980 research outputs found

    Spatiotemporal evaluation of EMEP4UK-WRF v4.3 atmospheric chemistry transport simulations of health-related metrics for NO2, O3, PM10 and PM2.5 for 2001-2010

    Get PDF
    This study was motivated by the use in air pollution epidemiology and health burden assessment of data simulated at 5 km  ×  5 km horizontal resolution by the EMEP4UK-WRF v4.3 atmospheric chemistry transport model. Thus the focus of the model–measurement comparison statistics presented here was on the health-relevant metrics of annual and daily means of NO2, O3, PM2. 5, and PM10 (daily maximum 8 h running mean for O3). The comparison was temporally and spatially comprehensive, covering a 10-year period (2 years for PM2. 5) and all non-roadside measurement data from the UK national reference monitor network, which applies consistent operational and QA/QC procedures for each pollutant (44, 47, 24, and 30 sites for NO2, O3, PM2. 5, and PM10, respectively). Two important statistics highlighted in the literature for evaluation of air quality model output against policy (and hence health)-relevant standards – correlation and bias – together with root mean square error, were evaluated by site type, year, month, and day-of-week. Model–measurement statistics were generally better than, or comparable to, values that allow for realistic magnitudes of measurement uncertainties. Temporal correlations of daily concentrations were good for O3, NO2, and PM2. 5 at both rural and urban background sites (median values of r across sites in the range 0.70–0.76 for O3 and NO2, and 0.65–0.69 for PM2. 5), but poorer for PM10 (0.47–0.50). Bias differed between environments, with generally less bias at rural background sites (median normalized mean bias (NMB) values for daily O3 and NO2 of 8 and 11 %, respectively). At urban background sites there was a negative model bias for NO2 (median NMB  =  −29 %) and PM2. 5 (−26 %) and a positive model bias for O3 (26 %). The directions of these biases are consistent with expectations of the effects of averaging primary emissions across the 5 km  ×  5 km model grid in urban areas, compared with monitor locations that are more influenced by these emissions (e.g. closer to traffic sources) than the grid average. The biases are also indicative of potential underestimations of primary NOx and PM emissions in the model, and, for PM, with known omissions in the model of some PM components, e.g. some components of wind-blown dust. There were instances of monthly and weekday/weekend variations in the extent of model–measurement bias. Overall, the greater uniformity in temporal correlation than in bias is strongly indicative that the main driver of model–measurement differences (aside from grid versus monitor spatial representivity) was inaccuracy of model emissions – both in annual totals and in the monthly and day-of-week temporal factors applied in the model to the totals – rather than simulation of atmospheric chemistry and transport processes. Since, in general for epidemiology, capturing correlation is more important than bias, the detailed analyses presented here support the use of data from this model framework in air pollution epidemiology

    A reassuring presence: An evaluation of Bradford District Hospice at Home service

    Get PDF
    Within the United Kingdom, a developing role for primary care services in cancer and palliative care has resulted in an increase in palliative home care teams. The provision of professional care in the home setting seeks to provide necessary services and enhanced choice for patients whose preference is to die at home. A mismatch between patient preference for home death and the actual number of people who died at home was identified within Bradford, the locality of this study. In response to this mismatch, and reflecting the policy environment of wishing to enhance community service provision, the four Primary Care Trusts (PCTs) in the city sought to offer support to patients who wished to remain in their own homes through the final stages of a terminal illness. To offer this support they set up a dedicated hospice at home team. This would provide services and support for patients in achieving a dignified, symptom free and peaceful death, allowing families to maximise time spent together. The aim of the study was to evaluate the Bradford hospice at home service from the perspective of carers, nurses and General Practitioners. Postal questionnaires were sent to carers (n = 289), district nurses (n = 508) and GP's (n = 444) using Bradford's hospice at home service. Resulting quantitative data was analysed using the Statical Package for Social Sciences (SPSS) and qualitative data was analysed using grounded theory techniques. The data from carers, district nurses and GPs provide general support for the Bradford hospice at home service. Carers valued highly the opportunity to 'fulfil a promise' to the individual who wished to be cared for at home. District nurses and GPs cited the positive impact of access to specialist expertise. This was a 'reassuring presence' for primary healthcare teams and offered 'relief of carer anxiety' by providing prompt, accessible and sensitive care. Carers and health professionals welcomed the increased possibility of patients being cared for at home. The study identified the need to focus on improving skill levels of staff and on ensuring continuity of care

    Multisensory information facilitates reaction speed by enlarging activity difference between superior colliculus hemispheres in rats

