1,232 research outputs found
OCT for glaucoma diagnosis, screening and detection of glaucoma progression.
Optical coherence tomography (OCT) is a commonly used imaging modality in the evaluation of glaucomatous damage. The commercially available spectral domain (SD)-OCT offers benefits in glaucoma assessment over the earlier generation of time domain-OCT due to increased axial resolution, faster scanning speeds and has been reported to have improved reproducibility but similar diagnostic accuracy. The capabilities of SD-OCT are rapidly advancing with 3D imaging, reproducible registration, and advanced segmentation algorithms of macular and optic nerve head regions. A review of the evidence to date suggests that retinal nerve fibre layer remains the dominant parameter for glaucoma diagnosis and detection of progression while initial studies of macular and optic nerve head parameters have shown promising results. SD-OCT still currently lacks the diagnostic performance for glaucoma screening
Detecting individual ancestry in the human genome
Detecting and quantifying the population substructure present in a sample of individuals are of main interest in the fields of genetic epidemiology, population genetics, and forensics among others. To date, several algorithms have been proposed for estimating the amount of genetic ancestry within an individual. In the present review, we introduce the most widely used methods in population genetics for detecting individual genetic ancestry. We further show, by means of simulations, the performance of popular algorithms for detecting individual ancestry in various controlled demographic scenarios. Finally, we provide some hints on how to interpret the results from these algorithms
Die hereditäre hemorrhagische Telangiektasie: Untersuchungen zur Multiorganbeteiligung bei Patienten mit Epistaxis als Leitsymptom
Die hereditäre hämorrhagische Telangiektasie
(Morbus Rendu-Osler-Weber) ist ein autosomal-dominant vererbtes
vaskuläres Fehlbildungssyndrom. Hierbei werden multiple
arteriovenöse Malformationen (AVM) im Bereich der Schleimhaut
der oberen Luft- und Speisewege sowie der Haut beobachtet.
Darüber hinaus können andere Organe befallen sein wie z.B.
Lunge, Leber und ZNS. Die Diagnose HHT sollte nach den
Empfehlungen des Scientific Advisory Board der HHT Foundation
International auf der Basis verschiedener klinischer Befunde
und der Familienanamnese (sogenannten Curaçao-Kriterien)
gestellt werden. Nahezu alle an einer HHT erkrankten Patienten
leiden unter rezidivierenden Epistaxisepisoden. Hierdurch
bedingt kann die Erstdiagnose der Erkrankung häufig durch den
HNO-Arzt gestellt werden. Dem HNO-Arzt kommt somit eine
entscheidende Rolle in der Einleitung weiterer diagnostischer
Maßnahmen zur Feststellung okkulter AVM zu. Im Rahmen der
vorliegenden Untersuchung boten wir 51 Patienten mit
rezidivierender Epistaxis, bei denen die Diagnose bzw.
Verdachtsdiagnose HHT bestand, die Möglichkeit an, sich auf AVM
der inneren Organen untersuchen zu lassen. In fünf Fällen
konnte die Diagnose der HHT ausgeschlossen werden. Zusätzlich
zu der Endoskopie der oberen Luft- und Speisewege wurden ein CT
des Thorax, ein MRT vom Schädel und eine Sonographie des
Abdomens sowie Blut- und Urinuntersuchungen durchgeführt. Des
weiteren erfolgte eine augenärztliche Untersuchung. Mehr als
die Hälfte unserer Patienten wiesen bislang okkulte vaskuläre
Malformationen der inneren Organen auf, davon waren wiederum
die Hälfte therapiebedürftig
GAGA: A New Algorithm for Genomic Inference of Geographic Ancestry Reveals Fine Level Population Substructure in Europeans
Attempts to detect genetic population substructure in humans are troubled by the fact that the vast majority of the total amount of observed genetic variation is present within populations rather than between populations. Here we introduce a new algorithm for transforming a genetic distance matrix that reduces the within-population variation considerably. Extensive computer simulations revealed that the transformed matrix captured the genetic population differentiation better than the original one which was based on the T1 statistic. In an empirical genomic data set comprising 2,457 individuals from 23 different European subpopulations, the proportion of individuals that were determined as a genetic neighbour to another individual from the same sampling location increased from 25% with the original matrix to 52% with the transformed matrix. Similarly, the percentage of genetic variation explained between populations by means of Analysis of Molecular Variance (AMOVA) increased from 1.62% to 7.98%. Furthermore, the first two dimensions of a classical multidimensional scaling (MDS) using the transformed matrix explained 15% of the variance, compared to 0.7% obtained with the original matrix. Application of MDS with Mclust, SPA with Mclust, and GemTools algorithms to the same dataset also showed that the transformed matrix gave a better association of the genetic clusters with the sampling locations, and particularly so when it was used in the AMOVA framework with a genetic algorithm. Overall, the new matrix transformation introduced here substantially reduces the within population genetic differentiation, and can be broadly applied to methods such as AMOVA to enhance their sensitivity to reveal population substructure. We herewith provide a publically available (http://www.erasmusmc.nl/fmb/resources/GAGA) model-free method for improved genetic population substructure detection that can be applied to human as well as any other species data in future studies relevant to evolutionary biology, behavioural ecology, medicine, and forensics
