126 research outputs found
Presbyopic LASIK using hybrid bi-aspheric micro-monovision ablation profile for presbyopic corneal treatments.
PURPOSE: To evaluate distance and near image quality after hybrid bi-aspheric multifocal central presbyLASIK treatments. DESIGN: Consecutive case series. METHODS: Sixty-four eyes of 32 patients consecutively treated with central presbyLASIK were assessed. The mean age of the patients was 51 ± 3 years with a mean spherical equivalent refraction of -1.08 ± 2.62 diopters (D) and mean astigmatism of 0.52 ± 0.42 D. Monocular corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA), and distance corrected near visual acuity (DCNVA) of nondominant eyes; binocular uncorrected distance visual acuity (UDVA); uncorrected intermediate visual acuity (UIVA); distance corrected intermediate visual acuity (DCIVA); and uncorrected near visual acuity (UNVA) were assessed pre- and postoperatively. Subjective quality of vision and near vision was assessed using the 10-item Rasch-scaled Quality of Vision and Near Activity Visual Questionnaire, respectively. RESULTS: At 1 year postoperatively, 93% of patients achieved 20/20 or better binocular UDVA; 90% and 97% of patients had J2 or better UNVA and UIVA, respectively; 7% lost 2 Snellen lines of CDVA; Strehl ratio reduced by ∼-4% ± 14%. Defocus curves revealed a loss of half a Snellen line at best focus, with no change for intermediate vergence (-1.25 D) and a mean gain of 2 lines for near vergence (-3 D). CONCLUSIONS: Presbyopic treatment using a hybrid bi-aspheric micro-monovision ablation profile is safe and efficacious. The postoperative outcomes indicate improvements in binocular vision at far, intermediate, and near distances with improved contrast sensitivity. A 19% retreatment rate should be considered to increase satisfaction levels, besides a 3% reversal rate
Design considerations for the ideal low vision aid: insights from de-brief interviews following a real-world recording study
PURPOSE: Low Vision Aids (LVAs) can have a transformative impact on people living with sight loss, yet the everyday requirements for developing such devices remain poorly understood and defined. This study systematically explored LVA requirements through a structured de-brief interview following a real-world self-recording study. The purpose of this work was to define the actual needs of those living with sight loss so that low vision services can better address them in future. METHODS: Thirty-two visually impaired volunteers with varying levels of previous LVA experience participated in a de-brief interview centred around a structured questionnaire. The de-brief followed a one-week real-world study during which participants used recoding spectacles to capture and narrate all situations in which they would use a ‘perfect sight aid’. Content and thematic analyses were used to analyse interviews which had the purpose of contextualising these recordings and exploring requirements around psychological, functional and design factors. CONCLUSIONS: There is a substantial opportunity for new LVAs to address visual needs that traditional devices and coping strategies cannot support. Functional, psychological and design factors require careful consideration for future LVAs to be relevant and widely adopted
Everyday visual demands of people with low vision: A mixed methods real-life recording study
Research has demonstrated that low vison aids (LVAs) can have a positive impact on the functional sight of those living with sight loss. Step changes in technology are now enabling new wearable LVAs with greater potential than those available previously. For these novel devices to receive increased acceptance and therefore adoption by those with sight loss, visual task demands have to be understood more clearly in order to enable better alignment between device design and user requirements. The aim of this study was to quantify these requirements. Thirty-two participants aged 18 to 87 wore a spectacle-mounted video camera to capture and narrate all everyday situations in which they would use a “perfect” sight aid during 1 week. Captured scenes were analyzed through categorization and computational image analysis. Results showed large variation in activities and lifestyles. Participants reported no available sight aid or coping strategy for 57% of the recorded activities. Reading made up 49% of all recorded tasks, the other half comprising non-textual information. Overall, 75% of captured activities were performed ad hoc (duration of 0–5 minutes), 78% occurred indoors, 58% occurred at home, 48% were lit by natural light, 68% included the object of interest within reach, and 69% required a single focus plane only. Around half of captured objects of interest had a size of 2 degrees visual angle (2.08 logarithm of the minimum angle of resolution [logMAR]) or smaller. This study highlights the need for a sight aid that can make both textual and non-textual scenes accessible while offering flexibility to accommodate individual lifestyles
Bilateral Sutureless Application of Human Dehydrated Amniotic Membrane with a Specialised Bandage Contact Lens for Moderate-to-Severe Dry Eye Disease: A Prospective Study with 1-Month Follow-Up
