2,097 research outputs found
Evolution of the neobladder: A critical review of open and intracorporeal neobladder reconstruction techniques
Orthotopic neobladder is an attractive alternative to the ileal conduit following radical cystectomy. Robotic cystectomy is gaining popularity although the uptake of neobladder reconstruction is low, with the majority of cases being constructed extracorporeally via a mini-laparotomy. Minimally invasive cystectomy using the robotic platform facilitates intracorporeal neobladder reconstruction and several techniques have been described. This review discusses issues relating to patient selection, and describes existing techniques of open surgical neobladder reconstruction and their evolution to suit an intracorporeal approach. A Medline search for publications from January 1970 to September 2015 with the following keyword search criteria was performed: radical cystectomy, robotic cystectomy, intracorporeal, neobladder, orthotopic bladder reconstruction, surgical technique, patient selection and ureteric–ileal anastomosis
Robotic Assisted Radical Cystectomy with Extracorporeal Urinary Diversion Does Not Show a Benefit over Open Radical Cystectomy: A Systematic Review and Meta-Analysis of Randomised Controlled Trials
Background: The number of robotic assisted radical cystectomy (RARC) procedures is increasing despite the lack of Level I evidence showing any advantages over open radical cystectomy (ORC). However, several systematic reviews with meta-analyses including non-randomised studies, suggest an overall benefit for RARC compared to ORC. We performed a systematic review with meta-analysis of randomised controlled trials (RCTs) to evaluate the perioperative morbidity and efficacy of RARC compared to ORC in patients with bladder cancer.
Methods: Literature searches of Medline/Pubmed, Embase, Web of Science and clinicaltrials.gov databases up to 10th March 2016 were performed. The inclusion criteria for eligible studies were RCTs which compared perioperative outcomes of ORC and RARC for bladder cancer. Primary objective was perioperative and histopathological outcomes of RARC versus ORC while the secondary objective was quality of life assessment (QoL), oncological outcomes and cost analysis.
Results: Four RCTs (from 5 articles) met the inclusion criteria, with a total of 239 patients all with extracorporeal urinary diversion. Patient demographics and clinical characteristics of RARC and ORC patients were evenly matched. There was no significant difference between groups in perioperative morbidity, length of stay, positive surgical margin, lymph node yield and positive lymph node status. RARC group had significantly lower estimated blood loss (p<0.001) and wound complications (p = 0.03) but required significantly longer operating time (p<0.001). QoL was not measured uniformly across trials and cost analysis was reported in one RCTs. A test for heterogeneity did highlight differences across operating time of trials suggesting that surgeon experience may influence outcomes.
Conclusions: This study does not provide evidence to support a benefit for RARC compared to ORC. These results may not have inference for RARC with intracorporeal urinary diversion. Well-designed trials with appropriate endpoints conducted by equally experienced ORC and RARC surgeons will be needed to address this
Benefits of robotic cystectomy with intracorporeal diversion for patients with low cardiorespiratory fitness: A prospective cohort study
BACKGROUND: Patients undergoing radical cystectomy have associated comorbidities resulting in reduced cardiorespiratory fitness. Preoperative cardiopulmonary exercise testing (CPET) measures including anaerobic threshold (AT) can predict major adverse events (MAE) and hospital length of stay (LOS) for patients undergoing open and robotic cystectomy with extracorporeal diversion. Our objective was to determine the relationship between CPET measures and outcome in patients undergoing robotic radical cystectomy and intracorporeal diversion (intracorporeal robotic assisted radical cystectomy [iRARC]).
METHODS: A single institution prospective cohort study in patients undergoing iRARC for muscle invasive and high-grade bladder cancer. Inclusion: patients undergoing standardised CPET before iRARC. Exclusions: patients not consenting to data collection. Data on CPET measures (AT, ventilatory equivalent for carbon dioxide [VE/VCO2] at AT, peak oxygen uptake [VO2]), and patient demographics prospectively collected. Outcome measurements included hospital LOS; 30-day MAE and 90-day mortality data, which were prospectively recorded. Descriptive and regression analyses were used to assess whether CPET measures were associated with or predicted outcomes.