Three-Dimensional Spectral-Domain Optical Coherence Tomography Data Analysis for Glaucoma Detection
Purpose: To develop a new three-dimensional (3D) spectral-domain optical coherence tomography (SD-OCT) data analysis method using a machine learning technique based on variable-size super pixel segmentation that efficiently utilizes full 3D dataset to improve the discrimination between early glaucomatous and healthy eyes. Methods: 192 eyes of 96 subjects (44 healthy, 59 glaucoma suspect and 89 glaucomatous eyes) were scanned with SD-OCT. Each SD-OCT cube dataset was first converted into 2D feature map based on retinal nerve fiber layer (RNFL) segmentation and then divided into various number of super pixels. Unlike the conventional super pixel having a fixed number of points, this newly developed variable-size super pixel is defined as a cluster of homogeneous adjacent pixels with variable size, shape and number. Features of super pixel map were extracted and used as inputs to machine classifier (LogitBoost adaptive boosting) to automatically identify diseased eyes. For discriminating performance assessment, area under the curve (AUC) of the receiver operating characteristics of the machine classifier outputs were compared with the conventional circumpapillary RNFL (cpRNFL) thickness measurements. Results: The super pixel analysis showed statistically significantly higher AUC than the cpRNFL (0.855 vs. 0.707, respectively, p = 0.031, Jackknife test) when glaucoma suspects were discriminated from healthy, while no significant difference was found when confirmed glaucoma eyes were discriminated from healthy eyes. Conclusions: A novel 3D OCT analysis technique performed at least as well as the cpRNFL in glaucoma discrimination and even better at glaucoma suspect discrimination. This new method has the potential to improve early detection of glaucomatous damage. © 2013 Xu et al
Recommended from our members
Aligning scan acquisition circles in optical coherence tomography images of the retinal nerve fibre layer
Optical coherence tomography (OCT) is widely used in the assessment of retinal nerve fibre layer thickness (RNFLT) in glaucoma. Images are typically acquired with a circular scan around the optic nerve head. Accurate registration of OCT scans is essential for measurement reproducibility and longitudinal examination. This study developed and evaluated a special image registration algorithm to align the location of the OCT scan circles to the vessel features in the retina using probabilistic modelling that was optimised by an expectation-maximization algorithm. Evaluation of the method on 18 patients undergoing large numbers of scans indicated improved data acquisition and better reproducibility of measured RNFLT when scanning circles were closely matched. The proposed method enables clinicians to consider the RNFLT measurement and its scan circle location on the retina in tandem, reducing RNFLT measurement variability and assisting detection of real change of RNFLT in the longitudinal assessment of glaucoma
Gold nanorods as a contrast agent for Doppler optical coherence tomography
Purpose: To investigate gold nanorods (GNRs) as a contrast agent to enhance Doppler optical coherence tomography (OCT) imaging of the intrascleral aqueous humor outflow. Methods: A serial dilution of GNRs was scanned with a spectral-domain OCT device (Bioptigen, Durham, NC) to visualize Doppler signal. Doppler measurements using GNRs were validated using a controlled flow system. To demonstrate an application of GNR enhanced Doppler, porcine eyes were perfused at constant pressure with mock aqueous alone or 1.0×10 12 GNR/mL mixed with mock aqueous. Twelve Doppler and volumetric SD-OCT scans were obtained from the limbus in a radial fashion incremented by 30°, forming a circular scan pattern. Volumetric flow was computed by integrating flow inside non-connected vessels throughout all 12 scans around the limbus. Results: At the GNR concentration of 0.7×1012 GNRs/mL, Doppler signal was present through the entire depth of the testing tube without substantial attenuation. A well-defined laminar flow profile was observed for Doppler images of GNRs flowing through the glass capillary tube. The Doppler OCT measured flow profile was not statistically different from the expected flow profile based upon an autoregressive moving average model, with an error of -0.025 to 0.037 mm/s (p = 0.6435). Cross-sectional slices demonstrated the ability to view anterior chamber outflow ex-vivo using GNR-enhanced Doppler OCT. Doppler volumetric flow measurements were comparable to flow recorded by the perfusion system. Conclusions: GNRs created a measureable Doppler signal within otherwise silent flow fields in OCT Doppler scans. Practical application of this technique was confirmed in a constant pressure ex-vivo aqueous humor outflow model in porcine eyes. © 2014 Wang et al
- …