    Get PDF
    Animals can make faster behavioral responses to multisensory stimuli than to unisensory stimuli. The superior colliculus (SC), which receives multiple inputs from different sensory modalities, is considered to be involved in the initiation of motor responses. However, the mechanism by which multisensory information facilitates motor responses is not yet understood. Here, we demonstrate that multisensory information modulates competition among SC neurons to elicit faster responses. We conducted multiunit recordings from the SC of rats performing a two-alternative spatial discrimination task using auditory and/or visual stimuli. We found that a large population of SC neurons showed direction-selective activity before the onset of movement in response to the stimuli irrespective of stimulation modality. Trial-by-trial correlation analysis showed that the premovement activity of many SC neurons increased with faster reaction speed for the contraversive movement, whereas the premovement activity of another population of neurons decreased with faster reaction speed for the ipsiversive movement. When visual and auditory stimuli were presented simultaneously, the premovement activity of a population of neurons for the contraversive movement was enhanced, whereas the premovement activity of another population of neurons for the ipsiversive movement was depressed. Unilateral inactivation of SC using muscimol prolonged reaction times of contraversive movements, but it shortened those of ipsiversive movements. These findings suggest that the difference in activity between the SC hemispheres regulates the reaction speed of motor responses, and multisensory information enlarges the activity difference resulting in faster responses

    CMB Telescopes and Optical Systems

    Full text link
    The cosmic microwave background radiation (CMB) is now firmly established as a fundamental and essential probe of the geometry, constituents, and birth of the Universe. The CMB is a potent observable because it can be measured with precision and accuracy. Just as importantly, theoretical models of the Universe can predict the characteristics of the CMB to high accuracy, and those predictions can be directly compared to observations. There are multiple aspects associated with making a precise measurement. In this review, we focus on optical components for the instrumentation used to measure the CMB polarization and temperature anisotropy. We begin with an overview of general considerations for CMB observations and discuss common concepts used in the community. We next consider a variety of alternatives available for a designer of a CMB telescope. Our discussion is guided by the ground and balloon-based instruments that have been implemented over the years. In the same vein, we compare the arc-minute resolution Atacama Cosmology Telescope (ACT) and the South Pole Telescope (SPT). CMB interferometers are presented briefly. We conclude with a comparison of the four CMB satellites, Relikt, COBE, WMAP, and Planck, to demonstrate a remarkable evolution in design, sensitivity, resolution, and complexity over the past thirty years.Comment: To appear in: Planets, Stars and Stellar Systems (PSSS), Volume 1: Telescopes and Instrumentatio

    Study of Bc+B_c^+ decays to the K+Kπ+K^+K^-\pi^+ final state and evidence for the decay Bc+χc0π+B_c^+\to\chi_{c0}\pi^+

    Get PDF
    A study of Bc+K+Kπ+B_c^+\to K^+K^-\pi^+ decays is performed for the first time using data corresponding to an integrated luminosity of 3.0 fb1\mathrm{fb}^{-1} collected by the LHCb experiment in pppp collisions at centre-of-mass energies of 77 and 88 TeV. Evidence for the decay Bc+χc0(K+K)π+B_c^+\to\chi_{c0}(\to K^+K^-)\pi^+ is reported with a significance of 4.0 standard deviations, resulting in the measurement of σ(Bc+)σ(B+)×B(Bc+χc0π+)\frac{\sigma(B_c^+)}{\sigma(B^+)}\times\mathcal{B}(B_c^+\to\chi_{c0}\pi^+) to be (9.83.0+3.4(stat)±0.8(syst))×106(9.8^{+3.4}_{-3.0}(\mathrm{stat})\pm 0.8(\mathrm{syst}))\times 10^{-6}. Here B\mathcal{B} denotes a branching fraction while σ(Bc+)\sigma(B_c^+) and σ(B+)\sigma(B^+) are the production cross-sections for Bc+B_c^+ and B+B^+ mesons. An indication of bˉc\bar b c weak annihilation is found for the region m(Kπ+)<1.834GeV ⁣/c2m(K^-\pi^+)<1.834\mathrm{\,Ge\kern -0.1em V\!/}c^2, with a significance of 2.4 standard deviations.Comment: All figures and tables, along with any supplementary material and additional information, are available at https://lhcbproject.web.cern.ch/lhcbproject/Publications/LHCbProjectPublic/LHCb-PAPER-2016-022.html, link to supplemental material inserted in the reference

    Performance of the CMS Cathode Strip Chambers with Cosmic Rays

    Get PDF
    The Cathode Strip Chambers (CSCs) constitute the primary muon tracking device in the CMS endcaps. Their performance has been evaluated using data taken during a cosmic ray run in fall 2008. Measured noise levels are low, with the number of noisy channels well below 1%. Coordinate resolution was measured for all types of chambers, and fall in the range 47 microns to 243 microns. The efficiencies for local charged track triggers, for hit and for segments reconstruction were measured, and are above 99%. The timing resolution per layer is approximately 5 ns

