362 research outputs found

    The long and winding road to translation for imaging biomarker development: the case for arterial spin labelling (ASL)

    Get PDF
    Radiology is facing many challenges nowadays, and certainly needs to keep up with the fast pace of developments taking place in this field. This editorial aims at drawing the attention of the reader to the current establishment of quantitative imaging biomarkers, in particular through the efforts of the Quantitative Imaging Biomarker Alliance (QIBA) from the Radiological Society of North America (RSNA), as well as the European Imaging Biomarker Alliance (EIBALL) from the European Society of Radiology (ESR). The case of arterial spin labelling (ASL) is used as an example of the long and winding road to translate a good imaging technique into a clinically relevant imaging biomarker

    SAS: Symmetric Analysis of Z-Spectra, a Method to Evaluate B0 Correction Techniques for CEST Data in Clinical Systems Using Non-Exchanging Phantoms

    Get PDF
    Presentation of a method for the comparison of B0 correction methods. This method is based on non-exchanging phantoms to remove CEST effects. SAS method proposed to inform studies

    Arterial Spin Labeling Perfusion of the Brain: Emerging Clinical Applications

    Get PDF
    Arterial spin labeling (ASL) is a magnetic resonance (MR) imaging technique used to assess cerebral blood flow noninvasively by magnetically labeling inflowing blood. In this article, the main labeling techniques, notably pulsed and pseudocontinuous ASL, as well as emerging clinical applications will be reviewed. In dementia, the pattern of hypoperfusion on ASL images closely matches the established patterns of hypometabolism on fluorine 18 fluorodeoxyglucose (FDG) positron emission tomography (PET) images due to the close coupling of perfusion and metabolism in the brain. This suggests that ASL might be considered as an alternative for FDG, reserving PET to be used for the molecular disease-specific amyloid and tau tracers. In stroke, ASL can be used to assess perfusion alterations both in the acute and the chronic phase. In arteriovenous malformations and dural arteriovenous fistulas, ASL is very sensitive to detect even small degrees of shunting. In epilepsy, ASL can be used to assess the epileptogenic focus, both in peri- and interictal period. In neoplasms, ASL is of particular interest in cases in which gadolinium-based perfusion is contraindicated (eg, allergy, renal impairment) and holds promise in differentiating tumor progression from benign causes of enhancement. Finally, various neurologic and psychiatric diseases including mild traumatic brain injury or posttraumatic stress disorder display alterations on ASL images in the absence of visualized structural changes. In the final part, current limitations and future developments of ASL techniques to improve clinical applicability, such as multiple inversion time ASL sequences to assess alterations of transit time, reproducibility and quantification of cerebral blood flow, and to measure cerebrovascular reserve, will be reviewed

    Sodium (Na) ultra-short echo time imaging in the human brain using a 3D-Cones trajectory

    Get PDF
    Object: Sodium magnetic resonance imaging (Na-MRI) of the brain has shown changes in Na signal as a hallmark of various neurological diseases such as stroke, Alzheimer's disease, Multiple Sclerosis and Huntington's disease. To improve scan times and image quality, we have implemented the 3D-Cones (CN) sequence for in vivo Na brain MRI. Materials and methods: Using signal-to-noise (SNR) as a measurement of sequence performance, CN is compared against more established 3D-radial k-space sampling schemes featuring cylindrical stack-of-stars (SOS) and 3D-spokes kooshball (KB) trajectories, on five healthy volunteers in a clinical setting. Resolution was evaluated by simulating the point-spread-functions (PSFs) and experimental measures on a phantom. Results: All sequences were shown to have a similar SNR arbitrary units (AU) of 6-6.5 in brain white matter, 7-9 in gray matter and 17-18 AU in cerebrospinal fluid. SNR between white and gray matter were significantly different for KB and CN (p = 0.046 and <0.001 respectively), but not for SOS (p = 0.1). Group mean standard deviations were significantly smaller for CN (p = 0.016). Theoretical full-width at half-maximum linewidth of the PSF for CN is broadened by only 0.1, compared to 0.3 and 0.8 pixels for SOS and KB respectively. Actual image resolution is estimated as 8, 9 and 6.3 mm for SOS, KB and CN respectively. Conclusion: The CN sequence provides stronger tissue contrast than both SOS and KB, with more reproducible SNR measurements compared to KB. For CN, a higher true resolution in the same amount of time with no significant trade-off in SNR is achieved. CN is therefore more suitable for Na-MRI in the brain. © 2013 The Author(s)

