63 research outputs found
A Randomized Trial of Electrographic Flow-Guided Redo Ablation for Nonparoxysmal Atrial Fibrillation (FLOW-AF)
Background: Electrographic flow (EGF) mapping enables full spatiotemporal reconstruction of organized wavefront propagation to identify extrapulmonary vein sources of atrial fibrillation (AF). Objectives: FLOW-AF (A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW [EGF] Algorithm Technology [Ablamap Software] to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation) was multicenter, randomized controlled study of EGF mapping to: 1) stratify a nonparoxysmal AF population undergoing redo ablation; 2) guide ablation of these extrapulmonary vein AF sources; and 3) improve AF recurrence outcomes. Methods: FLOW-AF enrolled persistent atrial fibrillation (PerAF)/long-standing PerAF patients undergoing redo ablation at 4 centers. One-minute EGF maps were recorded from standardized biatrial basket positions. Patients with source activity ≥26.5% were randomized 1:1 to PVI + EGF-guided ablation vs PVI only; patients without sources ≥26.5% threshold were not randomized. Follow-up and electrocardiographic monitoring occurred at 3, 6, and 12 months. Results: We enrolled 85 patients (age 65.6 ± 9.3 years, 37% female, 24% long-standing PerAF). Thirty-four (40%) patients had no sources greater than threshold; at least 1 source greater than threshold was present in 46 (60%) (EGF-guided ablation, n = 22; control group, n = 26). Patients with sources were older (68.2 vs 62.6 years; P = 0.005) with higher CHA2DS2-VASc scores (2.8 vs 1.9; P = 0.001). The freedom from safety events was 97.2%, and 95% of EGF-identified sources were successfully ablated. In randomized patients, AF-free survival at 12 months was 68% for EGF-guided ablation vs 17% for the control group (P = 0.042); freedom from AF/atrial tachycardia/atrial flutter at 12 months was 51% vs 14% (P = 0.103), respectively. Conclusions: In nonparoxysmal AF patients undergoing redo ablation, EGF mapping identified AF sources in 60% of patients, and could be successfully ablated in 95%. Compared with PVI alone, PVI + source ablation improved AF-free survival by 51% on an absolute basis.</p
Clinical implication of HLA class I expression in breast cancer
<p>Abstract</p> <p>Background</p> <p>Human leukocyte antigen (HLA)-class I molecules on tumor cells have been regarded as crucial sites where cytotoxic T lymphocytes (CTL) can recognize tumor-specific antigens and are strongly associated with anti-tumor activity. However, the clinical impact of HLA class I expression in breast cancer has not been clarified.</p> <p>Methods</p> <p>A total of 212 breast cancer patients who received curative surgery from 1993 to 2003 were enrolled in the current study. HLA class I expression was examined immunohistochemically using an anti-HLA class I monoclonal antibody. The correlation between HLA class I positivity and clinical factors was analyzed.</p> <p>Results</p> <p>The downregulation of HLA class I expression in breast cancer was observed in 69 patients (32.5%). HLA class I downregulation was significantly associated with nodal involvement (p < 0.05), TNM stage (p < 0.05), lymphatic invasion (p < 0.01), and venous invasion (p < 0.05). Patients with preserved HLA class I had significantly better disease-free interval (DFI) than those with loss of HLA class I (p < 0.05). However, in multivariable analysis, HLA class I was not selected as one of the independent prognostic factors of disease-free interval.</p> <p>Conclusion</p> <p>The examination of HLA class I expression is useful for the prediction of tumor progression and recurrent risk of breast cancer via the antitumor immune system.</p
Safety and Effectiveness of Pulsed Field Ablation for Atrial Fibrillation in Patients With Heart Failure
Background: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF).Objectives: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF.Methods: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively.Results: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P > 0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively).Conclusions: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.</p
Multi-national survey on the methods, efficacy, and safety on the post-approval clinical use of pulsed field ablation (MANIFEST-PF).
AIMS
Pulsed field ablation (PFA) is a novel atrial fibrillation (AF) ablation modality that has demonstrated preferential tissue ablation, including no oesophageal damage, in first-in-human clinical trials. In the MANIFEST-PF survey, we investigated the 'real world' performance of the only approved PFA catheter, including acute effectiveness and safety-in particular, rare oesophageal effects and other unforeseen PFA-related complications.
METHODS AND RESULTS
This retrospective survey included all 24 clinical centres using the pentaspline PFA catheter after regulatory approval. Institution-level data were obtained on patient characteristics, procedure parameters, acute efficacy, and adverse events. With an average of 73 patients treated per centre (range 7-291), full cohort included 1758 patients: mean age 61.6 years (range 19-92), female 34%, first-time ablation 94%, paroxysmal/persistent AF 58/35%. Most procedures employed deep sedation without intubation (82.1%), and 15.1% were discharged same day. Pulmonary vein isolation (PVI) was successful in 99.9% (range 98.9-100%). Procedure time was 65 min (38-215). There were no oesophageal complications or phrenic nerve injuries persisting past hospital discharge. Major complications (1.6%) were pericardial tamponade (0.97%) and stroke (0.4%); one stroke resulted in death (0.06%). Minor complications (3.9%) were primarily vascular (3.3%), but also included transient phrenic nerve paresis (0.46%), and TIA (0.11%). Rare complications included coronary artery spasm, haemoptysis, and dry cough persistent for 6 weeks (0.06% each).
CONCLUSION
In a large cohort of unselected patients, PFA was efficacious for PVI, and expressed a safety profile consistent with preferential tissue ablation. However, the frequency of 'generic' catheter complications (tamponade, stroke) underscores the need for improvement
Highly Luminescent Salts Containing Well-Shielded Lanthanide-Centered Complex Anions and Bulky Imidazolium Countercations
In this paper, we report on the syntheses, structures, and characterization of four molten salts containing imidazolium cations and europium(III)- or terbium(III)-centered complex anions. In the complex anions, the lanthanide centers are wrapped by four pseudodiketonate anionic ligands, which prevent them from contacting with high-frequency oscillators and allow them to show intense characteristic europium(III) or terbium(III) emission, small line widths, high color purity, high quantum yields (30−49%), and long decay times (\u3e2 ms)
Highly Luminescent Salts Containing Well-Shielded Lanthanide-Centered Complex Anions and Bulky Imidazolium Countercations
Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.Peer reviewe
PO-624-01 FIRST-IN-HUMAN CLINICAL EXPERIENCE OF A “SINGLE-SHOT” MAP-AND-ABLATE MULTIELECTRODE SPHERICAL ARRAY PULSED FIELD ABLATION CATHETER TO ISOLATE PULMONARY VEINS
- …