    Development and validation of a questionnaire to measure moral distress in community pharmacists

    Get PDF
    The Author(s) 2016. . This article is published with open access at Springerlink.com This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. Jayne L. Astbury, and Cathal T. Gallagher, 'Development and validation of a questionnaire to measure moral distress in community pharmacists', International Journal of Clinical Pharmacy (2017) Vol 39(1): 156-164, first published online on 22 December 2016, the version of record is available on line via doi: 10.1007/s11096-016-0413-3 Funding for this work was provided by Pharmacy Research UK (PRUK).Background Pharmacists work within a highly-regulated occupational sphere, and are bound by strict legal frameworks and codes of professional conduct. This regulatory environment creates the potential for moral distress to occur due to the limitations it places on acting in congruence with moral judgements. Very little research regarding this phenomenon has been undertaken in pharmacy: thus, prominent research gaps have arisen for the development of a robust tool to measure and quantify moral distress experienced in the profession. Objective The aim of this study was to develop an instrument to measure moral distress in community pharmacists. Setting Community pharmacies in the United Kingdom. Method This study adopted a three-phase exploratory sequential mixed-method design. Three semi-structured focus groups were then conducted to allow pharmacists to identify and explore scenarios that cause moral distress. Each of the identified scenarios were developed into a statement, which was paired with twin seven-point Likert scales to measure the frequency and intensity of the distress, respectively. Content validity, reliability, and construct validity were all tested, and the questionnaire was refined. Main outcome measure The successful development of the valid instrument for use in the United Kingdom. Results This research has led to the development of a valid and reliable instrument to measure moral distress in community pharmacists in the UK. The questionnaire has already been distributed to a large sample of community pharmacists. Conclusion Results from this distribution will be used to inform the formulation of coping strategies for dealing with moral distress.Peer reviewedFinal Published versio

    Unusual misregulation of RNA splicing caused by insertion of a transposable element into the T (Brachyury) locus

    Get PDF
    BACKGROUND: The T(Wis )mutant allele of the Brachyury, or T, gene was created by insertion of an endogenous retrovirus-like early transposon (ETn) element into the exon 7 splice donor consensus sequence of the 8 exon T locus. While the developmental consequences of this disruption have been well characterized, the molecular consequences have not been previously investigated, and it has been assumed that the insertion results in a truncated protein. This study sought to further characterize the mutant T(Wis )allele by investigating the nature of the transcripts produced by insertion of this transposable element. RESULTS: Using an RT-PCR based approach, we have shown that at least 8 different mutant transcripts are produced from the T(Wis )allele. All T(Wis )transcripts bypass the mutated exon 7 splice donor site, such that wild type T transcripts are not produced from the T(Wis )allele. CONCLUSIONS: This result shows an unsuspected misregulation of RNA splicing caused by insertion of a transposable element, that could have more widespread consequences in the genome

    Cystatin C: current position and future prospects.

    Full text link
    Abstract Cystatin C is a low-molecular-weight protein which has been proposed as a marker of renal function that could replace creatinine. Indeed, the concentration of cystatin C is mainly determined by glomerular filtration and is particularly of interest in clinical settings where the relationship between creatinine production and muscle mass impairs the clinical performance of creatinine. Since the last decade, numerous studies have evaluated its potential use in measuring renal function in various populations. More recently, other potential developments for its clinical use have emerged. This review summarises current knowledge about the physiology of cystatin C and about its use as a renal marker, either alone or in equations developed to estimate the glomerular filtration rate. This paper also reviews recent data about the other applications of cystatin C, particularly in cardiology, oncology and clinical pharmacology. Clin Chem Lab Med 2008;46:1664-86

    Observation of Bc+ →j /ψD (∗)K (∗) decays

    Get PDF
    A search for the decays B+c→J/ψD(*)0K+ and B+c→J/ψD(*)+K*0 is performed with data collected at the LHCb experiment corresponding to an integrated luminosity of 3 fb−1. The decays B+c→J/ψ0K+ and B+c→J/ψD*0K+ are observed for the first time, while first evidence is reported for the B+c→JψD*+K*0 and B+c→J/ψD+K*0 decays. The branching fractions of these decays are determined relative to the B+c→J/ψπ+ decay. The B+c mass is measured, using the J/ψD0K+ final state, to be 6274.28±1.40(stat)±0.32(syst) MeV/c2. This is the most precise single measurement of the B+c mass to date
    corecore