2,108 research outputs found
Initial Results of a Silicon Sensor Irradiation Study for ILC Extreme Forward Calorimetry
Detectors proposed for the International Linear Collider (ILC) incorporate a
tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of
electrons, positrons and photons that emerge from the interaction point of the
collider with angles between 5 and 50 milliradians. For the innermost radius of
this calorimeter, radiation doses at shower-max are expected to reach 100 MRad
per year, primarily due to minimum-ionizing electrons and positrons that arise
in the induced electromagnetic showers of e+e- `beamstrahlung' pairs produced
in the ILC beam-beam interaction. However, radiation damage to calorimeter
sensors may be dominated by hadrons induced by nuclear interactions of shower
photons, which are much more likely to contribute to the non-ionizing energy
loss that has been observed to damage sensors exposed to hadronic radiation. We
report here on the results of SLAC Experiment T-506, for which several
different types of silicon diode sensors were exposed to doses of radiation
induced by showering electrons of energy 3.5-10.6 GeV. By embedding the sensor
under irradiation within a tungsten radiator, the exposure incorporated
hadronic species that would potentially contribute to the degradation of a
sensor mounted in a precision sampling calorimeter. Depending on sensor
technology, efficient charge collection was observed for doses as large as 220
MRad.Comment: Talk presented at the International Workshop on Future Linear
Colliders (LCWS13), Tokyo, Japan, 11-15 November 201
Nanometer-scale patterning and individual current-controlled lithography using multiple scanning probes
Cataloged from PDF version of article.Scanning probe lithography(SPL) is capable of sub-30-nm-patterning resolution and nanometer-scale alignment registration, suggesting it might provide a solution to the semiconductor industry’s lithography challenges. However, SPL throughput is significantly lower than conventional lithography techniques. Low throughput most limits the widespread use of SPL for high resolution patterning applications. This article addresses the speed constraints for reliable patterning of organic resists. Electrons field emitted from a sharp probe tip are used to expose the resist. Finite tip-sample capacitance limits the bandwidth of current-controlled lithography in which the tip-sample voltage bias is varied to maintain a fixed emission current during exposure. We have introduced a capacitance compensation scheme to ensure continuous resist exposure of SAL601 polymerresist at scan speeds up to 1 mm/s. We also demonstrate parallel resist exposure with two tips, where the emission current from each tip is individually controlled. Simultaneous patterning with multiple tips may make SPL a viable technology for high resolution lithography.
© 1999 American Institute of Physic
Anesthesia and cognitive performance in children: No evidence for a causal relationship
* Both authors contributed evenly to the manuscript Recent findings of an association between anesthesia administration in the first three years of life and later learning disabilities have created concerns that anesthesia has neurotoxic effects on synaptogenesis, causing later learning problems. An alternative hypothesis is that those children who are likely to undergo surgery early in life have significant medical problems that are associated with a vulnerability to learning disabilities. These two hypotheses were evaluated in a monozygotic concordant–discordant twin design. Data on anesthesia administration and learning abilities and disabilities were available for 1,143 monozygotic twin pairs (56 % female) from the Netherlands Twin Registry. Parents of the twins reported on anesthesia use before age 3 and again between ages 3 and 12 years. Near age 12, educational achievement and cognitive problems were assessed with standardized tests and teacher ratings. Results showed that twins who were exposed to anesthesia before age 3 had significantly lower educational achievement scores and significantly more cognitive problems than twins not exposed to anesthesia. However, there was one important exception: the unexposed co-twin from discordant pairs did not differ from their exposed cotwin. Thus, there is no evidence for a causal relationship between anesthesia administration and later learning-related outcomes in this sample. Rather, there is evidence for early anesthesia being a marker of an individual’s vulnerability for later learning problems, regardless of their exposure to anesthesia
Conformal Ablative Thermal Protection Systems (CA-TPS) for Venus and Saturn Backshells
The new conformal ablator C-PICA, which was developed under STMD GCD, is an optimal candidate for use on the backshells for high velocity entry vehicles at both Venus and Saturn. The material has been tested at heat fluxes up to 400 Wcm2 in shear and over 1800 Wcm2 and 1.5 atm in stagnation with good results. C-PICA has similar density to PICA, but shows half the thermal penetration and similar recession at the same conditions, allowing for a lighter weight TPS to be flown. This poster for VEXAG will show the progress made in the development of the material and why it should be considered for use
Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)
We report on the results of a radiation campaign with neutrons and protons of
Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes
for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an
active thickness of 50~m were irradiated in steps of roughly 2 up
to a fluence of . As a function of the
fluence, the collected charge and time resolution of the irradiated sensors
will be reported for operation at
Avoiding Catch-22:Validating the PainDETECT in a in a population of patients with chronic pain