Sònia Travé-Huarte, James S Wolffsohn Optometry and Vision Science Research Group, College of Health and Life Sciences, Aston University, Birmingham, UKCorrespondence: Sònia Travé-Huarte, School of Optometry, Aston University, Birmingham, UK, Tel +44 1212044400, Email [email protected]: To assess changes in symptoms and ocular surface signs following a bilateral sutureless treatment of dehydrated amniotic membrane (dAM) under a specialised bandage contact lens (sBCL) in patients with moderate-to-severe dry eye disease (DED).Patients and Methods: In this prospective pre-post interventional study, 35 patients diagnosed with moderate-to-severe DED, with an Ocular Surface Disease Index (OSDI) score > 30 on current treatment, were enrolled. Assessments were conducted at baseline (day − 30), after 30 days run-in with no additional treatment (day 0 – control), and 30 days post sBCL+dAM treatment (day 30 – treatment). Intervention involved two successive bilateral 4-5 day sutureless applications of dAM (17mm diameter, with a 6 mm central aperture, Omnigen® VIEW) under an 18mm sBCL (OmniLenz®). Symptomatology and ocular signs were measured using OSDI, Dry Eye Questionnaire-5 (DEQ-5), Symptom Assessment iN Dry Eye (SANDE), and other ocular surface health indicators including non-invasive breakup time, corneal and conjunctival staining, and lid wiper epitheliopathy length and width (LWE).Results: While symptomatology remained stable during the 30-day no-treatment run-in, 1-month post-dAM treatment, there was a significant reduction in OSDI scores (from 55.8 to 32.3, p< 0.001), DEQ-5 (from 14.6 to 10.0, p< 0.001), SANDE frequency (from 65.2 to 43.6, p< 0.001), and SANDE severity (from 59.8 to 41.1, p< 0.001). Additionally, there was a notable decrease in the width of LWE staining, from grade 2 (50– 75% of the lid wiper) to grade 1 (25– 50% of the lid wiper) (p=0.011).Conclusion: A bilateral 8– 10-day treatment duration with dAM applied with sBCL demonstrated a 31 to 42% improvement in symptomatology and a decrease in ocular surface signs of mechanical stress. This innovative bilateral treatment approach offers a promising treatment modality for patients with refractory moderate-to-severe DED.Keywords: dry eye disease, amniotic membrane, bandage contact len
All soft contact lenses are not created equal
Soft contact lenses that have been prescribed by eye care practitioners are sometimes substituted for alternative lenses by unqualified, unregulated and sometimes even fully regulated lens suppliers, in the mistaken belief that there is essentially no difference between different soft lens types. This review considers the implications of inappropriately substituting soft contact lens types in terms of (a) lens properties: surface treatment, internal wetting agents, material, total diameter, back optic zone radius, thickness, edge profile, back surface design, optical design, power, colour (tint) and ultraviolet protection; and (b) lens usage: wearing modality (daily versus overnight wear) and replacement frequency. Potential aspects of patient dissatisfaction and adverse events when prescribed soft lenses are substituted for lenses with different properties or intended usage are considered. Substitution of 15 of the 16 lens properties considered (i.e. except for back surface design) was found to be related to at least one – and as many as six – potential sources of patient dissatisfaction and adverse ocular events. Contact lens are medical devices which are prescribed and fitted; they should never be substituted for another lens type in the absence of a new prescription further to a full finalised fitting, for the simple reason that all soft contact lenses are not created equal. A substituted lens may have properties that results in undesirable consequences in respect of vision, ocular health, comfort and cosmetic appearance, and may be incompatible with the lifestyle of the patient
Optimising subjective grading of corneal staining in Sjögren's syndrome dry eye disease
Aim: To assess whether smaller increment and regionalised subjective grading improves the repeatability of corneal fluorescein staining assessment, and to determine the neurological approach adopted for subjective grading by practitioners.
Methods: Experienced eye-care practitioners (n = 28, aged 45 ± 12 years), graded 20 full corneal staining images of patients with mild to severe Sjögren's syndrome with the Oxford grading scheme (both in 0.5 and 1.0 increments, globally and in 5 regions), expanded National Eye Institute (NEI) and SICCA Ocular Staining Score (OSS) grading scales in randomised order. This was repeated after 7-10 days. The digital images were also analysed objectively to determine staining dots, area, intensity and location (using ImageJ) for comparison.
Results: The Oxford grading scheme was similar with whole and half unit grading (2.77vs2.81,p = 0.145), but the variability was reduced (0.14vs0.12,p < 0.001). Regional grade was lower (p < 0.001) and more variable (p < 0.001) than global image grading (1.86 ± 0.44 for whole increment grading and 1.90 ± 0.39 for half unit increments). The correlation with global grading was high for both whole (r = 0.928,p < 0.001) and half increment (r = 0.934,p < 0.001) grading. Average grading across participants was associated with particle number and vertical position, with 74.4-80.4% of the linear variance accounted for by the digital image analysis.
