2,327 research outputs found

    Primary nodal anthracosis identified by EBUS-TBNA as a cause of FDG PET/CT positive mediastinal lymphadenopathy.

    No full text
    Isolated mediastinal lymphadenopathy can result from a number of potentially serious aetiologies. Traditionally those presenting with mediastinal lymphadenopathy would undergo mediastinoscopy to elucidate a final diagnosis or receive empirical treatment. There is now increased utilization of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), in this setting. Five cases of mediastinal lymphadenopathy are presented here in which lymph node anthracosis was identified as the primary diagnosis using EBUS-TBNA. They were female, non-smokers presenting with non-specific symptoms, who retrospectively reported cooking over wood fires. Four were from South Asia. Three were investigated by F-18-fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scanning and increased signal was identified in the anthracotic nodes sampled. With expansion of PET/CT and EBUS-TBNA services it is likely that primary nodal anthracosis will be encountered more frequently and should be considered in the differential diagnosis of those with PET/CT positive lymphadenopathy. It may mimic pathologies including tuberculosis and malignancy, thus accurate sampling and follow-up are essential

    A content analysis of district level health data in Uttar Pradesh, India

    Get PDF
    The study aimed to conduct a content analysis of the different types of public health data maintained by the Health Department, the Department of Women and Child Development, and the private for profit and not for profit health sectors and the links that exist between them in terms of data sharing. Method: In two districts, Sitapur and Unnao, an IDEAS/PHFI study team visited district, sub-district and village level health facilities (public and private) as well as NRHM programme management units, and Women and Child Development offices. The team collected all available forms and interviewed facility staff and programme managers to understand the types of data collected, their flow and data sharing. Case studies of three not-for-profit non-governmental organisations were developed to understand how they maintain and share data with the public health system. Findings: The public health system collects a large volume of health data; Data exist for all of WHO’s health system building blocks, but it is unevenly distributed. There are fewer data on contextual information, e.g. village infrastructure and demographic profile, compared to service delivery; There is little formal or institutional routine data sharing between the public and private health sectors, and between the health department and other related departments such as Women and Child Development

    Evaluation of serum inflammatory biomarkers as predictors of treatment outcome in pulmonary tuberculosis

    Get PDF
    Objective: To evaluate C-reactive protein (CRP), globulin and white blood cell (WBC) count as predictors of treatment outcome in pulmonary tuberculosis (PTB).Methods: An observational study of patients with active PTB was conducted at a tertiary centre. All patients had serum CRP, globulin and WBC measured at baseline and at 2 months following commencement of treatment. The outcome of interest was requirement for extension of treatment beyond 6 months.Results: There were 226 patients included in the study. Serum globulin 45 g/l was the only baseline biomarker evaluated that independently predicted requirement for treatment extension (OR 3.42, 95%CI 1.597.32, P 0.001). An elevated globulin level that failed to normalise at 2 months was also associated with increased requirement for treatment extension (63.9% vs. 5.1%, P 0.001), and had a low negative likelihood ratio (0.07) for exclusion of requirement for treatment extension. On multivariable analysis, an elevated globulin that failed to normalise at 2 months was independently associated with requirement for treatment extension (OR 6.13, 95%CI 2.2316.80, P 0.001).Conclusions: Serum globulin independently predicts requirement for treatment extension in PTB and outperforms CRP and WBC as a predictive biomarker. Normalisation of globulin at 2 months following treatment commencement is associated with low risk of requirement for treatment extension.</p

    Informed Decisions for Actions in Maternal and Newborn Health 2010–17 Report What works, why and how in maternal and newborn health

    Get PDF
    IDEAS is a measurement, learning and evaluation project based at the London School of Hygiene & Tropical Medicine (LSHTM). The project aims to find out “what works, why, and how” for maternal and newborn health in three low-resource settings in Nigeria, India, and Ethiopia. The IDEAS team includes 20 research and professional support staff, living in Abuja, Addis Ababa, London, and New Delhi, who have been working since 2010 with the Bill & Melinda Gates Foundation (the foundation) and with the foundation’s implementation partners

    Determination of muon momentum in the MicroBooNE LArTPC using an improved model of multiple Coulomb scattering

    Full text link
    We discuss a technique for measuring a charged particle's momentum by means of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time projection chamber (LArTPC). This method does not require the full particle ionization track to be contained inside of the detector volume as other track momentum reconstruction methods do (range-based momentum reconstruction and calorimetric momentum reconstruction). We motivate use of this technique, describe a tuning of the underlying phenomenological formula, quantify its performance on fully contained beam-neutrino-induced muon tracks both in simulation and in data, and quantify its performance on exiting muon tracks in simulation. Using simulation, we have shown that the standard Highland formula should be re-tuned specifically for scattering in liquid argon, which significantly improves the bias and resolution of the momentum measurement. With the tuned formula, we find agreement between data and simulation for contained tracks, with a small bias in the momentum reconstruction and with resolutions that vary as a function of track length, improving from about 10% for the shortest (one meter long) tracks to 5% for longer (several meter) tracks. For simulated exiting muons with at least one meter of track contained, we find a similarly small bias, and a resolution which is less than 15% for muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first estimate of the MCS momentum measurement capabilities of MicroBooNE for high momentum exiting tracks

    Noise Characterization and Filtering in the MicroBooNE Liquid Argon TPC

    Full text link
    The low-noise operation of readout electronics in a liquid argon time projection chamber (LArTPC) is critical to properly extract the distribution of ionization charge deposited on the wire planes of the TPC, especially for the induction planes. This paper describes the characteristics and mitigation of the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase LArTPC comprises two induction planes and one collection sense wire plane with a total of 8256 wires. Current induced on each TPC wire is amplified and shaped by custom low-power, low-noise ASICs immersed in the liquid argon. The digitization of the signal waveform occurs outside the cryostat. Using data from the first year of MicroBooNE operations, several excess noise sources in the TPC were identified and mitigated. The residual equivalent noise charge (ENC) after noise filtering varies with wire length and is found to be below 400 electrons for the longest wires (4.7 m). The response is consistent with the cold electronics design expectations and is found to be stable with time and uniform over the functioning channels. This noise level is significantly lower than previous experiments utilizing warm front-end electronics.Comment: 36 pages, 20 figure

    Ionization Electron Signal Processing in Single Phase LArTPCs II. Data/Simulation Comparison and Performance in MicroBooNE

    Full text link
    The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.Comment: 54 pages, 36 figures; the first part of this work can be found at arXiv:1802.0870
    corecore