BACKGROUND: Neuropathic pain is defined as pain caused by a lesion or disease of the somatosensory nervous system and is a major therapeutic challenge. Several screening tools have been developed to help physicians detect patients with neuropathic pain. These have typically been validated in populations pre-stratified for neuropathic pain, leading to a so called "Catch-22 situation:" "a problematic situation for which the only solution is denied by a circumstance inherent in the problem or by a rule". The validity of screening tools needs to be proven in patients with pain who were not pre-stratified on basis of the target outcome: neuropathic pain or non-neuropathic pain. This study aims to assess the validity of the Dutch PainDETECT (PainDETECT-Dlv) in a large population of patients with chronic pain. METHODS: A cross-sectional multicentre design was used to assess PainDETECT-Dlv validity. Included where patients with low back pain radiating into the leg(s), patients with neck-shoulder-arm pain and patients with pain due to a suspected peripheral nerve damage. Patients' pain was classified as having a neuropathic pain component (yes/no) by two experienced physicians ("gold standard"). Physician opinion based on the Grading System was a secondary comparison. RESULTS: In total, 291 patients were included. Primary analysis was done on patients where both physicians agreed upon the pain classification (n = 228). Compared to the physician's classification, PainDETECT-Dlv had a sensitivity of 80% and specificity of 55%, versus the Grading System it achieved 74 and 46%. CONCLUSION: Despite its internal consistency and test-retest reliability the PainDETECT-Dlv is not an effective screening tool for a neuropathic pain component in a population of patients with chronic pain because of its moderate sensitivity and low specificity. Moreover, the indiscriminate use of the PainDETECT-Dlv as a surrogate for clinical assessment should be avoided in daily clinical practice as well as in (clinical-) research. Catch-22 situations in the validation of screening tools can be prevented by not pre-stratifying the patients on basis of the target outcome before inclusion in a validation study for screening instruments. TRIAL REGISTRATION: The protocol was registered prospectively in the Dutch National Trial Register: NTR 3030
Observations of whistler mode waves with nonlinear parallel electric fields near the dayside magnetic reconnection separatrix by the Magnetospheric Multiscale mission
We show observations from the Magnetospheric Multiscale (MMS) mission of whistler mode waves in the Earth's low-latitude boundary layer (LLBL) during a magnetic reconnection event. The waves propagated obliquely to the magnetic field toward the X line and were confined to the edge of a southward jet in the LLBL. Bipolar parallel electric fields interpreted as electrostatic solitary waves (ESW) are observed intermittently and appear to be in phase with the parallel component of the whistler oscillations. The polarity of the ESWs suggests that if they propagate with the waves, they are electron enhancements as opposed to electron holes. The reduced electron distribution shows a shoulder in the distribution for parallel velocities between 17,000 and 22,000 km/s, which persisted during the interval when ESWs were observed, and is near the phase velocity of the whistlers. This shoulder can drive Langmuir waves, which were observed in the high-frequency parallel electric field data
Chronic non-specific low back pain - sub-groups or a single mechanism?
Copyright 2008 Wand and O'Connell; licensee BioMed Central Ltd.
This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0),
which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Background: Low back pain is a substantial health problem and has subsequently attracted a
considerable amount of research. Clinical trials evaluating the efficacy of a variety of interventions
for chronic non-specific low back pain indicate limited effectiveness for most commonly applied
interventions and approaches.
Discussion: Many clinicians challenge the results of clinical trials as they feel that this lack of
effectiveness is at odds with their clinical experience of managing patients with back pain. A
common explanation for this discrepancy is the perceived heterogeneity of patients with chronic
non-specific low back pain. It is felt that the effects of treatment may be diluted by the application
of a single intervention to a complex, heterogeneous group with diverse treatment needs. This
argument presupposes that current treatment is effective when applied to the correct patient.
An alternative perspective is that the clinical trials are correct and current treatments have limited
efficacy. Preoccupation with sub-grouping may stifle engagement with this view and it is important
that the sub-grouping paradigm is closely examined. This paper argues that there are numerous
problems with the sub-grouping approach and that it may not be an important reason for the
disappointing results of clinical trials. We propose instead that current treatment may be ineffective
because it has been misdirected. Recent evidence that demonstrates changes within the brain in
chronic low back pain sufferers raises the possibility that persistent back pain may be a problem of
cortical reorganisation and degeneration. This perspective offers interesting insights into the
chronic low back pain experience and suggests alternative models of intervention.
Summary: The disappointing results of clinical research are commonly explained by the failure of
researchers to adequately attend to sub-grouping of the chronic non-specific low back pain
population. Alternatively, current approaches may be ineffective and clinicians and researchers may
need to radically rethink the nature of the problem and how it should best be managed
- …