Conclusions: Using half unit increments with the Oxford grading scheme improve its sensitivity and repeatability in recording corneal staining. Regional grading doesn't give a comparable score and increased variability. The key neurally extracted features in assigning a subjective staining grade by clinicians were identified as the number of discrete staining locations (particles) and how close to the vertical centre was their spread, across all three scales
Sensitivity of Chaos Measures in Detecting Stress in the Focusing Control Mechanism of the Short-Sighted Eye
yesWhen fixating on a stationary object, the power of the eye’s lens fluctuates. Studies have suggested that changes in these so-called microfluctuations in accommodation may be a factor in the onset and progression of short-sightedness. Like many physiological signals, the fluctuations in the power of the lens exhibit chaotic behaviour. A breakdown or reduction in chaos in physiological systems indicates stress to the system or pathology. The purpose of this study was to determine whether the chaos in fluctuations of the power of the lens changes with refractive error, i.e. how short-sighted a subject is, and/or accommodative demand, i.e. the effective distance of the object that is being viewed. Six emmetropes (EMMs, non-short-sighted), six early-onset myopes (EOMs, onset of short-sightedness before the age of 15), and six late-onset myopes (LOMs, onset of short-sightedness after the age of 15) took part in the study. Accommodative microfluctuations were measured at 22 Hz using an SRW-5000 autorefractor at accommodative demands of 1 D (dioptres), 2 D, and 3 D. Chaos theory analysis was used to determine the embedding lag, embedding dimension, limit of predictability, and Lyapunov exponent. Topological transitivity was also tested for. For comparison, the power spectrum and standard deviation were calculated for each time record. The EMMs had a statistically significant higher Lyapunov exponent than the LOMs ( 0.64±0.330.64±0.33 vs. 0.39±0.20 D/s0.39±0.20 D/s ) and a lower embedding dimension than the LOMs ( 3.28±0.463.28±0.46 vs. 3.67±0.493.67±0.49 ). There was insufficient evidence (non-significant p value) of a difference between EOMs and EMMs or EOMs and LOMs. The majority of time records were topologically transitive. There was insufficient evidence of accommodative demand having an effect. Power spectrum analysis and assessment of the standard deviation of the fluctuations failed to discern differences based on refractive error. Chaos differences in accommodation microfluctuations indicate that the control system for LOMs is under stress in comparison to EMMs. Chaos theory analysis is a more sensitive marker of changes in accommodation microfluctuations than traditional analysis methods
Additional psychometric information and vision-specific questionnaires are available for age-realted macular degeneration
Purpose: To present psychometric information and studies dealing with questionnaires for age-related macular degeneration (AMD) and visually impaired patients in addition to the study by Finger et al. "Quality of life in AMD: a review of available vision-specific psychometric tools". We propose that their literature search should not have focused solely on the specific eye disease AMD. Methods: The literature search was partly replicated (PubMed) by using "visual impairment" instead of "macular degeneration" as free text words. Psychometric information was obtained from the additional studies. Preliminary results from a differential item functioning (DIF) analysis used to examine the relationship between item responses on the Vision-related quality of life Core Measure (VCM1) of AMD patients versus patients with other eye conditions are discussed. Results: Eight studies of visually impaired patient populations, including AMD patients, are discussed, with psychometric information from six vision-specific questionnaires. The VCM1 items did not present DIF, which means that the items were equally interpreted by all patients. Conclusions: The results on DIF and the additional studies presented here confirm that a specific eye disorder is of minor importance in the choice of a vision-specific questionnaire or, in this case, a literature search
TFOS Lifestyle: Impact of nutrition on the ocular surface: TFOS Lifestyle Workshop: Nutrition report
Nutrients, required by human bodies to perform life-sustaining functions, are obtained from the diet. They are broadly classified into macronutrients (carbohydrates, lipids, and proteins), micronutrients (vitamins and minerals) and water. All nutrients serve as a source of energy, provide structural support to the body and/or regulate the chemical processes of the body. Food and drinks also consist of non-nutrients that may be beneficial (e.g., antioxidants) or harmful (e.g., dyes or preservatives added to processed foods) to the body and the ocular surface. There is also a complex interplay between systemic disorders and an individual's nutritional status. Changes in the gut microbiome may lead to alterations at the ocular surface. Poor nutrition may exacerbate select systemic conditions. Similarly, certain systemic conditions may affect the uptake, processing and distribution of nutrients by the body. These disorders may lead to deficiencies in micro- and macro-nutrients that are important in maintaining ocular surface health. Medications used to treat these conditions may also cause ocular surface changes. The prevalence of nutrition-related chronic diseases is climbing worldwide. This report sought to review the evidence supporting the impact of nutrition on the ocular surface, either directly or as a consequence of the chronic diseases that result. To address a key question, a systematic review investigated the effects of intentional food restriction on ocular surface health; of the 25 included studies, most investigated Ramadan fasting (56%), followed by bariatric surgery (16%), anorexia nervosa (16%), but none were judged to be of high quality, with no randomized-controlled trials
- …