    Sodium ((23)Na) ultra-short echo time imaging in the human brain using a 3D-Cones trajectory

    Get PDF
    Object: Sodium magnetic resonance imaging ((23)Na-MRI) of the brain has shown changes in (23)Na signal as a hallmark of various neurological diseases such as stroke, Alzheimer's disease, Multiple Sclerosis and Huntington's disease. To improve scan times and image quality, we have implemented the 3D-Cones (CN) sequence for in vivo (23)Na brain MRI. Materials and Methods: Using signal-to-noise (SNR) as a measurement of sequence performance, CN is compared against more established 3D-radial k-space sampling schemes featuring cylindrical stack-of-stars (SOS) and 3D-spokes kooshball (KB) trajectories, on five healthy volunteers in a clinical setting. Resolution was evaluated by simulating the point-spread-functions (PSFs) and experimental measures on a phantom. Results: All sequences were shown to have a similar SNR arbitrary units (AU) of 6–6.5 in brain white matter, 7–9 in gray matter and 17–18 AU in cerebrospinal fluid. SNR between white and gray matter were significantly different for KB and CN (p = 0.046 and\0.001 respectively), but not for SOS (p = 0.1). Group mean standard deviations were significantly smaller for CN (p = 0.016). Theoretical full-width at half-maximum linewidth of the PSF for CN is broadened by only 0.1, compared to 0.3 and 0.8 pixels for SOS and KB respectively. Actual image resolution is estimated as 8, 9 and 6.3 mm for SOS, KB and CN respectively. Conclusion: The CN sequence provides stronger tissue contrast than both SOS and KB, with more reproducible SNR measurements compared to KB. For CN, a higher true resolution in the same amount of time with no significant trade-off in SNR is achieved. CN is therefore more suitable for 23Na-MRI in the brain

    Simulating NIRS and MRS Measurements During Cerebral Hypoxia-Ischaemia in Piglets Using a Computational Model

    Get PDF
    We present a group analysis of the changes in cerebral haemodynamics, and the oxidation state of cytochrome-c-oxidase measured using broadband near-infrared spectroscopy (NIRS) and intracellular pH measured by phosphorous ((31)P) magnetic resonance spectroscopy (MRS) during and after cerebral hypoxia-ischaemia (HI) in 15 piglets. We use a previously published computational model of cerebral metabolism in the piglet [1] to integrate these measurements and simulate HI. We successfully simulate changes in cellular metabolism including shifts in intracellular pH observed in the piglet brain during HI. In this process, we optimise physiological parameters in the model identified through sensitivity analysis (such as the rate of glucose metabolism and intracellular lactate concentration), to fit simulated and measured data. The model fits the data reasonably and suggests a 20 % drop in glucose consumption, a ~65 % increase in lactate concentration and ~35 % drop in the cerebral metabolic rate of oxygen (CMRO₂) during HI

    Regional variation of total sodium concentration in the healthy human brain

    Get PDF

    Pulse sequences for measuring exchange rates between proton species: From unlocalised NMR spectroscopy to chemical exchange saturation transfer imaging

    Get PDF
    Within the field of NMR spectroscopy, the study of chemical exchange processes through saturation transfer techniques has a long history. In the context of MRI, chemical exchange techniques have been adapted to increase the sensitivity of imaging to small fractions of exchangeable protons, including the labile protons of amines, amides and hydroxyls. The MR contrast is generated by frequency-selective irradiation of the labile protons, which results in a reduction of the water signal associated with transfer of the labile protons’ saturated magnetization to the protons of the surrounding free water. The signal intensity depends on the rate of chemical exchange and the concentration of labile protons as well as on the properties of the irradiation field. This methodology is referred to as CEST (chemical exchange saturation transfer) imaging. Applications of CEST include imaging of molecules with short transverse relaxation times and mapping of physiological parameters such as pH, temperature, buffer concentration and chemical composition due to the dependency of this chemical exchange effect on all these parameters. This article aims to describe these effects both theoretically and experimentally. In depth analysis and mathematical modelling are provided for all pulse sequences designed to date to measure the chemical exchange rate. Importantly, it has become clear that the background signal from semi-solid protons and the presence of the Nuclear Overhauser Effect (NOE), either through direct dipole-dipole mechanisms or through exchange-relayed signals, complicates the analysis of CEST effects. Therefore, advanced methods to suppress these confounding factors have been developed, and these are also reviewed. Finally, the experimental work conducted both in vitro and in vivo is discussed and the progress of CEST imaging towards clinical practice is presented
    corecore