34 research outputs found
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments
Target dark matter detection rates in models with a well-tempered neutralino
In the post-LEP2 era, and in light of recent measurements of the cosmic
abundance of cold dark matter (CDM) in the universe from WMAP, many
supersymmetric models tend to predict 1. an overabundance of CDM and 2.
pessimistically low rates for direct detection of neutralino dark matter.
However, in models with a ``well-tempered neutralino'', where the neutralino
composition is adjusted to give the measured abundance of CDM, the neutralino
is typically of the mixed bino-wino or mixed bino-higgsino state. Along with
the necessary enhancement to neutralino annihilation rates, these models tend
to give elevated direct detection scattering rates compared to predictions from
SUSY models with universal soft breaking terms. We present neutralino direct
detection cross sections from a variety of models containing a well-tempered
neutralino, and find cross section asymptotes with detectable scattering rates.
These asymptotic rates provide targets that various direct CDM detection
experiments should aim for. In contrast, in models where the neutralino mass
rather than its composition is varied to give the WMAP relic density via either
resonance annihilation or co-annihilation, the neutralino remains essentially
bino-like, and direct detection rates may be below the projected reaches of all
proposed experiments.Comment: 13 pages including 1 EPS figur
Effects of Nitrogen contamination in liquid Argon
A dedicated test of the effects of Nitrogen contamination in liquid Argon has
been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP
R&D program. A detector has been designed and assembled for this specific task
and connected to a system for the injection of controlled amounts of gaseous
Nitrogen into the liquid Argon. Purpose of the test is to detect the reduction
of the Ar scintillation light emission as a function of the amount of the
Nitrogen contaminant injected in the Argon volume. A wide concentration range,
spanning from about 10^-1 ppm up to about 10^3 ppm, has been explored.
Measurements have been done with electrons in the energy range of minimum
ionizing particles (gamma-conversion from radioactive sources). Source spectra
at different Nitrogen contaminations are analyzed, showing sensitive reduction
of the scintillation yield at increasing concentrations. The rate constant of
the light quenching process induced by Nitrogen in liquid Ar has been found to
be k(N2)=0.11 micros^-1 ppm^-1. Direct PMT signals acquisition at high time
resolution by fast Waveform recording allowed to extract with high precision
the main characteristics of the scintillation light emission in pure and
contaminated LAr. In particular, the decreasing behavior in lifetime and
relative amplitude of the slow component is found to be appreciable from O(1
ppm) of Nitrogen concentrations
Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light
A dedicated test of the effects of Oxygen contamination in liquid Argon has
been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP
R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a
small (0.7 lt) dedicated detector, coupled with a system for the injection of
controlled amounts of gaseous Oxygen. Purpose of the test with the 0.7 lt
detector is to detect the reduction of the long-lived component lifetime of the
Argon scintillation light emission at increasing O2 concentration. Data from
the WArP prototype are used for determining the behavior of both the ionization
electron lifetime and the scintillation long-lived component lifetime during
the O2-purification process activated in closed loop during the acquisition
run. The electron lifetime measurements allow to infer the O2 content of the
Argon and correlate it with the long-lived scintillation lifetime data. The
effect of Oxygen contamination on the scintillation light has been thus
measured over a wide range of O2 concentration, spanning from about 10^-3 ppm
up to about 10 ppm. The rate constant of the light quenching process induced by
Oxygen in LAr has been found to be k'(O2)=0.54+-0.03 micros^-1 ppm^-1
Imaging Characteristics of an Amorphous Silicon Flat-Panel Detector for Digital Chest Radiography
Competition driven by retinal waves promotes morphological and functional synaptic development of neurons in the superior colliculus
Recommended from our members
A confirmed case of xylazine-induced skin ulcers in a person who injects drugs in Miami, Florida, USA
Xylazine is an alpha-2 adrenergic receptor agonist that has emerged as a contaminant in the illicit drug supply of fentanyl. Xylazine use may be suspected in naloxone-resistant overdoses and atypical, chronic wounds in people who use drugs (PWUD). This case is unique because it is the first case to our knowledge describing wound care for a xylazine-induced wound with a confirmatory xylazine test strip (XTS) in the setting of a syringe services program (SSP) and in the state of Florida.
A 43-year-old woman with a past medical history of severe opioid use disorder and stimulant use disorder presented to a student-run clinic at a Miami SSP for wound care. She had multiple ulcerations diffusely over her bilateral forearms with surrounding erythema and warmth. Seven weeks later, she presented to clinic again for wound care because her wounds had progressed. At this visit, a XTS was used to confirm the presence of xylazine in her urine. Wound care management and harm reduction strategies employed at both visits were informed by best clinical judgement due to lack of formal guidelines at the time. Wound outcomes are unknown as the patient has not returned to clinic.
Many PWUD at highest risk for acute and chronic health consequences of xylazine-adulterated fentanyl do not have access to healthcare outside of low barrier clinics and SSPs due to lack of insurance or mistrust of the traditional healthcare system due to stigma. There is an urgent need for access to XTS for PWUD and clinical practice guidelines for the treatment of xylazine-related wounds in outpatient clinics
Chest Radiography: Optimization of X-ray Spectrum for Cesium Iodide–Amorphous Silicon Flat-Panel Detector
First results from a Dark Matter search with liquid Argon at 87 K in the Gran Sasso Underground Laboratory
Recommended from our members
Prevalence of xylazine among people who inject drugs seeking medical care at a syringe services program clinic: Miami, Florida, 2023
Background: We aimed to report the preliminary xylazine prevalence among people who inject drugs (PWID) treated at a student-run free clinic in Miami, FL, USA and to identify characteristics associated with screening positive for xylazine. Methods: A retrospective chart review of 59 patients presenting to a syringe services program (SSP) clinic in was conducted between April 27th and August 17th, 2023. We measured presence of xylazine with rapid visual immunoassay strips on patient urine samples. Results: Xylazine was present in 55.9 % (33/59) of urine samples including 2 without detected opioids. Xylazine presence was significantly associated with unsheltered homelessness (p = 0.018), presence of wound(s) (p = 0.008), and testing positive for hepatitis C antibody (p = 0.014), fentanyl (p = 0.005) and MDMA (p = 0.002). Conclusions: A high prevalence of xylazine in the Southeastern United States furthers evidence of the geographical spread of xylazine and rapidly evolving illicit drug supply. Widespread xylazine screening is urgently needed to inform people who inject drugs and to studyinterventions to minimize harms associated with xylazine
