomy.
MATERIALS AND METHODS: In a prospective randomized trial, 30 patients undergoing percutaneous nephrolithotomy (PCNL) were randomized to PCNL with either the combined pneumatic and ultrasonic lithotrite (PUL) or a standard ultrasonic lithotrite (SUL). Patient demographics, stone composition, location, pre- and post-operative stone burden, fragmentation rates, and device failures were compared.
RESULTS: There were 13 patients in the PUL group and 17 patients in the SUL group. Stone burden and location were equal. Overall, 64% of the PUL group had hard stones (defined as stones that were either pure or a mixture of cystine [3], calcium oxalate monohydrate [CaOxMono; 2], and calcium phosphate [CaPO4; 2]), and four had soft stones (3 struvite and 1 uric acid [UA]). In the SUL group, there were eight hard stones (5 CaOxMono and 3 CaPO4), and six soft stones (4 calcium oxalate dihydrate [CaOxDi] and 2 UA) (P = 0.51). Stone composition data were unavailable for five patients. Fragmentation time for the PAL was 37 minutes versus 31.5 minutes for the SUL (P = 0.22). Stone retrieval and mean operative times were similar for both groups. There were a total of three (23.1%) device-related problems in the PUL group, and eight (47%) in the SUL group. There was one (7.7%) device malfunction in the PUL group due to probe fracture. There were two (11.7%) device failures in the SUL group; one failure required the device to be reset every 30 minutes, and the second was an electrical failure. Suction tubing obstruction occurred twice (15.3%) in the PUL group and 35.3% in the SU group (P = 0.35). The stone-free rates for the PUL and SUL were 46% and 66.7%, respectively (P = 0.26).
CONCLUSION: Although the PUL was more costly, stone ablation and clearance rates were similar for both the combined pneumatic and ultrasonic device and the standard ultrasonic device. When stratified with respect to stone composition, the PUL was more efficient for harder stones, and the SUL was more efficient for softer stones
- …
