4,863 research outputs found
Laser spectroscopy of LaS: Hyperfine structure in the B2Σ+-X2Σ+ (0,0) band
The B 2Σ +-X 2Σ + (0,0) band of LaS was studied using the technique of laser vaporization/reaction supersonic free jet expansion and laser induced fluorescence spectroscopy. The magnetic hyperfine structure caused by the 57 139La nucleus (I=7/2) was well resolved. Least-squares fit of the hyperfine transition line positions yielded a comprehensive set of rotational, spin, and hyperfine parameters for both the B 2Σ + and X 2Σ + states. The magnetic hyperfine parameters obtained were interpreted, which yielded information about the occupation of molecular orbitals giving rise to the states studied in this molecule.published_or_final_versio
Finite-temperature Gutzwiller projection for strongly correlated electron systems
We generalized the Gutzwiller projectional variational method for the ground state of strongly correlated electron systems to the case of finite temperature. Under the Gutzwiller approximation, we show that this maps to a finite temperature renormalized mean-field theory. As one of the key ingredients in the theory, we obtained an explicit expression of the projection entropy or the entropy change due to the projection. We illustrate the application of the theory to the Anderson impurity problem and the half-filled Hubbard model and compare the theory to more elaborate techniques. We find qualitative agreement. The theory can be applied to a wide variety of Hubbard, t-J, and Anderson impurity models. © 2010 The American Physical Society.published_or_final_versio
Measurements of neutral vector resonance in Higgsless models at the LHC
In Higgsless models, new vector resonances appear to restore the unitarity of
the W_L W_L scattering amplitude without the Higgs boson. In the ideal
delocalized three site Higgsless model, one of large prodcution cross section
of the neutral vector resonance (Z') at the Large Hadron Collider is the
W-associated production, pp \to Z'W \to WWW. Although the dileptonic decay
channnel, l\nu l'\nu 'jj, is experimentally clean to search for the Z' signals,
it is difficult to reconstruct the Z' invariant mass due to the two neutrinos
in the final state. We study collider signatures of Z' using the
M_{T2}-Assisted On-Shell (MAOS) reconstruction of the missing neutrino momenta.
We show the prospect of the Z' mass determination in the channel, l\nu l'\nu
'jj, at the Large Hadron Collider.Comment: 16 pages, 6 figures, 5 tables; v2: references added, minor
corrections, version published in JHE
Momentum asymmetries as CP violating observables
Three body decays can exhibit CP violation that arises from interfering
diagrams with different orderings of the final state particles. We construct
several momentum asymmetry observables that are accessible in a hadron collider
environment where some of the final state particles are not reconstructed and
not all the kinematic information can be extracted. We discuss the
complications that arise from the different possible production mechanisms of
the decaying particle. Examples involving heavy neutralino decays in
supersymmetric theories and heavy Majorana neutrino decays in Type-I seesaw
models are examined.Comment: 20 pages, 9 figures. Clarifying comments and one reference added,
matches published versio
Spin and Chirality Effects in Antler-Topology Processes at High Energy Colliders
We perform a model-independent investigation of spin and chirality
correlation effects in the antler-topology processes
at high energy colliders with polarized
beams. Generally the production process
can occur not only through the -channel exchange of vector bosons,
, including the neutral Standard Model (SM) gauge bosons,
and , but also through the - and -channel exchanges of new
neutral states, and , and the -channel
exchange of new doubly-charged states, . The general set of
(non-chiral) three-point couplings of the new particles and leptons allowed in
a renormalizable quantum field theory is considered. The general spin and
chirality analysis is based on the threshold behavior of the excitation curves
for pair production in collisions with
longitudinal and transverse polarized beams, the angular distributions in the
production process and also the production-decay angular correlations. In the
first step, we present the observables in the helicity formalism. Subsequently,
we show how a set of observables can be designed for determining the spins and
chiral structures of the new particles without any model assumptions. Finally,
taking into account a typical set of approximately chiral invariant scenarios,
we demonstrate how the spin and chirality effects can be probed experimentally
at a high energy collider.Comment: 50 pages, 14 figures, 6 tables, matches version published in EPJ
Strain- and Adsorption-Dependent Electronic States and Transport or Localization in Graphene
The chapter generalizes results on influence of uniaxial strain and
adsorption on the electron states and charge transport or localization in
graphene with different configurations of imperfections (point defects):
resonant (neutral) adsorbed atoms either oxygen- or hydrogen-containing
molecules or functional groups, vacancies or substitutional atoms, charged
impurity atoms or molecules, and distortions. To observe electronic properties
of graphene-admolecules system, we applied electron paramagnetic resonance
technique in a broad temperature range for graphene oxides as a good basis for
understanding the electrotransport properties of other active carbons. Applied
technique allowed observation of possible metal-insulator transition and
sorption pumping effect as well as discussion of results in relation to the
granular metal model. The electronic and transport properties are calculated
within the framework of the tight-binding model along with the Kubo-Greenwood
quantum-mechanical formalism. Depending on electron density and type of the
sites, the conductivity for correlated and ordered adsorbates is found to be
enhanced in dozens of times as compared to the cases of their random
distribution. In case of the uniaxially strained graphene, the presence of
point defects counteracts against or contributes to the band-gap opening
according to their configurations. The band-gap behaviour is found to be
nonmonotonic with strain in case of a simultaneous action of defect ordering
and zigzag deformation. The amount of localized charge carriers (spins) is
found to be correlated with the content of adsorbed centres responsible for the
formation of potential barriers and, in turn, for the localization effects.