RESULTS: From June 2011 to March 2015, 128 patients underwent radical cystectomy (open cystectomy, n = 17; iRARC, n = 111). A total of 82 patients who underwent iRARC and CPET and consented to participation were included. Median (interquartile range): age = 65 (58–73); body mass index = 27 (23–30); AT = 10.0 (9–11), Peak VO2 = 15.0 (13–18.5), VE/VCO2 (AT) = 33.0 (30–38). 30-day MAE = 14/111 (12.6%): death = 2, multiorgan failure = 2, abscess = 2, gastrointestinal = 2, renal = 6; 90-day mortality = 3/111 (2.7%). AT, peak VO2, and VE/VCO2 (at AT) were not significant predictors of 30-day MAE or LOS. The results are limited by the absence of control group undergoing open surgery.
CONCLUSIONS: Poor cardiorespiratory fitness does not predict increased hospital LOS or MAEs in patients undergoing iRARC. Overall, MAE and LOS comparable with other series
Single-atom imaging of fermions in a quantum-gas microscope
Single-atom-resolved detection in optical lattices using quantum-gas
microscopes has enabled a new generation of experiments in the field of quantum
simulation. Fluorescence imaging of individual atoms has so far been achieved
for bosonic species with optical molasses cooling, whereas detection of
fermionic alkaline atoms in optical lattices by this method has proven more
challenging. Here we demonstrate single-site- and single-atom-resolved
fluorescence imaging of fermionic potassium-40 atoms in a quantum-gas
microscope setup using electromagnetically-induced-transparency cooling. We
detected on average 1000 fluorescence photons from a single atom within 1.5s,
while keeping it close to the vibrational ground state of the optical lattice.
Our results will enable the study of strongly correlated fermionic quantum
systems in optical lattices with resolution at the single-atom level, and give
access to observables such as the local entropy distribution and individual
defects in fermionic Mott insulators or anti-ferromagnetically ordered phases.Comment: 7 pages, 5 figures; Nature Physics, published online 13 July 201
Can renal and bladder ultrasound replace CT urogram in patients investigated for microscopic hematuria?
PURPOSE: Computed tomography urogram (CTU) is recommended when investigating patients with hematuria. We determine the incidence of urinary tract cancer and compare the diagnostic accuracy of CTU and renal and bladder ultrasound (RBUS) at identifying urinary tract cancer. METHODS: The DETECT I study (clinicaltrials.gov NCT02676180) is a prospective observational study recruiting patients ≥18 years following a presentation of macroscopic or microscopic haematuria at 40 hospitals. All patients had cystoscopy and upper tract imaging (CTU, RBUS or both). RESULTS: 3,556 patients with a median age of 68 years were recruited, of which 2166 had RBUS and 1692 had CTU in addition to cystoscopy. The incidence of bladder, renal and upper tract urothelial cancer (UTUC) were 11.0%, 1.4% and 0.8% respectively in macroscopic hematuria patients. Patients with microscopic hematuria had a 2.7%, 0.4% and 0% incidence of bladder, renal and UTUC respectively. The sensitivity and negative predictive value (NPV) of RBUS for the detection of renal cancer was 85.7% and 99.9% respectively but 14.3% and 99.7% for the detection of UTUC. RBUS was poor at identifying renal calculi. Sensitivity of RBUS was lower than CTU for the detection of bladder cancer (both <85%). Cystoscopy has a specificity and PPV of 98.3% and 83.9% respectively. CONCLUSION: CTU can be safely replaced with RBUS in patients with microscopic hematuria. The incidence of UTUC is 0.8% in patients with macroscopic hematuria and CTU is recommended. Patients with suspected renal calculi will require non-contrast renal tract CT. Imaging cannot replace cystoscopy to diagnose bladder cancer
Blood Transfusion Requirement and not Preoperative Anaemia is associated with Perioperative Complications following Intracorporeal Robotic Assisted Radical Cystectomy
OBJECTIVES: To assess the prevalence of preoperative anaemia and the impact of preoperative anaemia and blood transfusion requirement on 30- and 90-day complications in a cohort of patients undergoing robotic assisted radical cystectomy with intracorporeal urinary diversion (iRARC). PATIENTS & METHODS: IRARC was performed on 166 patients between June 2011-March 2016. Prospective data was collected for patient demographics, clinical and pathological characteristics, perioperative variables, transfusion requirements and hospital length of stay. Thirty- and 90-day complications were classified according to the modified Memorial Sloan-Kettering Cancer Center Clavian-Dindo system. RESULTS: Preoperative anaemia was common (43.4%) and greatest in patients receiving neoadjuvant chemotherapy (48.6%) (p<0.001). Patients with preoperative anaemia were significantly more likely to have an Ileal conduit (p=0.033), higher cystectomy stage (≥pT3) (p=0.028) and a lower lymph node yield (p=0.031). Preoperative anaemia was not associated with increased perioperative morbidity but was associated with the need for blood transfusion (p=0.001). Blood transfusion was required in 20.4% of patients with intraoperative and postoperative blood transfusion rate was 10.2% and 13.9% respectively. The 30-day all complication rate and 30-day major complication rate was 55.4% and 15.7% respectively while 90-day all complication rate and 90-day major complication rate were 65.7% and 19.3% respectively. Intraoperative blood transfusion was not associated with increased complications but postoperative blood transfusion requirement was independently associated with perioperative morbidity: all 30 day complications (p=0.003), all 90-day complications (p=0.009) and 90-day major complications (p=0.004). CONCLUSION: The presence of preoperative anaemia in patients undergoing iRARC is not associated with increased surgical risk although preoperative anaemic patients were significantly more likely to require blood transfusion. Blood transfusion requirement and specifically postoperative blood transfusion is independently associated with perioperative morbidity and is an important factor for the optimisation of postoperative outcomes
Cyborg Activism: Exploring the reconfigurations of democratic subjectivity in Anonymous
This article develops the concept of cyborg activism as novel configuration of democratic subjectivity in the Information Age by exploring the online collectivity Anonymous as a prototype. By fusing elements of human/machine and organic/digital the cyborg disrupts modern logics of binary thinking. Cyborg activism emerges as the reconfiguration of equality/hierarchy, reason/emotion, and nihilism/idealism. Anonymous demonstrates how through the use of contingent and ephemeral digital personae hierarchies in cyborg activism prove more volatile than in face-to-face settings. Emotions appear as an essential part of a politics of passion, which enables pursuing laughter and joy, expressing anger, and experiencing empowerment as part of a reasoned, strategic politics. Anonymous’ political content reconfigures nihilist sentiments, frustration, and political disenchantment on the one hand with idealist world views on the other. This enables the cohabitation and partial integration of a great diversity of political claims rooted in various ideologies
Measurement of the inclusive and dijet cross-sections of b-jets in pp collisions at sqrt(s) = 7 TeV with the ATLAS detector
The inclusive and dijet production cross-sections have been measured for jets
containing b-hadrons (b-jets) in proton-proton collisions at a centre-of-mass
energy of sqrt(s) = 7 TeV, using the ATLAS detector at the LHC. The
measurements use data corresponding to an integrated luminosity of 34 pb^-1.
The b-jets are identified using either a lifetime-based method, where secondary
decay vertices of b-hadrons in jets are reconstructed using information from
the tracking detectors, or a muon-based method where the presence of a muon is
used to identify semileptonic decays of b-hadrons inside jets. The inclusive
b-jet cross-section is measured as a function of transverse momentum in the
range 20 < pT < 400 GeV and rapidity in the range |y| < 2.1. The bbbar-dijet
cross-section is measured as a function of the dijet invariant mass in the
range 110 < m_jj < 760 GeV, the azimuthal angle difference between the two jets
and the angular variable chi in two dijet mass regions. The results are
compared with next-to-leading-order QCD predictions. Good agreement is observed
between the measured cross-sections and the predictions obtained using POWHEG +
Pythia. MC@NLO + Herwig shows good agreement with the measured bbbar-dijet
cross-section. However, it does not reproduce the measured inclusive
cross-section well, particularly for central b-jets with large transverse
momenta.Comment: 10 pages plus author list (21 pages total), 8 figures, 1 table, final
version published in European Physical Journal
Performance of the CMS Cathode Strip Chambers with Cosmic Rays
The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device
in the CMS endcaps. Their performance has been evaluated using data taken
during a cosmic ray run in fall 2008. Measured noise levels are low, with the
number of noisy channels well below 1%. Coordinate resolution was measured for
all types of chambers, and fall in the range 47 microns to 243 microns. The
efficiencies for local charged track triggers, for hit and for segments
reconstruction were measured, and are above 99%. The timing resolution per
layer is approximately 5 ns
- …