Physical and chemical states of graphene edges, especially at a uniaxial strain
along one of them, play a crucial role in electrical transport phenomena in
graphene-based materials.Comment: 16 pages, 10 figure
Cost-effectiveness analysis of 3-D computerized tomography colonography versus optical colonoscopy for imaging symptomatic gastroenterology patients.
BACKGROUND: When symptomatic gastroenterology patients have an indication for colonic imaging, clinicians have a choice between optical colonoscopy (OC) and computerized tomography colonography with three-dimensional reconstruction (3-D CTC). 3-D CTC provides a minimally invasive and rapid evaluation of the entire colon, and it can be an efficient modality for diagnosing symptoms. It allows for a more targeted use of OC, which is associated with a higher risk of major adverse events and higher procedural costs. A case can be made for 3-D CTC as a primary test for colonic imaging followed if necessary by targeted therapeutic OC; however, the relative long-term costs and benefits of introducing 3-D CTC as a first-line investigation are unknown. AIM: The aim of this study was to assess the cost effectiveness of 3-D CTC versus OC for colonic imaging of symptomatic gastroenterology patients in the UK NHS. METHODS: We used a Markov model to follow a cohort of 100,000 symptomatic gastroenterology patients, aged 50 years or older, and estimate the expected lifetime outcomes, life years (LYs) and quality-adjusted life years (QALYs), and costs (£, 2010-2011) associated with 3-D CTC and OC. Sensitivity analyses were performed to assess the robustness of the base-case cost-effectiveness results to variation in input parameters and methodological assumptions. RESULTS: 3D-CTC provided a similar number of LYs (7.737 vs 7.739) and QALYs (7.013 vs 7.018) per individual compared with OC, and it was associated with substantially lower mean costs per patient (£467 vs £583), leading to a positive incremental net benefit. After accounting for the overall uncertainty, the probability of 3-D CTC being cost effective was around 60 %, at typical willingness-to-pay values of £20,000-£30,000 per QALY gained. CONCLUSION: 3-D CTC is a cost-saving and cost-effective option for colonic imaging of symptomatic gastroenterology patients compared with OC
Modulating attentional load affects numerosity estimation: evidence against a pre-attentive subitizing mechanism
Traditionally, the visual enumeration of a small number of items (1 to about 4), referred to as subitizing, has been thought of as a parallel and pre-attentive process and functionally different from the serial attentive enumeration of larger numerosities. We tested this hypothesis by employing a dual task paradigm that systematically manipulated the attentional resources available to an enumeration task. Enumeration accuracy for small numerosities was severely decreased as more attentional resources were taken away from the numerical task, challenging the traditionally held notion of subitizing as a pre-attentive, capacity-independent process. Judgement of larger numerosities was also affected by dual task conditions and attentional load. These results challenge the proposal that small numerosities are enumerated by a mechanism separate from large numerosities and support the idea of a single, attention-demanding enumeration mechanism
MiR-637 maintains the balance between adipocytes and osteoblasts by directly targeting Osterix
Bone development is dynamically regulated by homeostasis, in which a balance between adipocytes and osteoblasts is maintained. Disruption of this differentiation balance leads to various bone-related metabolic diseases, including osteoporosis. In the present study, a primate-specific microRNA (miR-637) was found to be involved in the differentiation of human mesenchymal stem cells (hMSCs). Our preliminary data indicated that miR-637 suppressed the growth of hMSCs and induced S-phase arrest. Expression of miR-637 was increased during adipocyte differentiation (AD), whereas it was decreased during osteoblast differentiation (OS), which suggests miR-637 could act as a mediator of adipoosteogenic differentiation. Osterix (Osx), a significant transcription factor of osteoblasts, was shown to be a direct target of miR-637, which significantly enhanced AD and suppressed OS in hMSCs through direct suppression of Osx expression. Furthermore, miR-637 also significantly enhanced de novo adipogenesis in nude mice. In conclusion, our data indicated that the expression of miR-637 was indispensable for maintaining the balance of adipocytes and osteoblasts. Disruption of miR-637 expression patterns leads to irreversible damage to the balance of differentiation in bone marrow. © 2011 Zhang et al.published_or_final_versio
Potentiation of thrombus instability: a contributory mechanism to the effectiveness of antithrombotic medications
© The Author(s) 2018The stability of an arterial thrombus, determined by its structure and ability to resist endogenous fibrinolysis, is a major determinant of the extent of infarction that results from coronary or cerebrovascular thrombosis. There is ample evidence from both laboratory and clinical studies to suggest that in addition to inhibiting platelet aggregation, antithrombotic medications have shear-dependent effects, potentiating thrombus fragility and/or enhancing endogenous fibrinolysis. Such shear-dependent effects, potentiating the fragility of the growing thrombus and/or enhancing endogenous thrombolytic activity, likely contribute to the clinical effectiveness of such medications. It is not clear how much these effects relate to the measured inhibition of platelet aggregation in response to specific agonists. These effects are observable only with techniques that subject the growing thrombus to arterial flow and shear conditions. The effects of antithrombotic medications on thrombus stability and ways of assessing this are reviewed herein, and it is proposed that thrombus stability could become a new target for pharmacological intervention.Peer reviewedFinal Published versio
- …
